Abstract
The authors systematically summarized the research on the radiant cooling system in recent years. On the basis of a brief introduction of the radiant cooling system and its working principles, the advantages and disadvantages of the system were concluded compared with the conventional air conditioning system. The reasons for the slow development of radiant cooling system in China and its future trend were then discussed. It was suggested the solution to the condensation problem be focused on collecting and discharging the condensation water. This measure will not only improve the capacity of the radiant cooling system but also expand the application scope of the radiant cooling system.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Hu R, Niu J (2012) A review of the application of radiant cooling & heating systems in Mainland China. Energy Build 52:11–19
Wang Z (2004) Radiant heating and raiant cooling. Chian Machine Press, Beijing
Han G, Qu X (2011) An analysis of radiant cooling with displacement ventilation composite system. ChengShi Jianshe LiLun Yan Jiu 22
Chen L, Liao S (2010) Three approaches to the comparative study of indoor thermal environment for radiant cooling system. Build Energy Environ 29(3):53–56
Lu S, Zhang S (2011) Theory study on condensation problem of floor radiant cooling system. J Jiangsu Univ Sci Technol (Nat Sci Ed) 25(6):565–571
Shi Y, Chen Y et al (2011) Air quality of radiant cooling combined with wall-attached-jet system. HV&AC 41(2):60–63
Zhou G, Shi Y et al (2011) Studies of anti-condensation of the radiant cooling system with wall-attached-jet. Build Energy Environ 30(5):20–22
Xiao Y, Fu X (2002) Dehumidifying capability of outdoor air in cooling ceiling system application. HV&AC 32(3):15–17
Xia X, Zhang X et al (2008) Technology analysis and experimental research on radiant floor cooling combined with dedicated outdoor air system. J Refrig 29(4):18–23
He J, Shen J et al (2008) Discussion on condensation of radiant cooling system combined with DOAS. HV&AC 38(6):159–162
Zhang B, Song L, Wang J (2009) Experimental study on cooling ceiling air-conditioning system covered and airproofed with the film whose long wave transmittance (LWT) is high. CC&AC 3:23–26
Kong X, Zhang X, Lu S (2008) Research status of condensation of radiant cooling and its countermeasures. Build Energy Environ 27(1):20–23
Kong X, Zhang D, Zhang X (2011) Design and analysis of leading condensation radiant panel. J Jiangsu Univ Sci Technol (Nat Sci Ed) 25(5):440–446
Liu J, Wu Z et al (2010) Radiant ceiling system design and research for EXPO Hamburg Haus. Refrig Air-conditioning 10(3):94–97
Fan L, He K, Wan S (2005) Study and application of floor panel heating/cooling system in lobbies of Wukesong Gymnasium. HV&AV 35(6):87–90
Zou Z, Li G, Zhu J (2010) Design of air conditioning system for tianjin railway station. HV&AC 40(5):32–35
Lu S, Lv Y et al (2010) Numerical simulation and experiment research for radiant cooling-displacement ventilation system. Build Energy Environ 29(2):25–29
Xuan Y, Wang H, Huang X (2012) Simulation analysis of radiation floor with displacement ventilation air conditioning system by energyplus. Fluid Mach 40(8):65–68
Yan Z (2010) Discussion on combined air- conditioning system based on radiant heating and cooling with evaporative cooling. Refrigeration 114:18–23
Gao Z, Liu X, Jiang Y (2011) Experiment study on cooling capacity of capillary-tube radiation air-conditioner. Acta Energiae Solaris Sinica 32(2):101–106
Gao Z, Liu X et al (2011) Influence factors and calculation method of radiant panel cooling capacity. HV&AC 41(1):33–37
Zhang L, Liu X et al (2012) Simplified calculation method for the cooling capacity and surface temperature distribution of floor panel. HV&AV 42(5):41–46
Fong KF, Chow TT et al (2011) Solar hybrid cooling system for high-tech offices in subtropical climate—Radiant cooling by absorption refrigeration and desiccant dehumidification. Energy Convers Manage 52:2883–2894
De Carli M, Massimo T (2011) Effect of modelling solar radiation on the cooling performance of radiant floors. ScienceDirect 85:689–712
Doosam S, Taeyeon K et al (2008) Performance evaluation of a radiant floor cooling system integrated with dehumidified ventilation. ScienceDirect 28:1299–1311
Corina S (1999) Energy and peak power savings potential of radiant cooling systems in US commercial buildings. Energy Build 30:127–138
Suya W, Megumi M (2008) Evaluating the low exergy of chilled water in a radiant cooling system. Energy Build 40:1856–1865
Prapapong V, Surapong C (2007) Application of radiant cooling as a passive cooling option in hot humid climate. ScienceDirect 42:543–556
Simos O, Agis MP (2013) Performance of radiant cooling surfaces with respect to energy consumption and thermal comfort. Energy Build 57:199–209
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Wang, H., Shu, H., Duanmu, L. (2014). A Review on Radiant Cooling System in Buildings of China. In: Li, A., Zhu, Y., Li, Y. (eds) Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning. Lecture Notes in Electrical Engineering, vol 262. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-39581-9_11
Download citation
DOI: https://doi.org/10.1007/978-3-642-39581-9_11
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-39580-2
Online ISBN: 978-3-642-39581-9
eBook Packages: EngineeringEngineering (R0)