Abstract

This paper proposes the use of vibrotactile feedback during telesurgery to notify surgeons of potential tissue puncture. Puncture trials using an experimental telesurgical apparatus were performed on an artificial membrane to characterize general force ranges at which punctures occur. The average force threshold during puncture was established, and human operators then attempted to apply a maximum force to the membrane without causing a puncture via the telesurgical apparatus. As the surgical tool-tip approached the pre-established force threshold, a wrist-mounted haptuator worn by the operators vibrated a warning. Warnings via different sensory modalities (auditory and tactile) were compared both with and without force feedback. Results show that the use of a warning via either sensory modality decreases the maximum force applied by the operator, thereby decreasing the occurrence of unintentional punctures. The inclusion of force feedback achieved similar results, though task completion times were significantly increased.

Keywords

  • haptics
  • haptuator
  • keyhole surgery
  • teleoperation
  • telesurgery
  • tissue puncture

This is a preview of subscription content, access via your institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • DOI: 10.1007/978-3-642-41068-0_4
  • Chapter length: 10 pages
  • Instant PDF download
  • Readable on all devices
  • Own it forever
  • Exclusive offer for individuals only
  • Tax calculation will be finalised during checkout
eBook
USD   39.99
Price excludes VAT (USA)
  • ISBN: 978-3-642-41068-0
  • Instant PDF download
  • Readable on all devices
  • Own it forever
  • Exclusive offer for individuals only
  • Tax calculation will be finalised during checkout
Softcover Book
USD   54.99
Price excludes VAT (USA)

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Varela, J.E., Wilson, S.E., Nguyen, N.T.: Laparoscopic surgery significantly reduces surgical-site infections compared with open surgery. Surg. End. 24(2), 270–276 (2010)

    CrossRef  Google Scholar 

  2. Reisch, R., Stadie, A., Kockro, R.A., Hopf, N.: The Keyhole Concept in Neurosurgery. World Neurosurgery (2012), http://www.sciencedirect.com/science/article/pii/S187887501200157X

  3. Meireles, O., Horgan, S.: Applications of surgical robotics in general surgery. In: Rosen, J., Hannaford, B., Satava, R.M. (eds.) Surgical Robotics: Systems Applications and Visions, pp. 791–812. Springer (2010)

    Google Scholar 

  4. Ahlering, T.E., Skarecky, D., Lee, D., Clayman, R.V.: Successful Transfer of Open Surgical Skills to a Laparoscopic Environment Using a Robotic Interface: Initial Experience With Laparoscopic Radical Prostatectomy. J. Urology. 170(5), 1738–1741 (2003)

    CrossRef  Google Scholar 

  5. Ballantyne, G.: Telerobotic Gastrointestinal Surgery: Phase 2Safety and Efficacy. Surg. End. 21(7), 1054–1062 (2007)

    CrossRef  Google Scholar 

  6. Carlsson, S., Nilsson, A.E., Schumacher, M.C., Jonsson, M.N., Volz, D.S., Steineck, G., Wiklund, P.N.: Surgery-related Complications in 1253 Robot-assisted and 485 Open Retropubic Radical Prostatectomies at the Karolinska University Hospital, Sweden. Urology. 75(5), 1092–1097 (2010)

    CrossRef  Google Scholar 

  7. Grantcharov, T.P., Kristiansen, V.B., Bendix, J., Bardram, L., Rosenberg, J., Funch-Jensen, P.: Randomized clinical trial of virtual reality simulation for laparoscopic skills training. Brit. J. Surg. 91(2), 146–150 (2004)

    CrossRef  Google Scholar 

  8. Xin, H., Zelek, J.S., Carnahan, H.: Laparoscopic surgery, perceptual limitations and force: A review. In: First Canadian Student Conference on Biomedical Computing, Kingston (2006)

    Google Scholar 

  9. Cuss, A., Abbott, J.: Complications of laparoscopic surgery. Obstetrics, Gynaecology and Reproductive Medicine 22(3), 59–62 (2012)

    CrossRef  Google Scholar 

  10. Lee, J.D., Hoffman, J.D., Hayes, E.: Collision warning design to mitigate driver distraction. In: SIGCHI Conference on Human Factors in Computing Systems, Vienna, pp. 65–72 (2004)

    Google Scholar 

  11. Spence, C., Ho, C.: Multisensory warning signals for event perception and safe driving. Theoretical Issues in Ergonomics Science 9(9), 523–554 (2008)

    CrossRef  Google Scholar 

  12. Okazaki, R., Kajimoto, H., Hayward, V.: Vibrotactile stimulation can affect auditory loudness: A pilot study. In: Isokoski, P., Springare, J. (eds.) EuroHaptics 2012, Part II. LNCS, vol. 7283, pp. 103–108. Springer, Heidelberg (2012)

    CrossRef  Google Scholar 

  13. Bark, K., McMahan, W., Remington, A., Gewirtz, J., Wedmid, A., Lee, D.I., Kuchenbecker, K.J.: In Vivo Validation of a System for Haptic Feedback of Tool Vibrations in Robotic Surgery. Surg. End., 1–9 (2012)

    Google Scholar 

  14. Bianchi, M., Gwilliam, J.C., Degirmenci, A., Okamura, A.M.: Characterization of an air jet haptic lump display. IEEE Eng. Med. Biol. Soc., 3467–3470 (2011)

    Google Scholar 

  15. Gwilliam, J.C., Pezzementi, Z., Jantho, E., Okamura, A.M., Hsiao, S.: Human vs. robotic tactile sensing: Detecting lumps in soft tissue. In: IEEE Haptics Symposium, Waltham, pp. 21–28 (2010)

    Google Scholar 

  16. Okamura, A.M., Webster III, R.J., Nolin, J.T., Johnson, K.W., Jafry, H.: The Haptic Scissors: Cutting in Virtual Environments. In: International Conference on Robotics and Automation, Taipei, pp. 828–833 (2003)

    Google Scholar 

  17. Park, J.W., Choi, J., Park, Y., Sun, K.: Haptic Virtual Fixture for Robotic Cardiac Catheter Navigation. Artificial Organs. 35(11), 1127–1131 (2011)

    CrossRef  Google Scholar 

  18. Gibo, T.L., Verner, L.N., Yuh, D.D., Okamura, A.M.: Design Considerations and Human-Machine Performance of Moving Virtual Fixtures. In: International Conference on Robotics and Automation, Kobe, pp. 671–676 (2009)

    Google Scholar 

  19. Yao, H.Y., Hayward, V.: Design and analysis of a recoil-type vibrotactile transducer. J. Acous. Soc. Am. 128(2), 619–627 (2010)

    CrossRef  Google Scholar 

  20. Lang, M.J., Greer, A.D., Sutherland, G.R.: Intra-operative Robotics: NeuroArm. In: Intraoperative Imaging Acta Neurochirurgica Supplementum, pp. 231–236. Springer-Verlag (2011)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and Permissions

Copyright information

© 2013 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

L’Orsa, R., Zareinia, K., Gan, L.S., Macnab, C., Sutherland, G. (2013). Potential Tissue Puncture Notification during Telesurgery. In: Oakley, I., Brewster, S. (eds) Haptic and Audio Interaction Design. HAID 2013. Lecture Notes in Computer Science, vol 7989. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-41068-0_4

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-41068-0_4

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-41067-3

  • Online ISBN: 978-3-642-41068-0

  • eBook Packages: Computer ScienceComputer Science (R0)