Skip to main content

Safety-Relevant Application

  • Chapter
Hydrogen and Fuel Cell
  • 3502 Accesses

Abstract

The air from the fuel cell’s cathode can be used to reduce the oxygen concentration in closed quarters. This is of great valuable to fire protection, since fuel cells achieve the goal of keeping the oxygen concentration permanently low. Stationary fuel cell systems are particularly suited for this purpose, since the cathodic outlet air is produced constantly.

In contrast to conventional fire extinction, reducing oxygen is a preventative type of fire protection.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 119.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 159.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Notes

  1. 1.

    QuattroGeneration is a registered trademark of the company N2telligence GmbH.

  2. 2.

    Available at N2telligence GmbH [1].

References

  1. http://www.n2telligence.com

  2. BFT Cognos: Einführung Feuerlöschtechnik. Jahresfachtagung (2007)

    Google Scholar 

  3. Madsen, C.N., Jensen, G., Holmberg, J.: Hypoxic air venting – fire protection for library collections. In: World Library and Information Congress: 71th IFLA General Conference and Council (2005)

    Google Scholar 

  4. http://www.minimax.de

  5. http://www.wagner.de

  6. Bosch, J.: Lagern ohne Risiko. Gas Aktuell Nr.56

    Google Scholar 

  7. Industrie Report International. Erfolg durch Präzision, Nov 2004

    Google Scholar 

  8. http://www.tis-gdv.de/tis/tagungen/kunst/kunsttagung2011/06_rexfort/inhalt.htm#5

  9. http://www.experton-group.de/research/ict-news-dach/news/article/betrachtung-der-technischen-infrastruktur-in-den-data-centern.html

  10. Albers-Dehnicke, K.: Arbeitsplätze in sauerstoffreduzierter Atmosphäre – Befragung von Betrieben, Betriebsärzten und Beschäftigten zu technischen Sicherheitsvorkehrungen, medizinischen Vorsorgeuntersuchungen sowie Erkrankungen und Beschwerden von Exponierten (2011)

    Google Scholar 

  11. Küpper, Th., Milledge, J.S., Hillebrandt, D., Kubalova, J., Hefti, U., Basnayt, B., Gieseler, U., Schöffl, V.: Arbeiten in Hypoxie. UIAA (2009)

    Google Scholar 

  12. Andreas Westenberger, Airbus, Telefonat am 05.12.2012

    Google Scholar 

  13. Walter, A.: Merkblatt: LUFTDICHTHEITSMESSUNG (BlowerDoor) nach EN 13 829 (2008)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Lars Frahm .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Frahm, L. (2016). Safety-Relevant Application. In: Töpler, J., Lehmann, J. (eds) Hydrogen and Fuel Cell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-44972-1_8

Download citation

  • DOI: https://doi.org/10.1007/978-3-662-44972-1_8

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-662-44971-4

  • Online ISBN: 978-3-662-44972-1

  • eBook Packages: EnergyEnergy (R0)

Publish with us

Policies and ethics