Skip to main content

Simulator Testing of Total Knee Replacements

  • Chapter
  • First Online:
Tribology in Total Hip and Knee Arthroplasty
  • 1286 Accesses

Abstract

The human knee joint is a highly complex system making both the implantation and testing of total knee replacements (TKRs) a very demanding task. The first hydraulic knee simulator was introduced in 1977 [1] followed closely by an ingenious gear-driven mechanical system [2]. Despite the development of TKRs throughout this period, it took another 20 years until the first multi-station wear simulator became available [3]. It is this development that can be regarded as the trigger for standardization and commercialization of TKR wear testing. Unfortunately, there remains an ongoing debate about how best to conduct wear testing of new devices. As a result, there exist two different ISO standards for carrying out wear testing: ISO 14243-1 describes a force-controlled test method, whereas ISO 14243-3 describes a displacement-controlled test method. While both methods accord that the flexion-extension motion of the joint needs to be displacement controlled, the philosophy of anterior-posterior and torsional loads is different: Part 1 of the standard understands anterior-posterior motion of the knee joint as a result of the anterior-posterior load applied, whereas Part 3 describes a predefined anterior-posterior displacement that needs to be generated by the simulator. The same difference between test methods applies to the simulation of torsional motion. Direct comparison to clinical data has revealed an accurate reproduction of the in vivo motions when using the force-controlled test method [4, 5], whereas the displacement-controlled method has yielded certain limitations for constrained implant designs (i.e., tibial post or high conforming designs). However, it is important to note that force-controlled test frames are more complex to design and operate.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Dowson D, Jobbins B, ÓKelly J, Wright V. Chapter 7. A knee joint simulator. In: Evaluation of artificial hip joints. Biological Engineering Society: London; 1977. p. 79–90.

    Google Scholar 

  2. Stallforth H, Ungethuem M. Entwicklung eines Kniegelenksimulators. Arch Orthop Unfall-Chir. 1977;90:343–53.

    Article  CAS  Google Scholar 

  3. Walker PS, Blunn GW, Broome DR, Perry J, Watkins A, Sathasivam S, Dewar ME, Paul JP. A knee simulating machine for performance evaluation of total knee replacements. J Biomech. 1997;30:83–9.

    Article  CAS  PubMed  Google Scholar 

  4. DesJardins JD, Banks SA, Benson LC, Pace T, LaBerge M. A direct comparison of patient and force-controlled simulator total knee replacement kinematics. J Biomech. 2007;40:3458–66.

    Article  PubMed  Google Scholar 

  5. Ngai V, Schwenke T, Wimmer MA. In-vivo kinematics of knee prostheses patients during level walking compared with the ISO force-controlled simulator standard. Proc Inst Mech Eng H. 2009;223:889–96.

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  6. Haider H. Tribological assessment of UHMWPE in the knee. In: Kurtz S, editor. UHMWPE biomaterials handbook. Amsterdam: Elsevier; 2009.

    Google Scholar 

  7. Oral E, Ghali BW, Neils A, Muratoglu OK. A new mechanism of oxidation in ultrahigh molecular weight polyethylene caused by squalene absorption. J Biomed Mater Res. 2012;100B:742–51.

    Article  CAS  Google Scholar 

  8. Papoola O, Yao JQ, Johnson TS, Blanchard CR. Wear, delamination, and fatigue resistance of melt-annealed highly crosslinked UHMWPE cruciate-retaining knee inserts under activities of daily living. J Orthop Res. 2010;28(9):1120–6.

    Article  Google Scholar 

  9. Schwiesau J, Schilling C, Kaddick C, Utzschneider S, Jansson V, Fritz B, Blömer W, Grupp TM. Definition and evaluation of testing scenarios for knee wear simulation under conditions of highly demanding daily activities. Med Eng Phys. 2013;35:591–600.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Christian Kaddick PhD .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 EFORT

About this chapter

Cite this chapter

Kaddick, C. (2014). Simulator Testing of Total Knee Replacements. In: Knahr, K. (eds) Tribology in Total Hip and Knee Arthroplasty. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-45266-6_4

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-45266-6_4

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-45265-9

  • Online ISBN: 978-3-642-45266-6

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics