Advertisement

Determination of Plasma Volume by Indocyanine Green

  • H. Schad
  • M. Haider
  • H. Brechtelsbauer
  • A. Bernhard-Abt
Conference paper

Abstract

The knowledge of the actual plasma volume is important in the treatment of patients, as well as in clinical research and in experimental studies. The determination is usually performed by the indicator dilution technique with Evans blue, which had been introduced already in the thirties by Gibson and Evans [13] and Gregersen and coworkers [16]. This method, however, is rather time consuming and the number of determinations is limited due to the rather slow elimination of the dye from the circulation and the resulting increase in “background”. Some years ago, the use of radioiodinated albumin was propagated, but this indicator has become obsolete. The advantages of radioalbumin are small, as compared to Evans blue, repetitive determinations are also limited due to the accumulating “background”, but patients are exposed to radiation, and the use of radioactivity should be limited to the indispensable minimum.

Keywords

Plasma Volume Indocyanine Green Evans Blue Disappearance Rate Indicator Dilution Technique 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Allen TH, Pallavicini C, Gregersen MI (1953) Simultaneous measurement of plasma volume with hemoglobin and with T-1824. Am J Physiol 175: 236–239PubMedGoogle Scholar
  2. 2.
    Baker KJ (1966) Binding of sulfobromophthalein (BSP) sodium and indocyanine green (ICG) by plasma alpha-1 lipoproteins. Proc Soc Exp Biol Med 122: 957–963PubMedGoogle Scholar
  3. 3.
    Bloombield DA, Khan AMS (1974) Measurement of blood volume and effusion volume. In: Bloomfield DA (Ed) Dye curves: the theory and practice of indicator dilution. University Park Press, Baltimore, pp 231–243Google Scholar
  4. 4.
    Bonach H, Cornelius CE (1964) Indocyanine green clearance — A liver function test for the dog. Am J Vet Res 25: 254–256Google Scholar
  5. 5.
    Bradley EC, Barr JW (1968) Determination of blood volume using indocyanine green dye. Life Sci 7: 1001–1007PubMedCrossRefGoogle Scholar
  6. 6.
    Butz A (1982) Das Verhalten des Plasmavolumens nach schwerem Trauma und seine Beziehung zur Kreatinin-Clearance. Inaugural Dissertation MunchenGoogle Scholar
  7. 7.
    Center SA, Bunch SE, Baldwin BH, Hornbuckle WE, Tennant BC (1983) Comparison of sulfobromophthalein and indocyanine green clearances in the dog. Am J Vet Res 44: 722–726PubMedGoogle Scholar
  8. 8.
    Cherrick GR, Stein SW, Leevy CM, Davidson CS (1960) indocyanine green: observations on its physical properties, plasma decay, and hepatic extraction. J Clin Invest 39: 592–600PubMedCrossRefGoogle Scholar
  9. 9.
    Dittmer DS (1959) Handbook of circulation. Natl Acad Sci Natl Res Council Saunders, PhiladelphiaGoogle Scholar
  10. 10.
    Finsterer U, Prucksunand P, Brechtelsbauer H (1973) Critical evaluation of methods for determination of blood volume in dog. Pflugers Arch 341: 62–72Google Scholar
  11. 11.
    Fox IJ, Wood EH (1960) Indocyanine green: physical and physiological properties. Proc Staff Meet Mayo Clin 35: 732–744PubMedGoogle Scholar
  12. 12.
    Freinkel N, Schreiner GE, Athens JW, Hiatt CW, Breese S (1954) Artifactual difference in the distribution of T-1824 and I-131 labeled albumin resulting from mixing prior to administration. J Lab Clin Med 43: 215–226PubMedGoogle Scholar
  13. 13.
    Gibson JG, Evans WA (1937) Clinical studies of the blood volume: application of a method employing the azo dye Evans blue and the spectrophotometer. J Clin Invest 16: 301–316PubMedCrossRefGoogle Scholar
  14. 14.
    Gilmore IT, Marigold JH, Thompson RPH (1982) Half-life time of clearance of indocyanine green in patients with liver disease. Hepatogastroenterol 29: 55–57Google Scholar
  15. 15.
    Gregersen MI, Boyden AA, Allison JB (1950) Direct comparison in dogs of plasma volume measured with T-1824 and with antigen. Am J Physiol 163: 517–528PubMedGoogle Scholar
  16. 16.
    Gregersen MI, Gibson JG, Stead EA (1935) Plasma volume determinaton with dyes; errors in colorimetry; use of the blue dye T-1824. Am J Physiol 133: 54–55Google Scholar
  17. 17.
    Gregersen MI, Rawson RA (1959) Bood volume. Physiol Rev 39: 307–342PubMedGoogle Scholar
  18. 18.
    Hunton DB, Bollmann JL, Hoffman HN (1960) Studies of hepatic function with indocyanine green. Gastroenterology 39: 713–724PubMedGoogle Scholar
  19. 19.
    Kholoussy MA, Pollack D, Matsumoto T (1984) Prognostic significance of indocyanine green clearance in critically ill patients. Crit Care Med 12: 115–116PubMedCrossRefGoogle Scholar
  20. 20.
    Kochsiek K (1969) Vergleichende formanalytische Untersuchungen zwischen Thermodilutions-und Farbstoffverdunnungskurven. In: Kramer K, Kirchhoff H-W (Eds) Anwendung densitometrischer, thermischer und radiologischer Methoden in der Klinik. Georg Thieme, Stuttgart, pp 25–37Google Scholar
  21. 21.
    Kuntz HD, Meessen D, May B (1982) Hepatische Elimination von Indocyaningrün und Antipyrin bei Patienten mit chronischer Lebererkrankung. Med Welt 33: 17/909–18/910Google Scholar
  22. 22.
    Lawson HC (1962) The volume of blood — a critical examination of methods for its measurement. In: Handbook of physiology. Sect 2, Circulation, Vol I Am Physiol Soc, Washington DC, pp 23–49Google Scholar
  23. 23.
    Linderkamp O, Holthausen H, Seifert J, Butenandt I, Riegel KP (1977) Accuracy of blood volume estimation in critically ill children using 125-I-labelled albumin and 51-Cr-labelled red cells. Europ J Pediat 125: 143–151PubMedCrossRefGoogle Scholar
  24. 24.
    Linderkamp O, Mader T, Butenandt O, Riegel KP (1977) Plasma volume estimation in severly ill infants and children using a simplified Evans blue method. Europ J Pediat 125: 135–141PubMedCrossRefGoogle Scholar
  25. 25.
    Martin JF, Mikuecky M, Blaschke TF, Waggoner JG, Vergalla J, Berk PD (1975) Differences between the plasma indocyanine green disappearance rates of normal men and women. Proc Soc Exp Biol Med 150: 612–617PubMedGoogle Scholar
  26. 26.
    Nielsen MH, Nielsen NC (1962) Spectrophotometric determination of Evans blue dye in plasma with individual correction for blank density by a modified Gaeblers method. Scan J Clin Lab Invest 14: 605–617CrossRefGoogle Scholar
  27. 27.
    Rawson RA (1943) The binding of T-1824 and stucturally related diazo dyes by the plasma proteins. Am J Physiol 138: 708–717Google Scholar
  28. 28.
    Reeve EB, Gregerson MI, Allen TH, Sear H (1953) Distribution of cells and plasma in the normal and splenectomized dog and its influence on blood volume estimates with 32-P and T-1824. Am J Physiol 175: 195–203PubMedGoogle Scholar
  29. 29.
    Schultz AL, Hammersten JF, Heller BI, Ebert RV (1953) A critical comparison of the T-1824 dye and iodinated albumin methods for plasma volume measurement. J Clin Invest 32: 107– 112PubMedCrossRefGoogle Scholar
  30. 30.
    Sear H, Allen TH, Gregersen MI (1953) Simultaneous measurement in dogs of plasma volume with I-131 human albumin and T-1824 with comparisons of their long term disappearance from the plasma. Am J Physiol 175: 240–242PubMedGoogle Scholar
  31. 31.
    Seifert J, Jesch F, Klövekorn WP, Meßmer K (1972) Die Blutvolumenbestimmung beim Hund im hämorrhagischen Schock. Res Exp Med 157: 269–271CrossRefGoogle Scholar
  32. 32.
    Seifert J, Meßmer K, Probst J, Brendel W (1980) Das zirkulierende Blutvolumen bei Ratten im hämorrhagischen und spinalen Schock. Anaesthesiologie und Intensivmedizin 125: Kreislaufschock pp 205–209Google Scholar
  33. 33.
    Senn VY, Karlson KE (1958) Methodologic and actual error of plasma volume determination. Surgery 44: 1095–1105PubMedGoogle Scholar
  34. 34.
    Simpson AM, Ezrow L, Sapirstein LA (1954) Measurement of plasma volume with rose Bengal. Am J Physiol 177: 319–324PubMedGoogle Scholar
  35. 35.
    Swan H, Nelson W (1971) Blood volume I: Critique: Spun vs. isotope hematocrit, 125-RIHSA vs. 51-Cr RBC. Ann Surg 173: 481–495PubMedCrossRefGoogle Scholar
  36. 36.
    van Vleet JF, Alberts JO (1968) Evaluation of liver function tests and liver biopsy and experimental carbon tetrachloride intoxication and extrahepatic bile duct obstruction in the dog. Am J Vet Res 29: 2119–2131PubMedGoogle Scholar
  37. 37.
    Wheeler HO, Cranston WI, Meltzer JI (1958) Hepatic uptake and biliary excretion of indocyaninegreen in the dog. Proc Soc Exp Biol Med 99: 11–14PubMedGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 1990

Authors and Affiliations

  • H. Schad
  • M. Haider
  • H. Brechtelsbauer
  • A. Bernhard-Abt

There are no affiliations available

Personalised recommendations