Abstract
During recent years various groups (3, 4, 6) have studied the possibility of direct evaluation of intracranial tightness by analyzing the height of the ICP pulse amplitude (Amp) without further invasive procedures. The mathematical model (4, 6) underlying this type of assessment requires either the elastance (E) or the cerebral pulse volume (ΔV) to be constant. As recent reports have shown (3, 4, 6), however, these a priori conditions are only partly fulfilled, implying that a general quantitative relationship between Amp and E cannot be firmly established. Similar results were obtained by a separate group (8) who performed an analysis of the ICP modulations.
Supported by grants from DFG (Br 843/1–1)
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Brawanski, A., Gaab, M.R., Heissler, H.E.: Computer analysis of ICP modulations: Clinical significance and prediction of ICP dynamics. In: Intracranial Pressure V, 186–190 (1983)
Brihaye, J., Frowein, R.A., Loew, F.: Coma scaling. Report on the meeting of the W.F.N.S. Neuro-traumatology committee. J. Neurol. Sci. 10, 215–239 (1970)
Castel, J.P., Cohadon, F.: The pattern of cerebral pulse: Automatic analysis. In: Intracranial Pressure III, 303–307 (1976)
Eijndhoven, J.H.M., Cees, J., Avezaat, J.: Cerebrospinal fluid pulse pressure as parameter of intracranial elastance. In: Wood, J.H. (ed.) Neurobiology of cerebrospinal fluid 2, 643–660. Plenum Publishing Corporation 1983
Gaab, M.R., Knoblich, O.E., Dietrich, K.: Miniaturisierte Methoden zur Überwachung des intrakraniellen Druckes. Techniken und klinische Ergebnisse. Langenbecks Arch. Chir. 350, 13–31 (1979)
Gaab, M.R., Haubitz, I., Brawanski, A., Faulstich, F., Heissler, H.E.: Pressure-volume (P/V)-test and pulse wave (PA)-analysis of ICP. Methods and clinical significance. In: Advances in neurosurgery, Vol. 10, pp. 367–377. Springer, Berlin Heidelberg New York 1981
Guinane, J.E.: Cerebrospinal fluid pulse pressure and brain compliance in adult cats. J. Neurol. 25, 559–564 (1975)
Szewszykowski, J., Sliwka, S., Kunicki, A., Dytko, P.W., Korsak-Sliwka, J.: A fast method of estimating the elastance of the intra-cranial system. J. Neurosurg. 47, 19–26 (1977)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1985 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Brawanski, A., Gaab, M.R., Heißler, H.E. (1985). A Computerized Analysis of ICP for the Determination of Intracranial Tightness: Experimental Results and Clinical Significance. In: Dietz, H., Brock, M., Klinger, M. (eds) Extra-Intracranial Vascular Anastomoses Microsurgery at the Edge of the Tentorium. Advances in Neurosurgery, vol 13. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-70603-5_44
Download citation
DOI: https://doi.org/10.1007/978-3-642-70603-5_44
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-15615-4
Online ISBN: 978-3-642-70603-5
eBook Packages: Springer Book Archive