Skip to main content
  • 153 Accesses

Abstract

The central point of the entire d.c. transmission link is the valve. A distinction is made between genuine and non-genuine valves. Genuine valves have a physically determined, definite direction of conduction, whilst the conduction direction of non-genuine valves is determined by external circumstances. The mechanical valve of the contact converter is an example of a non-genuine valve, since the direction of current flow depends on which of the two alternating voltage half-waves coincides with the making of the contact. A non-genuine valve more suited for high-voltage purposes is the spark discharge valve, in which triggering of a spark gap initiates the conduction period. Despite extensive development work which led to the erection of an experimental transmission link, it proved impossible to achieve results which would encourage the introduction of these valves in commercial transmission links. There is therefore no need to discuss this type of valve in greater detail here; instead we shall simply note that so far only genuine valves have led to practical results. This limitation, the existence of which has already formed the basis of our introduction, is regrettable because non-genuine valves have a distinct advantage over genuine valves. The complete valve set according to Fig. 1.5 would have to be made up of only six valves, the change in power direction could be brought about by changing the current direction instead of the voltage direction, and polarity changing of the converter connection, especially in multi-terminal transmission links, would be superfluous resulting in constant voltage system properties in this respect as well.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 1975 Springer-Verlag, Berlin / Heidelberg

About this chapter

Cite this chapter

Uhlmann, E. (1975). Converter Stations. In: Power Transmission by Direct Current. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-66072-6_6

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-66072-6_6

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-66074-0

  • Online ISBN: 978-3-642-66072-6

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics