Abstract
We developed the first non-commercial treatment planning system for volumetric modulated radiation therapy (VMAT) in the United States. Because VMAT involves multiparameter modulations, it is imperative to develop a comprehensive, rigorous and yet, practical procedure for routine patient-specific quality assurance (QA). In this paper, we present our own approach as being currently implemented in our institution. Our patient-specific QA procedure involves multi-levels: pre-treatment QA, on-treatment QA, and posttreatment QA. The pre-treatment QA focuses on dosimetry verification. It is done with the commercial MapCHECK in MapPHAN mounted on an isocentric mounting fixture (IMF). This method is also referred to as the fixed-gantry technique, i.e., the beams always remain perpendicular to the detector plane. The on-treatment QA involves in-vivo optically stimulated luminescent dosimetry (OSLD). Prior to the treatment, two nanoDot TM OSLD dosimeters are placed on the patient abdomen under 1 cm bolus at the isocenter location. The irradiated dosimeters are then read by a nanoDotTM reader and the average reading of the two is calculated. The post-treatment QA involves the analysis of the DynaLog and DLog files. The DynaLog is a treatment log file that contains the planned and actual leaf positions at a given gantry angle. The DLog is a treatment log file that contains the planned segmented treatment table (STT) and the corresponding segment boundary samples, i.e., the actual delivered MU and gantry angle increment at each control point.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Song, Y., Obcemea, C., Mueller, B., Mychalczak, B. (2013). A Systematic Approach to Patient Specific QA For Volumetric Modulated Arc Therapy (VMAT). In: Long, M. (eds) World Congress on Medical Physics and Biomedical Engineering May 26-31, 2012, Beijing, China. IFMBE Proceedings, vol 39. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-29305-4_493
Download citation
DOI: https://doi.org/10.1007/978-3-642-29305-4_493
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-29304-7
Online ISBN: 978-3-642-29305-4
eBook Packages: EngineeringEngineering (R0)