Abstract
The choice of optimal substitute, mechanical or biological, for aortic valve replacement is still discussed (4, 7, 8, 14, 15). The use of fresh, unstented, antibiotic-sterilised allografts (homografts) for replacement of aortic valve, aortic root or for correction of some complex congenital malformations, is emphasized by many authors (4–6, 9, 13–15, 17). The method was introduced into clinical practice in the early 1960s, particularly by Ross and Barratt-Boyes (2, 12). The well documented followup studies demonstrate that the results of allograft implantation are comparable or better than those of mechanical valves (5, 8, 11).
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Al-Janabi N, Ross DN (1973) Enhanced viability of fresh aortic homografts stored in nutrient medium. Cardiovasc Res 7: 813
Barratt-Boyes BG (1964) Homograft aortic valve replacement in aortic incompetence and stenosis. Thorax 19: 131
Bodnar E, Wain WH, Martelli V, Ross DN (1979) Long-term performance of 580 homografts and autograft valves used for aortic valve replacement. J Thorac Cardiovasc Surg 27: 51
Dziatkowiak A, Moll J, Musial W, Tracz W, Zienkiewicz J, Zasionka J, Lesniak K, Oszczygiel S, Tyburska I, Kesiak J (1977) Fresh homogenous aortic valves in treatment of aortic valve diseases (in Polish). Kard Pol 20: 189–199
Dziatkowiak A, Pfitzner R, Sadowski J, Tracz WD, Koziorowska B, Marek Z, Zacny E (1986) Aortic root replacement using antibiotic sterilized “fresh” unstented homografts: modification of annulus reinforcement. In: Bodnar E, Yacoub M (eds) Biologic and bioprosthetic valves. Yorke Medical Books, pp 14–21
Fontan F, Choussat A, Deville C, Doutremopuich C, Coupillaud J, Vosa C (1984) Aortic valve homografts in the surgical treatment of complex cardiac malformations. J Thorac Cardiovasc Surg 87: 649–657
Hammond GL, Geha AS, Kopf GS, Hashim SW (1987) Biological versus mechanical valves. Analysis of 1116 valves inserted in 1012 adult patients with a 4,818 patient-year and a 5,327 valve year follow-up. J Thorac Cardiovasc Surg 93: 182–198
Horstkotte D, Rovelli F (1986) Choosing between mechanical and tissue valves for the treatment of valvular heart disease. In: Horstkotte D, Loogen F (eds) Update in heart valve replacement. Steinkopff-Darmstadt, Springer-New York, pp 15–22
Lau JKH, Robles A, Cheridan A, Ross DN (1984) Surgical treatment of prosthetic endocarditis. Aortic root replacement using a homograft. J Thorac Cardiovasc Surg 87: 712–716
Lillehei CW (1986) The St. Jude Medical prosthetic heart valve. Results from a five year multicenter experience. In: Horstkotte D, Loogen F (eds) Update in heart valve replacement. Steinkopff-Darmstadt, Springer-New York, pp 3–13
Moore CH, Martelli V, Al-Janabi N, Ross DN (1975) Analysis of homograft valve failure in 311 patients followed-up td 10 years. Ann Thorac Surg 3: 274–281
Ross DN (1962) Homograft replacement of the aortic valve. Lancet 2: 487
Saravalli OA, Somerville J, Jefferson KE (1980) Calcification of aortic homografts used for reconstruction of the right ventricular outflow tract. J Thorac Cardiovasc Surg 80: 909–920
Somerville J, Ross DN (1982) Homograft replacement of aortic root woth reimplantation of coronary arteries. Results of one to five years. Br Heart J 47: 473–482
Struck E, Meisner H, Hagl S, Paek S, Sebening F (1986) Preferred use of allografts in the treatment of valvular heart disease. In: Horstkotte D, Loogen F (eds) Update in Heart Valve Replacement. Steinkopff-Darmstadt, Springer-New York, pp 25–29
Thompson R, Yacoub M, Ahmed M, Somerville W, Towers M (1980) The use of “fresh” unstented homograft valves for replacement of the aortic valve. Analysis of 8 years’ experience. J Thorac Cardiovasc Surg 79: 896–903
Tracz M, Seabra-Gomes R, Thompson R, Yacoub R, Yacoub M (1979) Left-ventricular function investigations before and after implantation of homologous aortic valve (in Polish). Kard Pol 22:205–213
Van der Kamp AWM, Visser WJ, van Dongen LM, Nauta J, Galjaard H (1981) Preservation of aortic heart valves with maintenance of cell viability. J Surg Res 30: 47–56
Yacoub M, Kittle CF (1979) Sterilization of valve homografts by antibiotic solution. Circulation 41, suppl 2: 29
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1988 Dr. Dietrich Steinkopff Verlag GmbH & Co. KG, Darmstadt
About this paper
Cite this paper
Dziatkowiak, A.J., Pfitzner, R., Andres, J., Podolec, P., Marek, Z., Zarska, M. (1988). Modified techniques for subcoronary insertion of allografts. In: Yankah, A.C., Hetzer, R., Miller, D.C., Ross, D., Somerville, J., Yacoub, M.H. (eds) Cardiac Valve Allografts 1962–1987. Steinkopff. https://doi.org/10.1007/978-3-642-72420-6_23
Download citation
DOI: https://doi.org/10.1007/978-3-642-72420-6_23
Publisher Name: Steinkopff
Print ISBN: 978-3-642-72422-0
Online ISBN: 978-3-642-72420-6
eBook Packages: Springer Book Archive