Abstract
The γ-ray emitting isotopes like radium 226, cobalt 60, iridium 192, and cesium 137 are used with intracavitary afterloading techniques. Though their physical parameters are quite different (Table 1), the isodose distribution does not change very much if therapy-relevant distances of 1–5 cm are respected. The dose decrease around a point source in water for the above-named isotopes, with small deviations, follows the inverse square law and is therefore independent of isotope and photon energy. This results from a nearly complete compensation of absorption by scattering in the vicinity of the source. Depending on the isotope, the correction F(r) for absorption and scattering up to distances of 5 cm ranges between 0% and 8% (Fig. 1) (Dutreix et al. 1982; Young 1983; Meisberger et al. 1968; Meli et al. 1988).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Bates TD, Berry RJ (1980) High-dose-rate afterloading in the treatment of cancer of the uterus. Br J Radiol [Special Rep] 17
Busch M (1978) Die Messung der Strahlenbelastung von Blase und Rektum bei der gynäkologischen Kontakttherapie. Strahlentherapie 154: 681–685
Coltart RS, Nethersell ABW, Thoma S, Dixon AV (1987) A CT based dosimetry system for intracavitary therapy in carcinoma of the cervix. Radiother Oncol 10: 295–305
Crook JM, Esche BA, Isturiz CCJ, Sentenac I, Horiot JC (1987) Dose-volume analysis and the prevention of radiation sequelae in cervical cancer. Radiother Oncol 8: 321–332
Dale RG (1980) Dosimetry of the Charing Cross Cathetron. Br J Radiol [Special Rep] 17: 38–42
Dutreix A, Marinello G, Wambersie A (1982) Dosimétrie en curiethérapie. Masson, Paris
Glaser FH, Grimm D, Hänsgen G, Rauh G, Schuchardt V (1985) Klinische Erfahrungen bei der AfterloadingKurzeittherapie im Vergleich zur konventionellen Brachytherapie bei der Behandlung gynäkologischer Tumoren. Strahlentherapie 161: 459–475
Himmelmann A, Ragnhult I (1983) High dose-rate after-loading treatment in carcinoma of the uterine cervix using an individual planning and reconstruction system. Acta Radiol [Oncol] (Stockh) 22: 263–271
Himmelmann A, Karlstedt K, Ragnhult I (1980) Early experience with high dose-rate (Ralstron) treatment in Göteborg. Br J Radiol [Special Rep] 17: 106–110
Himmelmann A, Bjurstam N, Ragnhult I (1983) Computed tomography of the cervix and distances to the bladder and rectum in intracavitary radiation treatment of gyneological cancer. Strahlentherapie 159: 198–202
International Commission on Radiation Units and Measurements (ICRU) (1985) Dose and volume specification for reporting intracavitary therapy in gyneology. ICRU, Bethesda (Report no 38 )
Kuipers T, Visser AG (1986) Technical aspects of bladder dosimetry in intracavitary irradiation of cervix carcinoma. Radiother Oncol 7: 7–12
Mak ACA, van’t Riet A, Ypma AFGM, Veen RE, van Slooten FHS (1987) Dose determination in bladder and rectum during intracavitary irradiation of cervix carcinoma. Radiother Oncol 10: 97–100
Meisberger LL, Keller RJ, Shalek RI (1968) The effective attenuation in water of the gamma rays of gold-198, iridium-192, cesium-137, radium-226 and cobalt-60. Radiology 90: 953–957
Meli JA, Meigooni AS, Nath R (1988) On the choice of phantom material for dosimetry of Ir–192 sources. Int J Radiat Oncol Biol Phys 14–587–594
Planskoy B, Lim A (1980) Cathetron dosimetry at the Middlesex Hospital, London. Br J. Radiol [Special Rep] 17: 45–49
Snelling MD, Lambert HE, Yarnold L (1980) Clinical results and complications following treatment of carcinoma of the cervix and endometrium using Cathetron at Middlesex Hospital. Br J Radiol [Special Rep] 17: 33–37
Thesen N (1985) Bestrahlungstechnik, Dokumentation und individuelle Dosimetrie bei der intrakavitären KurzzeitAfterloadingtherapie. Strahlentherapie 161: 476–486
Ward AJ, Stubbs B, Dixon B, Firth LA (1980) A shedule of radiotherapy, including the use of the Cathetron for advanced carcinoma of the cervix. Br J Radiol [Special Rep] 17: 17–23
Young ME (1983) Radiological physics, 3rd edn. Lewis London
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1991 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Thesen, N. (1991). Intracavitary High Dose Rate Afterloading Therapy with Iridium-192: Basic Physical Measurements, Dosimetry, and Localisation. In: Sauer, R. (eds) Interventional Radiation Therapy. Medical Radiology. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-84163-7_37
Download citation
DOI: https://doi.org/10.1007/978-3-642-84163-7_37
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-84165-1
Online ISBN: 978-3-642-84163-7
eBook Packages: Springer Book Archive