Abstract
Digital x-ray acquisition allows the sophisticated processing of acquired images before display to the reader, making possible such operations as the removal in software of the systematic blurring effect of scatter. A method for analysing scatter removal is presented. The scatter model incorporated within the Standard Attenuation Rate (SAR) is used, which is a method for calculating a normalised image of tissue radiodensity. The model builds on the fundamental physical relations underlying Monte Carlo techniques; but through optimal information sampling and interpolation is able to execute in a clinically realistic time. The scatter kernel arising around each primary ray is calculated, and these are superimposed to give the scatter image. An iterative refinement procedure is used to calculate the radiodensity and scatter at each ray/pixel, cyclically feeding back to each other, to yield the scatter field. Image sharpness and contrast-to-noise (CNR) analysis is presented for two tissue equivalent phantoms. The algorithm is found to be able to match image sharpness without the grid, to that with the grid present, confirmed by residual analysis using autocorrelation plots which show the difference is almost white noise within a 95% C.I. The increased fluence in the absence of the grid is shown to allow dose to be reduced by 37-49%, whilst delivering equivalent contrast and CNR.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Tromans, C.: DPhil Thesis: Measuring Breast Density from X-Ray Mammograms. DPhil Thesis, Engineering Science. Oxford University (October 2006)
Tromans, C.E., Brady, S.M.: The Standard Attenuation Rate for Quantitative Mammography. In: Martí, J., Oliver, A., Freixenet, J., Martí, R. (eds.) IWDM 2010. LNCS, vol. 6136, pp. 561–568. Springer, Heidelberg (2010)
Young, K.C., et al.: Optimal beam quality selection in digital mammography. Br. J. Radiol. 79, 981–990 (2006)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Tromans, C., Cocker, M., Brady, S.M. (2012). Digital Scatter Removal for Mammography and Tomosynthesis Image Acquisition. In: Maidment, A.D.A., Bakic, P.R., Gavenonis, S. (eds) Breast Imaging. IWDM 2012. Lecture Notes in Computer Science, vol 7361. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-31271-7_34
Download citation
DOI: https://doi.org/10.1007/978-3-642-31271-7_34
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-31270-0
Online ISBN: 978-3-642-31271-7
eBook Packages: Computer ScienceComputer Science (R0)