Abstract
This paper gives a brief introduction on secondary pollution caused by central air-conditioning system of public buildings in cold region. Then, the feasibility analysis of humidity control of central air-conditioning system is conducted, which finds out that central air-conditioning system implementing humidity control can handle secondary pollution to some extent; but due to factors like the inadequate fresh air rate and restricted chilled water temperature, it cannot realize efficient control. The author proposes using activated carbon–nano-TiO2 photocatalytic composite purification technology to control secondary pollution caused by the system, and related tests are conducted. The results show that the compound purification unit can effectively purify VOCs and microbial pollution in sealed environment under certain conditions, and conditions including environmental temperature, ultraviolet intensity, air velocity, and initial pollutant concentration will influence the purifying performance.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Shen JM (1997) Indoor air quality evaluation. J HV AC 4(1):22–25
Li Y, Leung GM, Tang JW (2007) Role of ventilation in airborne transmission of infectious agents in the built environment—a multidisciplinary systematic review. Indoor Air 27(3):2–18
Li YF, Zhao YH, Chen P (2008) Preparation of the immobilized TiO2 activator and the experimental study on its photo activity. J Shenyang Jianzhu Univ Nat Sci 24(2):123–128
Daisey JM, Angell WJ, Apte MJ (2003) Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information. Indoor Air 2(13):53–64
Yu M (2007) Study on indoor pollution caused by central air conditioning and controlling. Master’s thesis, Shandong University, Shandong, China
Xu Q L (2007) The strategy to improve indoor air quality and eliminate secondly contamination of HVAC system. Master’s thesis, Tongji University, Shanghai, China
Yang XD, Xu FF (2006) Research and application of photocatalytic bactericidal effect in the air conditioning field. Build Energ Environ 5(1):11–16
Bluyssen PM, Oliverira FE, Groes L (1996) European audit project to optimize indoor air quality and energy consumption in office buildings. Indoor Air J 6(2):221–223
Acknowledgments
This research was supported by The Natural Science Foundation of Liaoning (20101088) and scientific and technical fund project subsidy of Shenyang City (F11-264-1-17 and F10-208-1-00).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Li, H., Geng, G., Feng, G., Wang, W., Guo, H. (2014). Experimental Research on Indoor Secondary Pollution and Control Technology of Public Buildings. In: Li, A., Zhu, Y., Li, Y. (eds) Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning. Lecture Notes in Electrical Engineering, vol 261. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-39584-0_24
Download citation
DOI: https://doi.org/10.1007/978-3-642-39584-0_24
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-39583-3
Online ISBN: 978-3-642-39584-0
eBook Packages: EngineeringEngineering (R0)