Skip to main content

A Systematic Approach to Patient Specific QA For Volumetric Modulated Arc Therapy (VMAT)

  • Conference paper
World Congress on Medical Physics and Biomedical Engineering May 26-31, 2012, Beijing, China

Part of the book series: IFMBE Proceedings ((IFMBE,volume 39))

Abstract

We developed the first non-commercial treatment planning system for volumetric modulated radiation therapy (VMAT) in the United States. Because VMAT involves multiparameter modulations, it is imperative to develop a comprehensive, rigorous and yet, practical procedure for routine patient-specific quality assurance (QA). In this paper, we present our own approach as being currently implemented in our institution. Our patient-specific QA procedure involves multi-levels: pre-treatment QA, on-treatment QA, and posttreatment QA. The pre-treatment QA focuses on dosimetry verification. It is done with the commercial MapCHECK in MapPHAN mounted on an isocentric mounting fixture (IMF). This method is also referred to as the fixed-gantry technique, i.e., the beams always remain perpendicular to the detector plane. The on-treatment QA involves in-vivo optically stimulated luminescent dosimetry (OSLD). Prior to the treatment, two nanoDot TM OSLD dosimeters are placed on the patient abdomen under 1 cm bolus at the isocenter location. The irradiated dosimeters are then read by a nanoDotTM reader and the average reading of the two is calculated. The post-treatment QA involves the analysis of the DynaLog and DLog files. The DynaLog is a treatment log file that contains the planned and actual leaf positions at a given gantry angle. The DLog is a treatment log file that contains the planned segmented treatment table (STT) and the corresponding segment boundary samples, i.e., the actual delivered MU and gantry angle increment at each control point.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yulin Song .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2013 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Song, Y., Obcemea, C., Mueller, B., Mychalczak, B. (2013). A Systematic Approach to Patient Specific QA For Volumetric Modulated Arc Therapy (VMAT). In: Long, M. (eds) World Congress on Medical Physics and Biomedical Engineering May 26-31, 2012, Beijing, China. IFMBE Proceedings, vol 39. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-29305-4_493

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-29305-4_493

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-29304-7

  • Online ISBN: 978-3-642-29305-4

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics