Abstract
Interventional magnetic resonance imaging (I-MRI) is the use of MR images for biopsy and drainage, and for both guidance and monitoring of minimally invasive therapy (including thermal destruction of tumors). As a result, MRI is rapidly becoming an important tool in the performance of interventional procedures; the medical use of MRI may be expanded from diagnosis only to treatment. However, MRI pulse sequences must be adapted to meet the requirements for: (a) high temporal resolution during biopsy needle insertion, (b) high spatial resolution for accurate needle tip localization, (c) rapid reconstruction/display to achieve near-real-time guidance, and (d) contrast between normal and pathologic tissue and the interventional devices.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Borges A, Villablanca JP, Lufkin RB (1997) MR imaging- guided biopsies in the head and neck region:a comparative evaluation of low field open and high field closed MR systems. Radiology 205 (P):531 (abstract)
Castro DJ, Lufkin RB, Saxton RE, Nyerges A, Soudant J, Layfield LJ, Jabour BA, Ward PH, Kangarloo H (1992) Metastatic head and neck malignancy treated using MRI guided interstitial laser phototherapy:an initial case report. Laryngoscope 102:26–32
Duckwiler G, Lufkin RB, Teresi L, Spickler E, Dion J, Vinuela F, Bentson J, Hanafee W (1989) Head and neck lesions:MR-guided aspiration biopsy. Radiology 170:519–522
Frahm C, Gehl HB, Melchert UH, Weiss HD (1996) Visualization of magnetic resonance-compatible needles at 1.5 and 0.2 Tesla. Cardiovasc Intervent Radiol 19:335–340
Kacl GM, Carls FP, Sailer HF et al (1997) Interactive MR-guided biopsies of the maxilla and the skull base. Radiology 205 (P):531 (abstract)
Lewin JS, Duerk JL, Jain VR, Petersilge CA, Chao CP, Haaga JR (1996) Needle localization in MR-guided biopsy and aspiration:effects of field strength, sequence design, and magnetic field orientation. Am J Roentgenol 166:1337–1345
Lewin JS, Petersilge CA, Hatem SF et al (1998) Interactive MR imaging-guided biopsy and aspiration with a modified clinical C-arm system. Am J Roentgenol 170:1593–1601 Lufkin R, Layfield L (1989) Coaxial needle system of MR- and CT-guided aspiration cytology. J Comput Assist Tomogr 13:1105–1107
Lufkin R, Teresi L, Hanafee W (1987) New needle for MR- guided aspiration cytology of the head and neck. Am J Roentgenol 149:380–382
Lufkin R, Teresi L, Chiu L, Hanafee W (1988) A technique for MR-guided needle placement. Am J Roentgenol 151:193–196
Lufkin RB, Gronemeyer DW, Seibel RM (1997) Interventional MRI:update. Eur Radiol 7:187–200
Mahfouz AE, Rahmouni A, Zylbersztejn C, Mathieu D (1996) MR-guided biopsy using ultrafast Tl- and T2-weighted reordered turbo fast low-angle shot sequences:feasibility and preliminary clinical applications. Am J Roentgenol 167:167–169
Mueller PR, Stark DD, Simeone JF, Saini S, Butch RJ, Edelman RR, Wittenberg J, Ferrucci JTJ (1986) MR-guided aspiration biopsy:needle design and clinical trials. Radiology 161:605–609
Norbash AM, Daniel BL, Butts K et al (1997) Magnetic Resonance Therapy (MRT) guided biopsies in the skull base, suprahyoid neck, and infrahyoid neck. Proceedings of the SMR meeting 1997, p 530 (abstract)
Sinha S, Sinha U, Lufkin R, Hanafee W (1989) Pulse sequence optimization for use with a biopsy needle in MRI. Magn Reson Imaging 7:575–579
Trapp T, Lufkin R, Abemayor E, Layfield L, Hanafee W, Ward P (1989) A new needle and technique for MRI-guided aspiration cytology of the head and neck. Laryngoscope 99:105–108
Vogl TJ, Mack MG, Muller P, Phillip C, Bottcher H, Roggan A, Juergens M, Deimling M, Knobber D, Wust P (1995) Recurrent nasopharyngeal tumors:preliminary clinical results with interventional MR imaging-controlled laser-induced thermotherapy. Radiology 196:725–733
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1999 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Merkle, E.M., Lewin, J.S., Duerk, J.L. (1999). Magnetic Resonance Imaging-Guided Intervention in the Head and Neck. In: Mukherji, S.K., Castelijns, J.A. (eds) Modern Head and Neck Imaging. Medical Radiology. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-59826-5_2
Download citation
DOI: https://doi.org/10.1007/978-3-642-59826-5_2
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-66344-7
Online ISBN: 978-3-642-59826-5
eBook Packages: Springer Book Archive