Abstract
One of the key problems in magnetic resonance (MR) image analysis is to remove the intensity inhomogeneity artifact present in MR images, which often degrades the performance of an automatic image analysis technique. In this regard, the paper presents a novel approach for bias field correction in MR images using the merit of contraharmonic mean, which is used in low-pass averaging filter to estimate the near optimum bias field in multiplicative model. A theoretical analysis is presented to justify the use of contraharmonic mean for bias field estimation. The performance of the proposed approach, along with a comparison with other bias field correction algorithms, is demonstrated on a set of MR images for different bias fields and noise levels.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Suetens, P.: Fundamentals of Medical Imaging. Cambridge University Press (2002)
Sled, J.G., Zijdenbos, A.P., Evans, A.C.: A Nonparametric Method for Automatic Correction of Intensity Nonuniformity in MRI Data. IEEE Transactions on Medical Imaging 17(1), 87–97 (1998)
Wells III, W.M., Grimson, W.E.L., Kikins, R., Jolezs, F.A.: Adaptive Segmentation of MRI Data. IEEE Transactions on Medical Imaging 15(8), 429–442 (1996)
Guillemaud, R., Brady, M.: Estimating the Bias Field of MR Images. IEEE Transactions on Medical Imaging 16(3), 238–251 (1997)
Pham, D.L., Prince, J.L.: Adaptive Fuzzy Segmentation of Magnetic Resonance Images. IEEE Transactions on Medical Imaging 18(9), 737–752 (1999)
Ahmed, M.N., Yamany, S.M., Mohamed, N., Farag, A.A., Moriarty, T.: A Modified Fuzzy C-Means Algorithm for Bias Field Estimation and Segmentation of MRI Data. IEEE Transactions on Medical Imaging 21(3), 193–199 (2002)
Ashburner, J., Friston, K.J.: Unified Segmentation. NeuroImage 26(3), 839–851 (2005)
Axel, L., Costantini, J., Listerud, J.: Intensity Correction in Surface-Coil MR Imaging. American Journal of Roentgenology 148, 418–420 (1987)
Zhou, L.Q., Zhu, Y.M., Bergot, C., Laval-Jeantet, A.M., Bousson, V., Laredo, J.D., Laval-Jeantet, M.: A Method of Radio-Frequency Inhomogeneity Correction for Brain Tissue Segmentation in MRI. Computerized Medical Imaging and Graphics 25(5), 379–389 (2001)
Narayana, P.A., Borthakur, A.: Effect of Radio Frequency Inhomogeneity Correction on the Reproducibility of Intra-Cranial Volumes Using MR Image Data. Magnetic Resonance in Medicine 33, 396–400 (1994)
Bedell, B.J., Narayana, P.A., Wolinsky, J.S.: A Dual Approach for Minimizing False Lesion Classifications on Magnetic-Resonance Images. Magnetic Resonance in Medicine 37(1), 94–102 (1997)
Brinkmann, B.H., Manduca, A., Robb, R.A.: Optimized Homomorphic Unsharp Masking for MR Grayscale Inhomogeneity Correction. IEEE Transactions on Medical Imaging 17(2), 161–171 (1998)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Banerjee, A., Maji, P. (2013). Contraharmonic Mean Based Bias Field Correction in MR Images. In: Wilson, R., Hancock, E., Bors, A., Smith, W. (eds) Computer Analysis of Images and Patterns. CAIP 2013. Lecture Notes in Computer Science, vol 8047. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-40261-6_63
Download citation
DOI: https://doi.org/10.1007/978-3-642-40261-6_63
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-40260-9
Online ISBN: 978-3-642-40261-6
eBook Packages: Computer ScienceComputer Science (R0)