Skip to main content

Clinical Application of Telemetric Intracranial Pressure Monitoring

  • Conference paper
Intracranial Pressure IV

Abstract

An implantable intracranial pressure (ICP) sensor for long-term monitoring of epi- or subdural pressures would be very useful. Others have proposed sensor designs, summarized by ZERVAS et al (2). Their major problems have been: drift of calibration; no calibration check in vivo, and non-standardized calibrations. We first proposed a sensor which overcomes these problems by incorporating an internal stop within the sensor, so that the zero-point can be confirmed in vivo (2). We also proposed a pressure-balancing method to determine the pressure calibration of the device in vivo (2). A single-diaphragm version of this sensor is suited for ventricular fluid ICP monitoring (1), and a two-diaphragm version is designed for epidural measurements. Updated clinical results on the latter are described here.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Cosman ER, Zervas NT, Chapman PH, Cosman BJ, Arnold MA (1979) A telemetric pressure sensor for ventricular shunt systems. Surg Neurol 11: 287–294

    PubMed  CAS  Google Scholar 

  2. Zervas NT, Cosman ER, Cosman BJ (1977) A pressure-balanced radio-telemetry system for the measurement of intracranial pressure. J Neurosurg 47:899–911

    Article  PubMed  CAS  Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1980 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Zervas, N.T., Chapman, P.H., Cosman, E.R. (1980). Clinical Application of Telemetric Intracranial Pressure Monitoring. In: Shulman, K., Marmarou, A., Miller, J.D., Becker, D.P., Hochwald, G.M., Brock, M. (eds) Intracranial Pressure IV. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-67543-0_97

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-67543-0_97

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-67545-4

  • Online ISBN: 978-3-642-67543-0

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics