In view of the occasion which honors our friend and colleague, Professor Eric Wetterer, I will go back to the beginnings of the electromagnetic flow meter, i.e., to the middle 1930s when he and I were racing full steam ahead on a collision course toward the same goal, unaware of each other’s existence.
This work was supported in part by USPHS Grant HL 17591, by the Alexander von Humboldt Foundation and Medical Testing Systems, Inc.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Bassenge, E., Holtz, J., Kolin, A.: Induction angiometer studies of venous vasomotion in response to Vasoactive Agents (In preparation).
Cox, P., Arora, H., Kolin, A.: Electromagnetic determination of carotid blood flow in the anesthezioted rat. IEEE Trans. Biomed. Electronics 10, 171–173 (1963)
Gessner, U.: Effects of the vessel wall on electromagnetic flow measurement. Biophys. J. 1, 627–637 (1961)
Holtz, J., Restorff, W. v., Bassenge, E., Kolin, A.: Phasic registration of venous diameter changes in-situ with the induction angiometer. Pflügers Arch, (submitted)
Holtz, J., Bassenge, F., Kolin, A.: Venous Vasomotion in Man in Response to Pharmacological and Sensory Stimuli. (In preparation).
Katz, L.N., Kolin, A.: The flow of blood in the carotid artery of the dog under various circumstances as determined with the elctromagnetic flow meter. Am. J. Physiol. 122, 788–797 (1938)
Kolin, A.: An electromagnetic flow meter. Principle of the method and its application to blood flow measurements. Proc. Soc. Exp. Biol. Med. 35, 53–56 (1936)
Kolin, A.: Electromagnetic rheometry and its application to blood flow measurements. Am. J. Physiol. 122, 797–804 (1938)
Kolin, A.: Electromagnetic Blood Flow Meters. Science, 130, 1088–1097 (1959)
Kolin, A.: Blood flow determination by electromagnetic method. In: Medical Physics. Glasser, O. (ed.). Chicago: Year Bk. Med. 1960, Vol. III, p. 275
Kolin, A.: Evolution of electromagnetic blood flow meters. In: Pathophysiology of Congenital Heart Disease. UCLA Forum Med. Sci. 10, 383–405 (1970)
Kolin, A.: Approaches to Blood Flow Measurement by Means of Electromagnetic Catheter Flow Meters. IEEE Trans. Mag. MAG-6, 308–314 (1970)
Kolin, A.: A New Approach to Electromagnetic Blood Flow Determination by Means of Catheter in an External Magnetic Field. Proc. Natl. Acad, Sci. USA 65, 521–527(1970)
Kolin, A.: Recent trends in approaches to electromagnetic determination of blood flow and outlooks for the future. In: Modern Techniques in the Physiological Sciences. Gross, E., Kaufmann, R., Wetterer, E. (eds.). New York: Acad. Press 1973, p. 81
Kolin, A.: A System for intravascular, radially orientation-independent electromagnetic flow- and diametersensing. Pflügers Arch. 372, 109–111 (1977)
Kolin, A.: An, A.C.: Induction flow meter for measurement of blood flow in intact blood vessels. Proc. Soc. Exp. Biol. Med. 46, 235–239 (1941)
Kolin, A., Kado, R.T.: Miniaturization of the elctromagnetic blood flow meter and its use for the recording of circulatory responses of conscious animals to sensory stimuli. Proc. Natl. Acad. Sci. USA 45,1312–1321 (1959)
Kolin, A., Katz, L.N.: Observation de la vitesse instantanée du sang a l’aide du rhéomètre électromagnétique. Ann. Physiol. Physicochimie Biol. 13, 1022–1025 (1937)
Kolin, A., MacAlpin, R.N., Snow, H.D., Coster, I.R., Stein, J.J.: Dependability of the non-occlusive baseline of the interrupted resonance electromagnetic blood flow meter system. Life Sci. 16, 501–516 (1975)
Kolin, A., MacAlpin, R.N.: Induction angiometer: electromagnetic magnification of microscopic vascular diameter variations in-vivo. Blood Vessels 14, 141–156 (1977)
Kolin, A., MacAlpin, R.N., Steckel, R.J.: Electromagnetic rheo-angiometry: An extension of selective angiography. Am. J. Roentgenol. 130, 13–23 (1978)
Kolin, A., Steele, J.R., Imai, J.S., MacAlpin, R.N.: A constant field interrupted resonance system for percutaneous electromagnetic measurement of blood flow. Proc. Natl. Acad. Sci. USA 71, 1294–1298 (1974)
Kolin, A., Wisshaupt, R.: Single-Coil Coreless Electromagnetic Blood Flow Meters. IEEE Trans. Biomed. Electronics 10, 60–67 (1963)
MacAlpin, R.N., Kolin, A., Stein, J.J.: The external field intravascular electromagnetic flow meter system as applied to standard artériographie catheters and conscious humans. Cathet. Cardiovasc. Diagn. 2, 23–37 (1976)
Mills, C.J.: A catheter tip electromagnetic velocity probe. Phys. Med. Biol. 11, 323–324 (1966)
Mills, C.J., Shillingford, J.P.: A Catheter Tip Electromagnetic Velocity Probe and its Evaluation. Cardiovasc. Res. 1, 263–273 (1967)
Restorff, W.v., Bassenge, E.: Evaluation of a neurogenic rapid coronary dilatation during an excitatory response in conscious dogs. Pflügers Arch. 367,157–164 (1976)
Steckel, R.J., Kolin, A., MacAlpin, R.N., Snow, H.D., Juillard, G.J.F., Tesler, A.S., Metzger, J.: Continuing studies with an intravascular blood flow and vascular diameter sensor: physiologic correlations with radiation protection. Am. J. Roentgenol, (in press)
Wetterer, E.: Eine neue Methode zur Registrierung der Blutgeschwindigkeit am uneröffneten Gefäß. Z. Biol. 98, 26–36 (1937)
Wetterer, E., Deppe, B.: Vergleichende tierexperimentelle Untersuchungen zur physikalischen Schlagvolumenbestimmung. Z. Biol. 100, 437–474 (1941)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1978 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Kolin, A. (1978). New Approaches to Electromagnetic Measurement of Blood Flow and Vasomotion Without Recourse to Surgery. In: Bauer, R.D., Busse, R. (eds) The Arterial System. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-67020-6_12
Download citation
DOI: https://doi.org/10.1007/978-3-642-67020-6_12
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-08897-4
Online ISBN: 978-3-642-67020-6
eBook Packages: Springer Book Archive