Abstract
The range of hematological measurements using POCT spans from singular determinations of the hemoglobin (Hb) concentration across blood gas analysis (BGA) of hematological variables like Hb and hematocrit (Hct) up to complete blood counts taken on POCT blood count analyzers. The term “blood count” refers to the differential quantification of erythrocytes (or red blood cells, RBC), leukocytes (white blood cells, WBC) (including a differentiation into granulocytes, lymphocytes and monocytes) and thrombocytes (platelets).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Abbott Point of Care. Hematocrit/Hct and Calculated Hb. Article no. 714178–01Q. 15 August 2016
Barker SJ, Shander A, Ramsay MA (2016) Continuous noninvasive hemoglobin monitoring: A measured response to a critical review. Anesth Analg 122: 565–572
Benjamin JT, Baisden CR (2002) Advances in the physician office laboratory. In: Kost GJ (ed) Principles and practice of point-of-care Testing. Lippincott Williams & Wilkins, Philadelphia, pp 391–406
Briggs C, Kunka S, Pennaneach C, Forbes L, Machin SJ (2003) Performance evaluation of a new compact hematology analyzer, the Sysmex pocH-100i. Lab Hematol 9: 225–233
Despotis GJ, Saleem R, Bigham M, Barnes P (2000) Clinical evaluation of a new, point-of-care hemocytometer. Crit Care Med 28: 1185–1190
Gehring H, Hornberger C, Dibbelt L et al. (2002) Accuracy of point-of-care-testing (POCT) for determining haemoglobin concentrations. Acta Anaesthesiol Scand 46: 980–986
Hinds LE, Brown CL, Clark SJ (2007) Point of care estimation of haemoglobin in neonates. Arch Dis Child Fetal Neonatal Ed 92: F378–F380
Jahr JS, Lurie F, Driessen B, Davis JA, Gosselin R, Gunther RA (2002) The HemoCue, a point of care B-hemoglobin photometer, measures haemoglobin concentrations accurately when mixed in vitro with canine plasma and three hemoglobin-based oxygen carriers (HBOC). Can J Anaesth 49: 243–248
Masimo, Corporation (2009) Technisches Merkblatt, Messungen des Gesamthämoglobins: Genauigkeit von Laborgeräten und Auswirkung physiologischer Variation
McNulty SE, Torjman M, Grodecki W, Marr A, Schieren H (1995) A comparison of four bedside methods of hemoglobin assessment during cardiac surgery. Anesth Analg 81: 1197–1202
Osei-Bimpong A, Jury C, McLean R, Lewis SM (2009) Point-of-care method for total white cell count: an evaluation of the HemoCue WBC device. Int J Lab Hematol 31: 657–64
Paul RI, Badgett JT, Buchino JJ (1994) Evaluation of QBC Autoread performance in an emergency department setting. Pediatr Emerg Care 10: 359–63
Rice MJ, Gravenstein N, Morey TE (2013) Noninvasive hemoglobin monitoring: how accurate is enough? Anesth Analg 117:902–907
Seguin P, Kleiber A, Chanavaz C, Morcet J, Mallédant Y (2011) Determination of capillary hemoglobin levels using the HemoCue system in intensive care patients. J Crit Care 26:423–427
Vanzetti G (1966) An azidemethemoglobin method for hemoglobin determination in blood. J Lab Clin Med 67: 116–26
von Schenck H, Falkensson M, Lundberg (1986) Evaluation of „HemoCue,“ a new device for determining hemoglobin. B Clin Chem 32:526–529
Whisler S, Dahlgren C (2005) Performance evaluation of the Sysmex pocH-100i automated hematology analyzer. Lab Hematol 11: 107–117
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer-Verlag GmbH Germany, part of Springer Nature
About this chapter
Cite this chapter
Kixmüller, D., Junker, R. (2018). Analysis of cellular blood components. In: Luppa, P.B., Junker, R. (eds) Point-of-Care Testing. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-54497-6_7
Download citation
DOI: https://doi.org/10.1007/978-3-662-54497-6_7
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-662-54496-9
Online ISBN: 978-3-662-54497-6
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)