Adaptive Windowing for Optimal Visualization of Medical Images Based on a Structural Fidelity Measure

  • Hojatollah Yeganeh
  • Zhou Wang
  • Edward R. Vrscay
Part of the Lecture Notes in Computer Science book series (LNCS, volume 7325)

Abstract

Medical imaging devices often capture the raw data with high precision, producing high dynamic range (HDR) images. To visualize HDR images on regular displays, there has been an increasing number of tone mapping algorithms developed in recent years that convert HDR to low dynamic range (LDR) images. To visualize HDR medical images, a so-called “windowing” procedure is typically employed by which the structural details within the intensity region of interest is mapped to the dynamic range of regular displays. Linear mapping is the most straightforward windowing operator, but may not be the optimal mapping function in terms of structure preserving. Here we propose a framework to adaptively find the optimal windowing function for different images. Specifically, a recently developed structural fidelity measure for tone mapped images is employed to adaptively optimize the windowing function, so as to achieve the best structural fidelity with respect to the original HDR image. Experiments demonstrate the promising performance of the proposed adaptive windowing method.

Keywords

Window Width High Dynamic Range Optimal Visualization Window Center Adaptive Window 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Barten, P.G.J.: Contrast sensitivity of the human eye and its effects on image quality. SPIE Optical Engineering Press, Washington (1999)CrossRefGoogle Scholar
  2. 2.
    Cavaro-Menard, C., Zhang, L., Le Callet, P.: Diagnostic quality assessment of medical images: Challenges and trends. In: 2010 2nd European Workshop on Visual Information Processing, EUVIP 2010, pp. 277–284 (2010)Google Scholar
  3. 3.
    Cosman, P.C., Gray, R.M., Olshen, R.A.: Evaluating quality of compressed medical images: SNR, subjective rating, and diagnostic accuracy. Proceedings of the IEEE 82(6), 919–932 (1994)CrossRefGoogle Scholar
  4. 4.
    Koff, D., Bak, P., Brownrigg, P., Hosseinzadeh, D., Khademi, A., Kiss, A., Lepanto, L., Michalak, T., Shulman, H., Volkening, A.: Pan-canadian evaluation of irreversible compression ratios (“lossy” compression) for development of national guidelines. Journal of Digital Imaging 22(6), 569–578 (2009)CrossRefGoogle Scholar
  5. 5.
    Reinhard, E., Ward, G., Pattanaik, S., Debevec, P., Heidrich, W., Myszkowski, K.: High Dynamic Range Imaging: Acquisition, Display, and Image-Based Lighting. Morgan Kaufmann Publishers Inc. (2010)Google Scholar
  6. 6.
    Wang, Z., Bovik, A.C., Sheikh, H.R., Simoncelli, E.P.: Image quality assessment: From error visibility to structural similarity. IEEE Trans. Image Proc. 13, 35–44 (2004)Google Scholar
  7. 7.
    Yeganeh, H., Wang, Z.: Objective assessment of tone mapping algorithms. In: Proc. IEEE Int. Conf. Image Proc. (September 2010)Google Scholar
  8. 8.
    Yeganeh, H., Wang, Z.: Objective quality assessment of tone mapped images. Submitted to IEEE Trans. Image Proc. (2011)Google Scholar
  9. 9.
    Yeganeh, H., Wang, Z.: Structural Fidelity vs. Naturalness - Objective Assessment of Tone Mapped Images. In: Kamel, M., Campilho, A. (eds.) ICIAR 2011, Part I. LNCS (LNAI, LNBI), vol. 6753, pp. 111–121. Springer, Heidelberg (2011)CrossRefGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2012

Authors and Affiliations

  • Hojatollah Yeganeh
    • 1
  • Zhou Wang
    • 1
  • Edward R. Vrscay
    • 2
  1. 1.Department of Electrical and Computer Engineering, Faculty of EngineeringUniversity of WaterlooWaterlooCanada
  2. 2.Department of Applied Mathematics, Faculty of MathematicsUniversity of WaterlooWaterlooCanada

Personalised recommendations