Abstract
The traditional monitoring of respiratory mechanics in patients treated with ventilators includes airway pressure and expired volume minute by minute (Widemann et al. 1984). Semistatic compliance and resistance can be calculated from these parameters (Jonson et al. 1975). Automatic calculation and presentation of lung mechanics has become possible with the use of bedside monitors. Multipatient systems for automatic calculation of these parameters have been described (Matell et al. 1983: Baehrendtz et al. 1980: Brandt and Frank 1980). Reference values for lung mechanics calculated with the aid of such a system in anesthetized patients without pulmonary disease have been published (Carvalhas 1983). However, the influence of various diseases on monitored respiratory-mechanics parameters has, to our knowledge not been systematically studied. In order to establish the influence of common pulmonary disorders on mechanical variables of the lung, automatic respiratory monitoring was carried out in four well defined groups of patients who could be expected to have different lung-mechanical properties. Sampled variables were examined for inter-group differences. In addition, we wanted to test whether a more complex computer-calculated index gave better diagnostic seperation than conventional parameters.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Baehrendtz S, Hulting J, Matell G, Nygards ME (1980) Clinical evaluation of automated arrhythmia monitoring and its integration with respiratory monitoring in a general computerized information system. In: Nair S (ed) Computers in critical care and pulmonary medicine. Plenum, New York, pp 269–277
Brandt HJ, Frank W (1980) Automatisierte Kontinuierliche Überwachung der Respiration. Intensivmedizin 17: 220–6
Carvalhas AJB (1983) Relacoes de Ventilacao-Perfusao Pulmonar E Mecanica Respiratoria SOB Anaestesia. Thesis, University of Coimbra, Lisaboa, Portugal
Jonson B, Nordström L, Olsson SG, Akerback D (1975) Monitoring of ventilation and lung mechanics during automatic ventilation. A new device., Bull Physiopathol Respir 11: 729–743
Matell G, Hulting J, Johansson M, Lindelof B (1983) Computerized monitoring and information processing in the ICU - Attempts at an evaluation. In: Bemmel, Ball, Wigertz (eds) North Holland, Amsterdam, pp 84–87
Widemann HP, Matthay MA, Matthay RA (1984) Cardiovascularpulmonary monitoring in the intensive care unit. Chest 4: 537–549
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1985 Springer-Verlag Berlin Heridelberg
About this chapter
Cite this chapter
Friberg, B. et al. (1985). Evaluation of Indices for Respiratory Mechanics from an Automated System. In: Osswald, P.M. (eds) Computers in Critical Care and Pulmonary Medicine. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-70068-2_29
Download citation
DOI: https://doi.org/10.1007/978-3-642-70068-2_29
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-13840-2
Online ISBN: 978-3-642-70068-2
eBook Packages: Springer Book Archive