Abstract
In the near infrared spectral region, a reflection plant water detection instrument was designed by using microcontroller STC12C5A60S2. The instrument consisted of signal acquisition system, microcontroller system, software system and calibration model. The signal acquisition system was composed of three LED of different wavelength and a light-to-frequency converter. Three LED of different wavelength were lighted by turns for avoiding interaction. Light-to-frequency converter was used as the receiving tube, thus simplifying the circuit structure greatly. This paper described the instrument’s hardware design, software design, modeling of Forsythia leaf water content and forecasting. Predicted results were consistent with the true values of water, and the correlation coefficient between them was about 0.820. Advantages of this instrument were small, simple structure, low power consumption and so on. The experimental results showed that the instrument could detect plant water content rapidly on fieldwork.
Chapter PDF
Similar content being viewed by others
References
Zhang, J., Duan, A., Sun, J.: Advances in Automated Monitoring and Diagnosis of Crop Water Status (in Chinese). Transactions of the Chinese Society of Agricultural Engineering 22(1), 174–178 (2006)
Tian, Y., Zhu, Y., Cao, W.: Relationship between Canopy Reflectance and Plant Water Status of Wheat (in Chinese). Chinese Journal of Applied Ecology 15(11), 2072–2076 (2004)
Hunt Jr., E.R., Barrett, N.R.: Detection of Changes in Leaf Water Content Using Near-and Middle-Infrared Reflectance. Remote Sensing of Environment 30, 43–54 (1989)
Wang, J., Zhao, C., Guo, X.: Study on the Water Status of the Wheat Leaves Diagnosed by the Spectral Reflectance (in Chinese). Scientia Agricultura Sinica 34(1), 104–107 (2001)
Liu, L., Wang, J., Huang, W.: Estimating Winter Wheat Plant Water Content Using Red Edge Parameters (in Chinese). International Journal of Remote Sensing 25(17), 3331–3342 (2004)
Rollin, M.E., Milton, E.J.: Processing of High Spectral Resolution Reflectance Data for the Retrieval of Canopy Water Information. Remote Sensing of Environment 65, 86–92 (1998)
Tucker, C.J.: Remote Sensing of Leaf Water Content in the Near Infrared. Remote Sense Environ. 10, 23–32 (1980)
Carter, G.A., Paliwal, K., Pathre, U., Green, T.H., Mitchell, R.J., Gjerstad, D.H.: Effect of Competition and Leaf Age on Visible and Infrared Reflectance in Pine Foliage. Plant Cell Environ. 12, 309–315 (1989)
Hunt Jr., E.R., Rock, B.N., Nobel, P.S.: Measurement of Leaf Relative Water Content by Infrared Reflectance. Remote Sense Environ. 22, 429–435 (1987)
Hunt Jr., E.R., Rock, B.N.: Detection of Changes in Leaf Water Content Using Near and Middle Infrared Reflectance. Remote Sense Environ. (1990)
Penuelas, J., Filella, I., Biel, C.: The Reflectance at the 950-970nm Region as an Indicator of Plant Water Status. International Journal of Remote Sense 14, 1887–1905 (1993)
Penuelas, J., Inoue, Y.: Reflectance Indices Indicative of Changes in Water and Pigment Contents of Peanut and Wheat Leaves. Photosynthetica 36(3), 355–360 (1999)
Penuelas, J., Pinol, J., Ogaya, R.: Estimation of Plant Water Concentration by the Reflectance Water Index WI (R900/R970). International Journal of Remote Sense 18, 2869–2872 (1997)
Shen, Y., Niu, Z., Wang, W.: Establishment of Leaf Water Content Models Based on Derivative Spectrum Variables (in Chinese). Geography and Geo-Information Science 21(4), 16–19 (2005)
Mao, H., Zhang, X., Li, X.: Model Establishment for Grape Leaves Dry-Basis Moisture Content Based on Spectral Signature (in Chinese). Journal of Jiangsu University 29(5), 369–372 (2008)
Yang, Y., Zhang, D., Li, S., Hu, C.: Model for Citrus Leaves Water Content Based on Spectral Signature (in Chinese). Chinese Agricultural Science Bulletin 27(2), 180–184 (2011)
Li, J., Zhao, L., Lao, C.: Modern Near Infrared Spectral Analysis Technology of Farm Products (in Chinese). Modern Scientific Instruments 1, 17–19 (2005)
Yuan, H., Long, Y., Lu, W.: A New Infrared Spectrometer with Charge Coupled Device Detector (in Chinese). Chinese Journal of Analytical Chemistry 27(5), 608–614 (1999)
Zhou, X., Zhu, Y., Liu, X.: Instrument Technology and Applications of Modern Fourier Transform Near Infrared Spectrometer (in Chinese). Modern Instruments 8(4), 29–32 (2002)
Lin, X.: Develop on Near Infrared Moisture Instrument (in Chinese). China Instrumentation 2, 13–14 (2001)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 IFIP International Federation for Information Processing
About this paper
Cite this paper
Jia, J., Ji, H. (2012). Plant Leaf Water Detection Instrument Based on Near Infrared Spectroscopy. In: Li, D., Chen, Y. (eds) Computer and Computing Technologies in Agriculture V. CCTA 2011. IFIP Advances in Information and Communication Technology, vol 370. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-27275-2_3
Download citation
DOI: https://doi.org/10.1007/978-3-642-27275-2_3
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-27274-5
Online ISBN: 978-3-642-27275-2
eBook Packages: Computer ScienceComputer Science (R0)