Skip to main content

Evaluation of Indices for Respiratory Mechanics from an Automated System

  • Chapter
Computers in Critical Care and Pulmonary Medicine

Abstract

The traditional monitoring of respiratory mechanics in patients treated with ventilators includes airway pressure and expired volume minute by minute (Widemann et al. 1984). Semistatic compliance and resistance can be calculated from these parameters (Jonson et al. 1975). Automatic calculation and presentation of lung mechanics has become possible with the use of bedside monitors. Multipatient systems for automatic calculation of these parameters have been described (Matell et al. 1983: Baehrendtz et al. 1980: Brandt and Frank 1980). Reference values for lung mechanics calculated with the aid of such a system in anesthetized patients without pulmonary disease have been published (Carvalhas 1983). However, the influence of various diseases on monitored respiratory-mechanics parameters has, to our knowledge not been systematically studied. In order to establish the influence of common pulmonary disorders on mechanical variables of the lung, automatic respiratory monitoring was carried out in four well defined groups of patients who could be expected to have different lung-mechanical properties. Sampled variables were examined for inter-group differences. In addition, we wanted to test whether a more complex computer-calculated index gave better diagnostic seperation than conventional parameters.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Baehrendtz S, Hulting J, Matell G, Nygards ME (1980) Clinical evaluation of automated arrhythmia monitoring and its integration with respiratory monitoring in a general computerized information system. In: Nair S (ed) Computers in critical care and pulmonary medicine. Plenum, New York, pp 269–277

    Google Scholar 

  • Brandt HJ, Frank W (1980) Automatisierte Kontinuierliche Ăśberwachung der Respiration. Intensivmedizin 17: 220–6

    Google Scholar 

  • Carvalhas AJB (1983) Relacoes de Ventilacao-Perfusao Pulmonar E Mecanica Respiratoria SOB Anaestesia. Thesis, University of Coimbra, Lisaboa, Portugal

    Google Scholar 

  • Jonson B, Nordström L, Olsson SG, Akerback D (1975) Monitoring of ventilation and lung mechanics during automatic ventilation. A new device., Bull Physiopathol Respir 11: 729–743

    Google Scholar 

  • Matell G, Hulting J, Johansson M, Lindelof B (1983) Computerized monitoring and information processing in the ICU - Attempts at an evaluation. In: Bemmel, Ball, Wigertz (eds) North Holland, Amsterdam, pp 84–87

    Google Scholar 

  • Widemann HP, Matthay MA, Matthay RA (1984) Cardiovascularpulmonary monitoring in the intensive care unit. Chest 4: 537–549

    Article  Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1985 Springer-Verlag Berlin Heridelberg

About this chapter

Cite this chapter

Friberg, B. et al. (1985). Evaluation of Indices for Respiratory Mechanics from an Automated System. In: Osswald, P.M. (eds) Computers in Critical Care and Pulmonary Medicine. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-70068-2_29

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-70068-2_29

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-13840-2

  • Online ISBN: 978-3-642-70068-2

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics