Skip to main content

Random Segmentation Based Principal Component Analysis to Remove Residual MR Gradient Artifact in the Simultaneous EEG/fMRI: A Preliminary Study

  • Conference paper
Neural Information Processing (ICONIP 2013)

Part of the book series: Lecture Notes in Computer Science ((LNTCS,volume 8228))

Included in the following conference series:

  • 4343 Accesses

Abstract

In the electroencephalography (EEG) data simultaneously acquired with the functional magnetic resonance imaging (fMRI) data, the removal of the residual magnetic resonance (MR) gradient artifacts has been a challenging issue. To remove gradient artifacts generated from switching MR gradient field, average artifact subtraction (AAS) has been widely used. After applying the AAS method, however, residual MR gradient artifacts still remained in corrected EEG data. In this study, we proposed a novel method to remove the residual MR gradient artifacts (GAs) using random segmentation based principal component analysis (rsPCA). The performance of rsPCA was compared to that of the independent component analysis (ICA) method using data acquired from a motor imagery task. The results indicated that rsPCA could suppress further the residual MR gradient artifacts remained from the AAS step compared to the ICA method.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Horwitz, B., Poeppel, D.: How Can EEG/MEG and fMRI/PET Data Be Combined? Hum. Brain. Mapp. 17, 1–3 (2002)

    Article  Google Scholar 

  2. Debener, S., Mullinger, K.J., Niazy, R.K., Bowtell, R.W.: Properties of the Ballistocardiogram Artefact as Revealed by EEG Recordings at 1.5, 3 and 7 T Static Magnetic Field Strength. Int. J. Psychophysiol. 67, 189–199 (2008)

    Article  Google Scholar 

  3. Allen, P.J., Polizzi, G., Krakow, K., Fish, D.R., Lemieux, L.: Identification of EEG Events in the MR Scanner: The Problem of Pulse Artifact and a Method for Its Subtraction. NeuroImage 8, 229–239 (1998)

    Article  Google Scholar 

  4. Allen, P.J., Josephs, O., Turner, R.: A Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI. NeuroImage 12, 230–239 (2000)

    Article  Google Scholar 

  5. Niazy, R.K., Beckmann, C.F., Iannetti, G.D., Brady, J.M., Smith, S.M.: Removal of FMRI environment artifacts from EEG data using optimal basis sets. NeuroImage 28, 720–737 (2005)

    Article  Google Scholar 

  6. Mantini, D., Perrucci, M.G., Cugini, S., Ferretti, A., Romani, G.L., Del Gratta, C.: Complete Artifact Removal for EEG Recorded during Continuous fMRI using Independent Component Analysis. NeuroImage 34, 598–607 (2007)

    Article  Google Scholar 

  7. Lee, J.H., Oh, S., Jolesz, F.A., Park, H.W., Yoo, S.S.: Application of Independent Component Analysis for the Data Mining of Simultaneous EEG-fMRI: Preliminary Experience on Sleep Onset. Int. J. Neurosci. 119, 1118–1136 (2009)

    Article  Google Scholar 

  8. Gonçalves, S.I., Pouwels, P.J.W., Kuijer, J.P.A., Heethaar, R.M., de Munck, J.C.: Artifact Removal in Co-registered EEG/fMRI by Selective Average Subtraction. Clin. Neurophysiol. 118, 2437–2450 (2007)

    Article  Google Scholar 

  9. Garreffa, G., Carnì, M., Gualniera, G., Ricci, G.B., Bozzao, L., De Carli, D., Morasso, P., Pantano, P., Colonnese, C., Roma, V., Maraviglia, B.: Real-Time MR Artifacts Filtering during Continuous EEG/fMRI Acquisition. Magn. Reson. Imaging 21, 1175–1189 (2003)

    Article  Google Scholar 

  10. Negishi, M., Abildgaard, M., Nixon, T., Constable, R.T.: Removal of Time-Varying Gradient Artifacts from EEG Data Acquired during Continuous fMRI. Clinical Neurophysiol. 115, 2181–2192 (2004)

    Article  Google Scholar 

  11. Liu, Z., de Zwart, J.A., van Gelderen, P., Kuo, L.W., Duyn, J.H.: Statistical Feature Extraction for Artifact Removal from Concurrent fMRI-EEG Recordings. NeuroImage 59, 2073–2087 (2012)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2013 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Kim, HC., Lee, JH. (2013). Random Segmentation Based Principal Component Analysis to Remove Residual MR Gradient Artifact in the Simultaneous EEG/fMRI: A Preliminary Study. In: Lee, M., Hirose, A., Hou, ZG., Kil, R.M. (eds) Neural Information Processing. ICONIP 2013. Lecture Notes in Computer Science, vol 8228. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-42051-1_14

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-42051-1_14

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-42050-4

  • Online ISBN: 978-3-642-42051-1

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics