Abstract
The aim of improving technology in radiotherapy is to close the loop of planning, delivery, and verification. Currently, the most common way to obtain information about the treatment is to image the patient’s treatment volume on portal images. However, more accurate delivery techniques spur the need for improved patient imaging. In consequence, active research is going on in the optimization of current detector technologies combined with the modification of delivery systems. Dual-beam systems [1] and tomotherapy [2] are two approaches to achieve this goal.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Jaffray D A, Drake D G, Moreau M, Martinez A A, and Wong J W 1999 A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets Int. J. Radiat Oncol Biol. Phys. 25 773–789
Olivera G H, Shepard D M, Ruchala K, Aldridge J S, Kapatoes J M, Fitchard E E, Reckwerdt P J, Fang G, Balog J, Zachman J, and Mackie T R 1999 Tomother-apy in Van Dyk J Ed. Modern Technology of Radiation Oncology, (Medical Physics Publishing, Madison, WI, 1999)
Boyer A L, Antonuk L, Fenster A, Van Herk M, Meertens H, Munro P, Reinstein L E, and Wong J 1992 A review of electronic portal imaging devices (EPIDs) Med. Phys. 19 1–16
Ruchala K J, Olivera G H, Schloesser E A, and Mackie T R 1999 Megavoltage CT on a tomotherapy system Phys. Med. Biol. 44 2597–2621
Rogers D W O, Faddegon B A, Ding G X, Ma C-M, We J, and Mackie T R 1995 BEAM: A Monte Carlo code to simulate radiotherapy treatment units Med. Phys. 22 503–524
Kausch C, Schreiber B, Kreuder F, Schmidt R, and Dössel O 1999 Monte Carlo simulations of the imaging performance of metal/phosphor screens used in radiotherapy Med. Phys. 26 2113–2124
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2000 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Keller, H., Glass, M., Olivera, G.H., Maekie, T.R. (2000). Monte-Carlo evaluation of a highly efficient photon detector for tomotherapy. In: Schlegel, W., Bortfeld, T. (eds) The Use of Computers in Radiation Therapy. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-59758-9_55
Download citation
DOI: https://doi.org/10.1007/978-3-642-59758-9_55
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-67176-3
Online ISBN: 978-3-642-59758-9
eBook Packages: Springer Book Archive