Skip to main content

Engineering Concepts of Pacemaker Electrodes

  • Chapter
Engineering in Medicine

Abstract

The whole stimulation system consists of three parts:

  • the pulse generator,

  • the myocardium and

  • the electrodes.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. A.E. Becker, M.J. Becker, D.G. Glendon und J.E. Edwards, “Surface thrombosis and fibrous encapsulation of intravenous pacemaker catheter electrodes”, Circulation 46, 409–412 (1972)

    Google Scholar 

  2. H.J. Bisping, W. Irnich, J. Silny und S. Effert, “The importance of constancy of period in checking implanted pacemakers”, Biomed. Engng. 9, 204–206 (1974)

    Google Scholar 

  3. K.S. Cole, “Membranes, ions, and impulses”, Berkeley, Los Angeles, 1968

    Google Scholar 

  4. P. Doenecke, L. Bette, G. Harbauer, W. Hoffmann, G. Hofmeier und H. Schieffer, “Verminderung der Dislokationshäufigkeit durch Verwendung neuentwickelter transvenöser Schrittmacherelektroden”, Z. Kreislaufforsch. 61, 887–891 (1972)

    Google Scholar 

  5. O. Edhag and H. Lagergren, “Transvenous electrodes in long-term stimulation with cardiac pacing”, Ann. N. Y. Acad. Sci. 167, 761–768 (1969)

    Article  Google Scholar 

  6. D.J. Escher and S. Furman, “Ten years experience with transvenous electrodes”, Cardiac pacing, Procs 14th Int. Symp. Groningen, van Gorcum, Assen 239–243 (1973)

    Google Scholar 

  7. S. Furman, B. Parker, D.J.W. Escher, and N. Solomon, “Endocardial threshold of cardiac response as a function of electrode surface area”, J. Surg. Res. 8, 161–166 (1968)

    Article  Google Scholar 

  8. S. Furman, B. Parker, and D.J.W. Escher, “Decreasing electrode size and increasing efficiency on cardiac stimulation”, J. Surg. Res. 11, 105–110 (1971)

    Article  Google Scholar 

  9. L.A. Geddes, C.P. Da Costa, and G. Wise, “The impedance of stainless-steel electrodes”, Med. biol. Engng. 9, 511–521 (1971)

    Google Scholar 

  10. W. Greatbatch and W.M. Chardack, “Myocardial and endocardiac electrodes for chronic implantation”, Ann. N. Y. Acad. Sci. 148, 234–251 (1968)

    Article  Google Scholar 

  11. W. Greatbatch, B. Pierma, F.D. Shannon, and St.W. Calhoon jr., “Polarisation phenomena relating to physiological electrodes”, Ann. N. Y. Acad. Sci. 167, 722–744 (1969)

    Article  Google Scholar 

  12. D.W. van Heeckeren, J.F. Hogan, W.W.L. Glenn, and M.S. Brooks, “Engineering analysis of pacemaker electrodes”, Ann. N.Y. Acad. Sci. 167, 774–784 (1969)

    Article  Google Scholar 

  13. S.W. Hunter, L. Bolduc, V. Long, and F.W. Quattlebaum, “A new myocardial pacemaker lead”, Chest 63, 430–433 (1973)

    Article  Google Scholar 

  14. W. Irnich, “Der Einfluß der Elektrodengröße auf die Reizschwelle bei der Schrittmacherreizung”, Elektromedizin 14, 175–177 (1969)

    Google Scholar 

  15. W. Irnich, “Berechnung der Lebensdauer von Herzschrittmachern”, Biomed. Technik 16, 205–207 (1971)

    Article  Google Scholar 

  16. W. Irnich, W. Bleifeld und S. Effert, “Permanente transvenöse Elektrostimulation des Herzens mit einer myocardial fixierten Elektrode”, Thoraxchirurgie 20, 440–443 (1972)

    Google Scholar 

  17. W. Irnich, “Considerations in electrode design for permanent pacing”, Cardiac pacing, Procs 14th Int. Symp. Groningen van Gorcum, Assen, 268–274 (1973)

    Google Scholar 

  18. W. Irnich, “Physikalische Überlegungen zur Elektrostimulation”, Biomed. Technik 18, 97–104 (1973)

    Article  Google Scholar 

  19. D. Jaron, S.A. Briller, H.P. Schwan, and D.B. Geselowitz, “Nonlinearity of cardiac pacemaker electrodes”, IEEE Trans. Bio-Med. Engng. 16, 132–138 (1969)

    Article  Google Scholar 

  20. A. Kantowitz, M. Rubenfire, and W. Wajszuk, “Complications of permanent transvenous pacemaker therapy”, Cardiac pacing, Proc$14th Int. Symp. Groningen van Gorcum, Assen, 244–252 (1973)

    Google Scholar 

  21. J.W. Keller, A.J. Gosselin, and J.W. Lister, “Engineering aspects of cardiac pacemaking”, Progr. Cardiovasc. Dis. 14, 447–458 (1972)

    Article  Google Scholar 

  22. J.W. Keller, “Improving pacemaker electrodes”, Cardiac pacing, Proc$14th Int. Symp. Groningen van Gorcum, Assen, 275–278 (1973)

    Google Scholar 

  23. H. Lagergren and C.-J. Westerholm, “Electrodes for cardiac pacing”, Cardiac pacing, Proc$14th Int. Symp. Groningen van Gorcum, Assen, 235–238 (1973)

    Google Scholar 

  24. G. Lewin, G.H. Myers, V. Parsonnet, and I.R. Zucker, “Differential current density electrodes for pacemakers”, Proc. 19th Ann. Conf. Eng. Med. Biol. 8, 165 (1965)

    Google Scholar 

  25. K.A. Mansour and W.H. Fleming, “Initial experience with a sutureless screw-in electrode for cardiac pacing”, Ann. Thoracic Surg. 16, 127–132 (1973)

    Article  Google Scholar 

  26. W. Merx, J. Han, and M.S. Yoon, “Effects of unipolar cathodal and bipolar stimulation on ventricular vulnerability”, Am. J. Cardiol. (in press)

    Google Scholar 

  27. W. Mindt, and Ph. Racine, “Stimulating electrode with low energy consumption”, Med. biol. Engng. 11, 659–660 (1973)

    Google Scholar 

  28. J. Mulch, P. Pahutan, and F.W. Hehrlein, “Erste Erfahrungen mit einer neuen myokardialen Schrittmacherelektrode”, Thoraxchirurgie 22, 113–116 (1974)

    Google Scholar 

  29. -J. Ohm, “Displacement and fracture of pacemaker electrode during physical exertion”, Acta Med. Scand. 192, 33–35 (1972)

    Google Scholar 

  30. V. Parsonnet, I.R. Zucker, and L. Gilbert, “Clinical use of a new transvenous electrode”, Ann. N.Y. Acad. Sci. 167, 756–760 (1969)

    Article  Google Scholar 

  31. W. Porstmann, J. Witte, L. Dressler, M. Schaldach, I. Vogel und H. Warnke, “P wave synchronous pacing using anchored atrial electrode implanted without thoracotomy”, Am. J. Cardiol. 30, 74–76 (1972)

    Article  Google Scholar 

  32. T.A. Preston, “Anodal stimulation as a cause of pacemaker-induced ventricular fibrillation”, Am. Heart J. 86, 366–372 (1973)

    Article  Google Scholar 

  33. K.A. Rosenkranz und M. Schaldach, “Transvenös-endokardiale Vorhofsteuerung”, Dtsch. med. Wschr. 96, 680–686 (1971)

    Google Scholar 

  34. M. Schaldach, “Materials for cardiovascular replacement and artificial organs”, Seminar Biomedical Engineering, University of Miami, Coral Gables, Florida, 1971, Mitteilung des Departements für Biomed. Technik, Friedrich Alexander Universität Erlangen-Nürnberg

    Google Scholar 

  35. M. Schaldach, “New pacemaker electrodes”, Trans. Amer. Soc. Artif. Int. Organs 29, 29–35 (1971)

    Google Scholar 

  36. G. Schmitt und W.H. Hauss, “Tierexperimente mit einem neu entwickelten transvenösen Herzkatheter”, Biomed. Technik 6, 211–212 (1971)

    Article  Google Scholar 

  37. G. Schmitt, H.J. Krupke, L. Backmann und W.H. Nauss, “Klinische Erfahrungen mit einer neu entwickelten Katheter-Elektrode”, Münch. med. Wschr. 24, 1141–1144 (1973)

    Google Scholar 

  38. P.P. Tarjan, “Engineering aspects of implantable cardiac pacemakers”, in: Cardiac Pacing (Ph. Samet editor) Grune and Stratton, New York-London 47–71 (1973)

    Google Scholar 

  39. G.F.O. Tyers, H.A. Torman, and H.C. Hughes, “Comparative studies of “state of the art” and presently used clinical cardiac pacemaker electrodes”, J. Thorax. Cardiovasc. Surg. 67, 849–856 (1974)

    Google Scholar 

  40. J.A. Udall, “Pervenous fixed endocardial pacing: a short-term study in ten dogs”, Curr. Ther. Res. 13, 209–216 (1971)

    Google Scholar 

  41. J.A. Udall, “Pervenous atrial pacing by fixed electrodes”, J.A. M.A. 222, 702–706 (1972)

    Article  Google Scholar 

  42. C.J. Westerholm, “Threshold studies in transvenous cardiac pacemaker treatment”, Scand. J. Thorac. Cardiovasc. Surg. Supp. 8, 1–35 (1971)

    Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1975 Springer-Verlag Berlin-Heidelberg

About this chapter

Cite this chapter

Irnich, W. (1975). Engineering Concepts of Pacemaker Electrodes. In: Schaldach, M., Furman, S. (eds) Engineering in Medicine. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-66187-7_15

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-66187-7_15

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-66189-1

  • Online ISBN: 978-3-642-66187-7

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics