The Applicability of Fluorescence Indicators to Measure Hydrogen Ion Activities by Optimizing Accuracy and Minimizing the Influence of Ionic Strength

  • N. Opitz
  • D. W. Lübbers

Abstract

pH-sensitive fluorescence indicators can be used for the measurement of hydrogen ion activities [8,10]. To improve the applicability of fluorescence indicators generally, we have developed special fluorescence sensors, optodes, in which the indicator molecules are separated from the medium by a protecting membrane which is permeable for the substance to be measured [2, 3, 5]. Thus, interactions of proteins or colloids of biological fluids with the indicator molecules can be avoided. To eliminate optical interference due to reflection changes, scattering, and non-specific fluorescence, the sensor membrane has to be prepared for optical insulation.

Keywords

Fluores 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Chen RF (1968) Fluorescent pH indicators: Spectral changes of 4-methylumbelliferone. Anal Lett 1 (7): 423–428CrossRefGoogle Scholar
  2. 2.
    Lubbers DW, Opitz N (1975) Die pCO2-/pO2-;Optode: Eine neue pCO2- bzw. p2-Meßsonde zur Messung des pCO2oder pO2 von Gasen und Flüssigkeiten, Z Naturforsch 30c: 532–533Google Scholar
  3. 3.
    Lübbers DW, Opitz N, Speiser PP, Bisson HJ (1977) Nanoencapsulated fluorescence indicator molecules measuring pH and p02 down to submicroscopical regions on the basis of the optode principle. Z Naturforsch 32c: 133–134Google Scholar
  4. 4.
    Nakashima M, Sousa JA, Clapp RC (1972) Spectroscopic species of 4-methylumbelliferone in water and ethanol. Nature Phys Sci 235: 16Google Scholar
  5. 5.
    Opitz N (1976) Messung biologischer Gase und Flüssigkeiten mit Hilfe der quantitativen Fluoreszenzphotometrie mit Indikatoren. Thesis, University of MarburgGoogle Scholar
  6. 6.
    Opitz N, Lübbers DW (1983) Hochauflösende pO2Analyse mit abstimmbaren Fluoreszenzmeßsonden. Biomed Tech (Berlin) 28: 31Google Scholar
  7. 7.
    Opitz N, Lübbers DW(1984) New fluorescence photometrical techniques for simultaneous and continuous measurements of ionic strength and hydrogen ion activities. Sensors and Actuators (in press)Google Scholar
  8. 8.
    Peterson JI, Goldstein SR, Fitzgerald RV (1980) Fiber optic pH probe for physiological use. Anal Chern 52: 864–868CrossRefGoogle Scholar
  9. 9.
    Rauen HM (1964) Biochemisches Taschenbuch, Part 2. Springer, Berlin Göttingen Heidelberg New YorkGoogle Scholar
  10. 10.
    Tageeva SV, Kosheleva GN, Dubrov AP (1971) Determination of hydrogen ion concentration in some biological objects with fluorescent indicators. Tsitologiya 13 (1): 122–125Google Scholar
  11. 11.
    Wolfbeis OS, Fürlinger E, Kroneis H, Marsoner H (1983) Fluorimetric analysis. 1. A study on fluorescent indicators for measuring near neutral-(“physiological”) pH-values. Fresenius Z Anal Chern 314: 577–581CrossRefGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 1985

Authors and Affiliations

  • N. Opitz
  • D. W. Lübbers

There are no affiliations available

Personalised recommendations