Abstract
The authors have been involved in the clinical testing, verification and use of the P-II and P-III “pressurometers” from their earliest days. One of the authors is in the NASA space program and as part of our investigation of the behavior of normal blood pressure in a variety of circumstances, made a series of recordings while flying high performance jet AirCraft A/C and for comparison, while a passenger in civil transport A/C. He also made a series of recordings during space flight on the NASA Shuttle. Excerpts from these are shown to illustrate an individual’s BP response to the aerospace environment.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
v. Diringshofen H and Belonoschkin B: Experimentelle Untersuchungen über den Einfluß hoher Beschleunigungen auf den Blutdruck des Menschen. Z. Biologie 93: 1 (1932).
v. Diringshofen H and Diringshofen B: Elektrokardiographie, Blutdruckschreibung und Pneumotacographie im Motorfluge. Acta Aerophysiologica 6: 48 (1933).
McFarland RA and Edwards HT: The Effects of Prolonged Exposures to Altitudes of 8,000 to 12,000 Feet During Trans Pacific Flights. J. of Aviat Med 8: 156 (1938).
Kirsch RE: A Physiological Study of Aviators During Combat Flying. J. of Aviat Med 16: 376 (1945).
Roman JA: Cardiorespiratory Function Inflight. J. of Aerospace Med 34: 322 (1963).
NASA SP-4003: Space Medicine in Project Mercury. U.S.G.P.O. (1965).
NASA SP-121: Gemini Mid-Program Conference. U.S.G.P.O. (1966).
NASA SP-377: Biomedical Results of Skylab. U.S.G.P.O. (1973).
Ramacci CA et al: Esperienze di Sfig Momanometria Automatica su Piloti Militari in Volo. Ri-vista D Medicina Aeronatica e Spaziale 44: 230 (1980).
Pickering GW: High Blood Pressure. J. and A. Churchill (London (1968)).
Roman J: Risk and Responsibility as Factors Affecting Heart Rate in Test Pilots. Aerospace Medicine 36: 518 (1965).
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1984 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Thornton, W., Wallace, J. (1984). Aerospace applications of ambulatory blood pressure monitoring. In: Weber, M.A., Drayer, J.I.M. (eds) Ambulatory Blood Pressure Monitoring. Steinkopff, Heidelberg. https://doi.org/10.1007/978-3-662-05685-1_14
Download citation
DOI: https://doi.org/10.1007/978-3-662-05685-1_14
Publisher Name: Steinkopff, Heidelberg
Print ISBN: 978-3-662-05687-5
Online ISBN: 978-3-662-05685-1
eBook Packages: Springer Book Archive