Abstract
Currently available left-heart bypass systems are exceedingly elaborate with regard to both implantation and handling (17). Thus, in patients with cardiogenic shock, these systems are not routinely used, with the exception of occasional postcardiotomy and bridging to transplant-applications (6). Up to now, only intraaortic balloon counter-pulsation (IABP) has gained major clinical relevance in treatment of patients with cardiogenic shock (6,12). Counterpulsation leads to an improvement of cardiac energy balance, reducing left-ventricular (LV) pressure load and increasing coronary perfusion pressure. However, with this technique clinical improvement depends on residual left-ventricular function, and many patients who have ventricular failure refractory to IABP require a more complete form of mechanical support.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Baller D, Hoeft A, Korb H, Wolpers HG, Zipfel J, Hellige G (1981) Basic physiological studies on cardiac pacing with special reference to the optimal mode and rate after cardiac surgery. Thorac Cardiovasc Surgn 29: 168–173
Buckberg GD, Brazier JR, Nelson RL, Goldstein SM, McConnel DH, Cooper N (1977) Studies of the effects of hypothermia on regional myocardial blood flow and metabolism during cardiopulmonary bypass 1. The adequately perfused beating, fibrillating, and arrested heart. J Thorac Cardiovasc Surg 73: 87–94
Frazier OH, Wampler RK, Duncan JM, Dear WE, Macris MP, Parnis SM, Fuqua JM (1990) First human use of the Hemopump, a catheter-mounted ventricular assist device. Ann Thorac Surg 49: 299–304
Hellige G, Uhlig P, Hering JP, Scholz KH, Schröder T, Tebbe U (1990) Effektivität des LV-Assistsystems Hemopump im kardiogenen Schock und bei regionaler Myokardischämie. Anaesthesist 39 (Suppl I): 104
Hering JP, Schröder T, Uhlig P, Scholz KH, Tebbe U, Heilige G (1990) Protektive Wirkung des LV-Assistsystems Hemopump in der Frühphase einer regionalen Myokardischämie. Z Kardiol 79 (Suppl I): 26
Kantrowitz A (1988) Circulatory support — State of the art. Trans Amer Soc Artif Intern Org 34: 445–449
Kebbel U, Hirche HJ (1985) An electromagnetic distance measuring system. Medical Progress through Technology 10: 213–223
Korb H, Hoeft A, Baller D, Wolpers HG, Heilige G, Bretschneider HJ (1984) Quantification of ischemic stress during repeated coronary artery occlusion in the dog — a method for validation of therapeutic effects. II. Reproducibility of the release and uptake of electrolytes and substrates. Basic Res Cardiol 79: 38–48
Korb H, Hoeft A, Böck J, Schneider A, Wolpers H, Hellige G (1986) Verbesserung der regionalen Wandfunktion im peripher-und zenralischämischen Myokard nach Hemmung der Thromboxansynthetase mit UK 38.485. Z Kardiol 75 Suppl 4: 44
Loisance D, Dubois Randé JL, Geschwind H, Merlet P, Deleuze PH, Lellouche D, Okude J, Castaigne A, Cachera JP (1989) Left ventricular support by intraventricular blood pump during high-risk coronary angioplasty. Lancet 1: 561
Merhige ME, Smalling RW, Cassidy D, Barrett R, Wise G, Short J, Wampler RK (1989) Effect of the Hemopump left ventricular assist device on regional myocardial perfusion and function. Circulation 80 (Suppl 3): 158–166
Scholz KH, Saathoff H, Tebbe U (1989) Intraaortale Ballongegenpulsation bei akutem Myokardinfarkt, ischämischer Linksherzinsuffizienz und therapierefraktärer Angina pectoris. Dtsch med Wschr 114: 1821–1827
Scholz KH, Tebbe U, Chemnitius M, Kreuzer H, Schröder T, Hering HP, Uhlig P, Heilige G, Autschbach R, Dalichau H (1990) Transfemoral placement of the left ventricular assist device Hemopump during mechanical resuscitation. Thorac Cardiovasc Surgn 38: 69–72
Scholz KH, Schröder T, Tebbe U, Hering JP, Uhlig P, Kreuzer H, Heilige G (1990) Einsatz des linksventrikulären Assist-Systems Hemopump bei experimentellem Kammerflimmern. Z Kardiol 79 (Suppl 2): 45
Scholz KH, Tebbe U, Sold G, Schröder T, Hering JP, Heilige G, Autschbach R, Ruschewski W, Dalichau H, Kreuzer H (1990) Erste klinische Erfahrungen mit dem transfemoral plazierbaren linksventriculären Assist-System Hemopump. Intensivmed 27: 491–497
Uhlig P, Hering JP, Schröder T, Scholz KH, Ruschewski W, Tebbe U, Heilige G (1990) Protektive Wirkung des LV Assistsystems Hemopump im kardiogenen Schock und in der Frühphase einer regionalen Myokardischämie. Thorac Cardiovasc Surgn 38 (Suppl 1 ): 58, 117
Unger F (1989) Assisted Circulation 3. Springer, Berlin, Heidelberg, New York, Tokyo
Vatner SF (1980) Correlation between acute reductions in myocardial blood flow and function in consciuos dogs. Circ Res 47: 201–207
Wampler RK, Maise JC, Frazier OH, Olsen DB (1988) In vivo evaluation of a peripheral vascular-access axial-flow blood pump. Trans Amer Soc Artif Intern Org 34: 450–455
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1991 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Scholz, K.H. et al. (1991). Effect of the Hemopump in cardiogenic shock and in the early stage of regional myocardial ischemia. In: Flameng, W. (eds) Temporary Cardiac Assist with an Axial Pump System. Steinkopff, Heidelberg. https://doi.org/10.1007/978-3-662-10284-8_3
Download citation
DOI: https://doi.org/10.1007/978-3-662-10284-8_3
Publisher Name: Steinkopff, Heidelberg
Print ISBN: 978-3-7985-0906-1
Online ISBN: 978-3-662-10284-8
eBook Packages: Springer Book Archive