Abstract
In order to improve the stability of bio-diesel fuel, the system which is combination of ultrasonic and bio-diesel fuel use ultrasonic as the additional energy, and investigate the Ultrasonic frequency, waveforms, power and ultrasonic time factors and the effects of bio-diesel fuel stability. Optimal operating parameters of ultrasonic generator were studied by orthogonal experiment. The ultrasonic generator could adjust frequency, power, waveform and treating time flexibly in order to compare the stability of bio-diesel fuel under different conditions. According to the results, treating time had the most significant in fluency on the stability, power and frequencies were less important than it and waveform was the least.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Fang, H.: The influence of ultrasonic wave on diesel emulsion. Petroleum Chemical Industry (8), 615–618 (2001)
Rozenberg, L.D.: High-Intensity Ultrasonic Fields. Plenum Predd, New York (1971)
Dai, Y.: Under the effect of Ultrasonic Deep Desulfurization of high sulfur fuel, Harbin Institute of Technology, pp. 17–22 (2009)
Zhao, Y.Y., Feng, R., Yun, Y.X.: Frequency to the sound of the formation of the influence of hydroxyl radicals. Acoustic Technology 17(1), 12–14 (1998)
De-Ping, F., Chen, S.L.: Vibration waveform interference effects on dendritic growth. Journal of Synthetic Crystals 15(4), 35–39 (1989)
Xue, Y.W., Ji, M.: Ultrasonic power of the ultrasonic cracked. The influence of sludge. Journal of Chemical Engineering 58(4), 1037–1039 (2007)
Wang, L., Wang, S.: Influence of emulsification bio fuel stability of experimental study. Eight One Farming Cultivate University Journal 10(5), 26–29 (2010)
Jiang, J., Yang, S.: Groove type ultrasonic generator for improving sludge dewatering performance. Application of Basic Science and Engineering 12(6), 852–859 (2009)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Wei, Xl., Wang, Sy., Wang, Z. (2012). The Research of Ultrasound Parameters Affecting the Stability of Bio-diesel Fuel for Mechanical Engineering. In: Jin, D., Lin, S. (eds) Advances in Mechanical and Electronic Engineering. Lecture Notes in Electrical Engineering, vol 176. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-31507-7_45
Download citation
DOI: https://doi.org/10.1007/978-3-642-31507-7_45
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-31506-0
Online ISBN: 978-3-642-31507-7
eBook Packages: EngineeringEngineering (R0)