Abstract

The aim of improving technology in radiotherapy is to close the loop of planning, delivery, and verification. Currently, the most common way to obtain information about the treatment is to image the patient’s treatment volume on portal images. However, more accurate delivery techniques spur the need for improved patient imaging. In consequence, active research is going on in the optimization of current detector technologies combined with the modification of delivery systems. Dual-beam systems [1] and tomotherapy [2] are two approaches to achieve this goal.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Jaffray D A, Drake D G, Moreau M, Martinez A A, and Wong J W 1999 A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets Int. J. Radiat Oncol Biol. Phys. 25 773–789

    Google Scholar 

  2. Olivera G H, Shepard D M, Ruchala K, Aldridge J S, Kapatoes J M, Fitchard E E, Reckwerdt P J, Fang G, Balog J, Zachman J, and Mackie T R 1999 Tomother-apy in Van Dyk J Ed. Modern Technology of Radiation Oncology, (Medical Physics Publishing, Madison, WI, 1999)

    Google Scholar 

  3. Boyer A L, Antonuk L, Fenster A, Van Herk M, Meertens H, Munro P, Reinstein L E, and Wong J 1992 A review of electronic portal imaging devices (EPIDs) Med. Phys. 19 1–16

    Article  PubMed  CAS  Google Scholar 

  4. Ruchala K J, Olivera G H, Schloesser E A, and Mackie T R 1999 Megavoltage CT on a tomotherapy system Phys. Med. Biol. 44 2597–2621

    Article  PubMed  CAS  Google Scholar 

  5. Rogers D W O, Faddegon B A, Ding G X, Ma C-M, We J, and Mackie T R 1995 BEAM: A Monte Carlo code to simulate radiotherapy treatment units Med. Phys. 22 503–524

    Article  PubMed  CAS  Google Scholar 

  6. Kausch C, Schreiber B, Kreuder F, Schmidt R, and Dössel O 1999 Monte Carlo simulations of the imaging performance of metal/phosphor screens used in radiotherapy Med. Phys. 26 2113–2124

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2000 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Keller, H., Glass, M., Olivera, G.H., Maekie, T.R. (2000). Monte-Carlo evaluation of a highly efficient photon detector for tomotherapy. In: Schlegel, W., Bortfeld, T. (eds) The Use of Computers in Radiation Therapy. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-59758-9_55

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-59758-9_55

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-67176-3

  • Online ISBN: 978-3-642-59758-9

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics