Abstract
Coal-fired-derived flue gas mercury measurement mainly includes Ontario Hydro Method, semicontinuous emission monitor, and Appendix K. The Ontario Hydro Method (OHM) is the standard method of measuring and speciating mercury in flue gas, and its solutions were analyzed using a Leeman Labs Hydra AA. The semicontinuous emission monitor (Hg SCEM) uses a gold trap to collect the mercury from the flue gas before analysis with an atomic fluorescence detector. Appendix K (or EPA method 324) is for the continuous sampling of mercury emissions in combustion flue gas streams with sorbent traps. The resulting leachate is analyzed by a cold vapor atomic fluorescence spectrometer (CVAFS) or by a cold vapor atomic absorption spectrometer (CVAA).
We have investigated the comparison between different mercury emission measurement methods, SCEM and OHM, in a 100 MW boiler with wall-fired low-NOx burners, and found that OHM produced consistently higher levels of oxidized mercury than SCEM and the OHM measured higher levels of elemental mercury than SCEM after the ESP. It is logical to assume that fly ash may play a role in the differing measurement of elemental mercury at sampling locations. Moreover, using OHM data as the denominator does not imply that the OHM data are more accurate than the SCEM data and agreement between the two methods seemed to be dependent on the test location.
We also measured the mercury emissions by OHM, CMM, SCEM, and Appendix K in two plants. The data from two continuous mercury monitors (SCE and CMM) show a good consistency with OHM data during the test. However, there are big discrepancies between the data from Appendix K and that from methods of SCEM, CMM, and OHM. The data of compared measurements between OHM, SCEM, and Appendix K show the same trends, which were consistent with the boiler load trend. The data from two continuous mercury monitors (SCE and CMM) show a good consistency with OHM data during the test. Compared with the testing results, the CMM provided valid and representative HgT data and the little lower Hg0 data than that from the OHM and SCEM during most of the tested time.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Shawn Kellie a, Yufeng Duan a, Yan Cao a (2004) Mercury emissions from a 100-MW wall-fired boiler as measured by semicontinuous mercury monitor and Ontario Hydro Method. Fuel Process Technol 85:487–499
U.S. Environmental Protection Agency (1997) Mercury study report to congress, Volume I, Excessive Summary; Office of Air Quality Planning and Standards and Office of Research and Development, EPA-452/R- 97-003
Varley J (2001) Cleaning up in the coal boom. Mod Power Syst 21:19
Laumb J, Jensen R, Benson S (2000) Information collection request (ICR) for mercury, correlation analysis of coal and power plant data. In: Presented at conference on air quality II, mercury, trace elements, and particulate matter, McKean, Virginia, 19–21 September 2000
Ping L, Jiang W, Pan W-p (2009) Multi-method mercury specification from lignite-fired power plants. Korean J Chem Eng 26:542–547
Laudal DL (2005) MEC2 2nd international expert’s workshop, Ottawa, Canada
Jiang Wu, Yuying Du, Weiguo Pan (2009) Study on different measurement methods of mercury emission in the coal-fired power station. In: 3rd international conference on Bioinformatics and biomedical engineering, 11–13 June 2009. ICBBE 2009, pp 1, 4
U.S. EPA (1998) A study of hazardous air pollution emissions from utility steam generating units, final report to congress. U.S.EPA Office of Air Quality Planning and Standards. U.S. Government Printing Office, Washington, DC, EPA-453/R-98-004a
U.S. EPA (1997) Mercury report to congress, U.S. EPA Office of Air Quality Planning and Standards. U.S. Government Printing Office, Washington, DC, EPA-452/R-97-003
Pavlish JH, Sondreal EA, Mann MD, Olson ES, Galbreath KC, Laudal DL, Benson SA (2003) Status review of mercury control options for coal-fired power plants. Fuel Process Technol 82:89–165
Paul Chu, Ralph Roberson, Dennis Laudal, Lynn Brickett, Wei-Ping Pan. “Long-term” mercury emissions variability from coal-fired power plants. www.netl.doe.gov/coal/E&WR/mercury/pubs/A3-3.pdf
Kellie S, Duan Y, Cao Y (2004) Mercury emissions from a 100-MW wall-fired boiler as measured by semicontinuous mercury monitor and Ontario Hydro Method. Fuel Process Technol 85:487–499
Li YH, Lee CW, Gullett BK (2003) Importance of activated carbon’s oxygen surface functional groups on elemental mercury adsorption. Fuel 82:451–457
Fujiwara N, Fujita Y, Tomura K, Moritomi H et al (2002) Mercury transformations in the exhausts from labscale coal flames. Fuel 81:2045–2052
Gibb WH, Clarke F, Mehta AK (2000) The fate of coal mercury during combustion. Fuel Process Technol 65:365–377
Ping Lu, Jiang Wu, and Wei-ping Pan (2009) Multi-method mercury specification from lignite-fired power plants. Korean J Chem Eng 26:542–547
Chengli Wu, Yan Cao, Zhongbing Dong (2010) Evaluation of mercury speciation and removal through air pollution control devices of a 190 MW boiler. J Environ Sci 22:277–282
Cao Y, Duan YF, Kellie S, Li LC, Xu WB, Riley JT et al (2005) Impact of coal chlorine on mercury speciation and emission from a 100-MW utility boiler with cold-side electrostatic precipitators and low-NOx burners. Energy Fuels 19:842–854
Yan Cao, Bobby Chen, Jiang Wu, Hong Cui, John Smith, Chi-Kuan Chen, Paul Chu, Wei-Ping Pan (2007) Study of mercury oxidation by a selective catalytic reduction catalyst in a pilot-scale slipstream reactor at a utility boiler burning bituminous coal. Energy Fuels 21:145–156
Chen Lei, Duan Yufeng, Zhuo Yuqun, Yang Liguo, Zhang Liang, Yang Xianghua, Yao Qiang et al. (2006) Mercury transformation across particulate control devices in six power plants of China, The co-effect of chlorine and ash composition. Fuel 86:603–610
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2015 Shanghai Jiao Tong University Press, Shanghai and Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Wu, J., Cao, Y., Pan, W., Pan, W. (2015). Coal-Fired-Derived Flue Gas Mercury Measurement. In: Coal Fired Flue Gas Mercury Emission Controls. Energy and Environment Research in China. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-46347-5_3
Download citation
DOI: https://doi.org/10.1007/978-3-662-46347-5_3
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-662-46346-8
Online ISBN: 978-3-662-46347-5
eBook Packages: EnergyEnergy (R0)