Skip to main content

Bedside Estimation of Blood-Flow Rate

  • Chapter
Arteriovenous Hemofiltration
  • 50 Accesses

Abstract

There are two clinical situations which require a rough estimation of the bloodflow rate during continuous arteriovenous hemofiltration (CAVH):

  1. 1.

    Differentiation between various causes of low filtration rate: Capillary thrombosis, partial occlusion of the vascular access, low blood pressure, high colloidosmotic pressure, high hematocrit, low blood-flow rate due to inappropriate components of the set and unknown changes of membrane permeability.

  2. 2.

    Suction-assisted CAVH [3] requires blood-flow rates > 100 ml/min for the use of the Diafilter-20 (Amicon), otherwise the negative pressure will result in a blocking of capillaries by red cell puree with consequent clotting of the extracorporeal circuit. For the clinically experienced it may be sufficient to fill the arterial tubing with saline after occlusion of the arterial three-way valve and to observe the blood-flow velocity through the tubing to the hemofilter. With an internal diameter of the tubing of 4 mm the front of the blood column should move at least 5 cm/s through the tubing after opening the stop cock.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Feigl EO (1974) Physic of the cardiovascular system, In: Ruch TC, Patton HD (eds) Physiology and Biophyscis, vol II. Saunders, Philadelphia, p10

    Google Scholar 

  2. Feigl EO (1974) Measurement of blood pressure and blood flow: Ruch TC, Patton HD (eds Physiology and biophysics, vol II. Saunders, Philadelphia, p23

    Google Scholar 

  3. Kaplan AA, Longnecker RE, Folkert VW (1983) Suction-assisted continuous arteriovenous hemofiltration. Trans Am Soc Artif Inter Organs 29:408–412

    CAS  Google Scholar 

  4. Kramer P, Rosick F, Rosenkranz W, Heillige G, Scheler F (1985) Determinaten der Filtrationsfraktion bei arterio-venoser Hamofiltration. Verh Dtsch Ges Inn Medd 90:983–986

    Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1985 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Kramer, P., Rosenkranz, W. (1985). Bedside Estimation of Blood-Flow Rate. In: Kramer, P. (eds) Arteriovenous Hemofiltration. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-70370-6_18

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-70370-6_18

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-15317-7

  • Online ISBN: 978-3-642-70370-6

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics