Abstract
In the electroencephalography (EEG) data simultaneously acquired with the functional magnetic resonance imaging (fMRI) data, the removal of the residual magnetic resonance (MR) gradient artifacts has been a challenging issue. To remove gradient artifacts generated from switching MR gradient field, average artifact subtraction (AAS) has been widely used. After applying the AAS method, however, residual MR gradient artifacts still remained in corrected EEG data. In this study, we proposed a novel method to remove the residual MR gradient artifacts (GAs) using random segmentation based principal component analysis (rsPCA). The performance of rsPCA was compared to that of the independent component analysis (ICA) method using data acquired from a motor imagery task. The results indicated that rsPCA could suppress further the residual MR gradient artifacts remained from the AAS step compared to the ICA method.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Horwitz, B., Poeppel, D.: How Can EEG/MEG and fMRI/PET Data Be Combined? Hum. Brain. Mapp. 17, 1–3 (2002)
Debener, S., Mullinger, K.J., Niazy, R.K., Bowtell, R.W.: Properties of the Ballistocardiogram Artefact as Revealed by EEG Recordings at 1.5, 3 and 7 T Static Magnetic Field Strength. Int. J. Psychophysiol. 67, 189–199 (2008)
Allen, P.J., Polizzi, G., Krakow, K., Fish, D.R., Lemieux, L.: Identification of EEG Events in the MR Scanner: The Problem of Pulse Artifact and a Method for Its Subtraction. NeuroImage 8, 229–239 (1998)
Allen, P.J., Josephs, O., Turner, R.: A Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI. NeuroImage 12, 230–239 (2000)
Niazy, R.K., Beckmann, C.F., Iannetti, G.D., Brady, J.M., Smith, S.M.: Removal of FMRI environment artifacts from EEG data using optimal basis sets. NeuroImage 28, 720–737 (2005)
Mantini, D., Perrucci, M.G., Cugini, S., Ferretti, A., Romani, G.L., Del Gratta, C.: Complete Artifact Removal for EEG Recorded during Continuous fMRI using Independent Component Analysis. NeuroImage 34, 598–607 (2007)
Lee, J.H., Oh, S., Jolesz, F.A., Park, H.W., Yoo, S.S.: Application of Independent Component Analysis for the Data Mining of Simultaneous EEG-fMRI: Preliminary Experience on Sleep Onset. Int. J. Neurosci. 119, 1118–1136 (2009)
Gonçalves, S.I., Pouwels, P.J.W., Kuijer, J.P.A., Heethaar, R.M., de Munck, J.C.: Artifact Removal in Co-registered EEG/fMRI by Selective Average Subtraction. Clin. Neurophysiol. 118, 2437–2450 (2007)
Garreffa, G., Carnì, M., Gualniera, G., Ricci, G.B., Bozzao, L., De Carli, D., Morasso, P., Pantano, P., Colonnese, C., Roma, V., Maraviglia, B.: Real-Time MR Artifacts Filtering during Continuous EEG/fMRI Acquisition. Magn. Reson. Imaging 21, 1175–1189 (2003)
Negishi, M., Abildgaard, M., Nixon, T., Constable, R.T.: Removal of Time-Varying Gradient Artifacts from EEG Data Acquired during Continuous fMRI. Clinical Neurophysiol. 115, 2181–2192 (2004)
Liu, Z., de Zwart, J.A., van Gelderen, P., Kuo, L.W., Duyn, J.H.: Statistical Feature Extraction for Artifact Removal from Concurrent fMRI-EEG Recordings. NeuroImage 59, 2073–2087 (2012)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Kim, HC., Lee, JH. (2013). Random Segmentation Based Principal Component Analysis to Remove Residual MR Gradient Artifact in the Simultaneous EEG/fMRI: A Preliminary Study. In: Lee, M., Hirose, A., Hou, ZG., Kil, R.M. (eds) Neural Information Processing. ICONIP 2013. Lecture Notes in Computer Science, vol 8228. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-42051-1_14
Download citation
DOI: https://doi.org/10.1007/978-3-642-42051-1_14
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-42050-4
Online ISBN: 978-3-642-42051-1
eBook Packages: Computer ScienceComputer Science (R0)