Abstract
Establishing a process chain for designing topology-optimized implants requires the inclusion of discipline-specific design paths that may vary significantly when considered from a medical or an engineering point of view. Creating a joint design platform is viewed as an innovative approach. The objectives include efficient communication and transfer of results between engineers and medical professionals based on software-implemented interfaces. These include aspects of modeling for design, translation to the medical environment and the surgeon’s planning of the surgical procedure. Selected partial aspects of the developed design engineering process chain are presented based on project examples from the fields of vascular surgery and hip arthroplasty.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Höfele F (ed) (2009) Qualität sichtbar machen: BQS-Qualitätsreport 2008. Bundesgeschäftsstelle Qualitätssicherung
Bensmann G, Piotrowski A (2004) Zementfreie Hüftpfannen – Welcher Werkstoff ist für welches Design geeignet? In: Effenberger H; Aldinger GH (eds) Pressfitpfannen. Grundlagen, Konzepte, Ergebnisse, Qualitätssicherung. MCU, Grieskirchen, pp 3–8
Wintermantel E, Shah-Derler B, Bruinink A, Petitmermet M, Blum J, Ha S (2007) Biokompatibilität. In: Wintermantel E; Ha S (eds) Medizintechnik. Life Science Engineering, 4th edn. Springer Verlag Berlin Heidelberg, Heidelberg, pp 59–96
Witzel R, Rieger W, Effenberger H (2004) 3D-Finite-Elemente-Analyse zementfreier Hüftpfannen. In: Effenberger H; Aldinger GH (eds) Pressfitpfannen. Grundlagen, Konzepte, Ergebnisse, Qualitätssicherung. MCU, Grieskirchen, pp 73–78
Behrens B, Bouguecha A, Nolte I, Meyer-Lindenberg A, Stukenborg-Colsman C, Pressel T (2008) Strain adaptive bone remodelling: influence of the implantation technique. Stud Health Technol Inform 133:33–44
Liang DK, Yang DZ, Qi M, Wang WQ (2005) Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery. Int. J. Cardiol 104(3):314–318. doi: 10.1016/j.ijcard.2004.12.033
Migliavacca F, Petrini L, Massarotti P, Schievano S, Auricchio F, Dubini G (2004) Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall. Biomech Model Mechanobiol 2(4):205–217. doi: 10.1007/s10237-004-0039-6
Thomas W, Lucente L, Mantegna N, Grundei H (2004) Die ESKA Kapuzinerpfanne – Ein bionisches Konzept zur Verwirklichung einer Pressfit-Fixation. In: Effenberger H; Aldinger GH (eds) Pressfitpfannen. Grundlagen, Konzepte, Ergebnisse, Qualitätssicherung. MCU, Grieskirchen, pp 113–118
Wu W, Wang W, Yang D, Qi M (2007) Stent expansion in curved vessel and their interactions: A finite element analysis. Journal of Biomechanics 40(11):2580–2585. doi: 10.1016/j.jbiomech.2006.11.009
Kozic N, Weber S, Büchler P, Lutz C, Reimers N, González Ballester MA, Reyes M (2010) Optimisation of orthopaedic implant design using statistical shape space analysis based on level sets. Med Image Anal 14(3):265–275. doi: 10.1016/j.media.2010.02.008
Deutsches Institut für Normung e. V. (1998) Aktive implantierbare medizinische Geräte – Teil 1: Allgemeine Festlegungen für die Sicherheit, Aufschriften und vom Hersteller zur Verfügung zu stellende Informationen. Beuth Verlag GmbH, Berlin(DIN EN 45502-1)
Deutsches Institut für Normung e. V. (2009) Nichtaktive chirurgische Implantate – Allgemeine Anforderungen. Beuth Verlag GmbH, Berlin(DIN EN ISO14630)
Deutsches Institut für Normung e. V. (2009) Nichtaktive chirurgische Implantate – Implantate zum Gelenkersatz – Besondere Anforderungen. Beuth Verlag GmbH, Berlin(DIN EN ISO 215340)
Martin A, von Strempel A, Kistmacher H (2004) FGL-Konzepte – Wachsende Pressfitpfannen mit Form-Gedächtnis-Legierung. In: Effenberger H; Aldinger GH (eds) Pressfitpfannen. Grundlagen, Konzepte, Ergebnisse, Qualitätssicherung. MCU, Grieskirchen, pp 123–125
Schaller A, Voigt C, Mai J, Quickert M, Klöhn C, Scholz R (2010) FEM-Analyse zum Einfluss von Knochendefekten auf die Implantatverankerung in der Hüftrevisionsendoprothetik. In: Deutscher Kongress für Orthopädie und Unfallchirurgie. 74. Jahrestagung der Deutschen Gesellschaft für Unfallchirurgie, 96. Tagung der Deutschen Gesellschaft für Orthopädie und Orthopädische Chirurgie, 51. Tagung des Berufsverbandes der Fachärzte für Orthopädie. Berufsverbandes der Fachärzte für Orthopädie. German Medical Science GMS Publishing House, Düsseldorf
Wirtz T P (2005) Herstellung von Knochenimplantaten aus Titanwerkstoffen durch Laserformen. Dissertation, RWTH Aachen, Aachen
Janssens M, Poukens J (2007) Rapid Technologies in medicine: What can, can’t be done and why. In: International Conference on Competitive Manufacturing. COMA; Stellenbosch, South Africa, January 31 – February 2
Müller B (2009). Generative Fertigungsverfahren – Möglichkeiten der Herstellung patientenspezifischer Implantate und medizintechnischer Komponenten. Workshop Präzisionsfertigung für die Medizintechnik; Chemnitz, Germany, May 13,. proceedings.
Töppel T, Gebauer M, Müller B, Neugebauer R, (2011) Neue Funktionen in Endoprothesen durch generative Fertigung mit Strahlschmelzen. In: Proceedings of Rapid.Tech 2011 trade fair and user’s conference for rapid technology. Rapid.Tech, Erfurt, Germany, May 24–25. Messe Erfurt, Erfurt, p 80
Maßberg W, Machtens E, Heuser L, Wehmöller M (1999) Disziplinübergreifende Prozeßkette vom CT bzw. MR zum Implantat. In: Maßberg W (ed) 1. Symposium: Neue Technologien für die Medizin, Forschung – Praxis – Innovation. Utz, München, pp 106–118
Van den Heever D, Mueller C, Scheffer C (2011) Patientenspezifisches Design von Knie-Implataten. Computer Aided Medical Engineering caMe 2(1):22–23
Entacher K, Petutschnigg A, Pomwenger W, Resch H, Schuller-Götzburg P (2010) Patientenspezifische Optimierung von Schulterimplantaten. Computer Aided Medical Engineering caMe 1(1):12–17
Ollenschläger G, Bucher H, Donner-Banzhoff N, Forster J, Gaebel W, Kunz R, Müller OA, Neugebauer E, Steurer J (ed) (2006) Kompendium evidenzbasierte Medizin. 5.Auflage, Huber Hans, ISBN 978-3456843308
Helgason B, Perilli E, Schileo E, Taddei F, Brynjólfsson S, Viceconti M (2008) Mathematical relationships between bone density and mechanical properties: a literature review. Clinical biomechanics (Bristol, Avon) 23(2):135–146. doi: 10.1016/j.clinbiomech.2007.08.024
Ewins DJ (2000) Modal testing: Theory, practice, and application, 2nd edn. Research Studies Press, Baldock, Hertfordshire, England;, Philadelphia, PA
Tillmann B.N. (2010) Atlas der Anatomie des Menschen. Springer Verlag Berlin Heidelberg, Berlin, Heidelberg
Rotsch C, Werner M, Drossel W (2010) Einsatz eines 3D-Lasermesssystems zur Bestimmung modaler Parameter humaner Hüftbeine. In: Füssel J, Koch E, Malberg H (ed) 3. Dresdner Medizintechnik-Symposium. mit DFG Forschungsschwerpunkt Protektive Beatmungskonzepte, Dresden, 6.-9. Dezember 2010. Verlag der Wissenschaften GmbH, Dresden, pp 43–48
Neugebauer R, Werner M, Voigt C, Steinke H, Scholz R, Scherer S, Quickert M (2011) Experimental modal analysis on fresh-frozen human hemipelvic bones employing a 3D laser vibrometer for the purpose of modal parameter identification. Journal of Biomechanics. doi: 10.1016/j.jbiomech.2011.03.005
Scherer S, Treichel T, Ritter N, Triebel G, Drossel WG, Burgert O (2010) Surgical stent planning: simulation parameter study for models based on DICOM standards. Int J CARS. doi: 10.1007/s11548-010-0511-y
Fung YC, Fronek K, Patitucci P (1979) Pseudoelasticity of arteries and the choice of its mathematical expression. American Physiological Society, pp. 620–631
Holzapfel G, Sommer G, Regitnig P (2004) Anisotropic Mechanical Properties of Tissue Components in Human Atherosclerotic Plaques. Journal of Biomechanical Engineering(Vol. 126). doi: 10.1115/1.1800557
Prendergast PJ, Lally C, Daly S, Reid AJ, Lee TC, Quinn D, Dolan F (2003) Analysis of prolapse in cardiovascular stents: a constitutive equation for vascular tissue and finite-element modelling. J Biomech Eng 125(5):692–699
Holzapfel G (2002) Biomechanics of Soft Tissues with Application to Arterial Walls. Mathematical and Computational Modeling of Biological – Chapter 1, Centro Internacional de Matemática CIM:1–37
Gebert de Uhlenbrock A (2009) Desinganalyse von endovaskulären Aortenprothesen. Dissertation, Technische Universität Hamburg-Harburg, Hamburg
Choplin RH, Boehme JM, Maynard CD (1992) Picture archiving and communication systems: an overview. Radiographics 12(1):127–129
Pianykh OS (2008) Digital imaging and communications in medicine (DICOM): A practical introduction and survival guide. Springer, Berlin
Ritter N, Werner M, Scherer S, Drossel WG, Burgert O (2010) Repräsentation flexibler Implantate durch DICOM. In: Chirurgische Interventionen. Vom Neandertaler zur Roboterassistenz; 9. Jahrestagung der Deutschen Gesellschaft für Computer- und Roboterassistierte Chirurgie (CURAC), 18. bis 19. November 2010, Düsseldorf; proceedings. Der Andere Verl, Tönning, pp 53–56
Scherer S, Treichel RT, Drossel WG, Burgert O (2010) Physically-based Models for Virtual Stent Planning and Simulation Based on Open Standards. In: Proceedings of the 24th International Congress and Exhibition. CARS, Geneva, Switzerland, June 23–26. Springer Heidelberg, Heidelberg, p 273
National Electrical Manufacturers Association (2008) Implant Templates (Digital Imaging and Communications in Medicine DICOM 131)
National Electrical Manufacturers Association Implantation Plan SR Document (Digital Imaging and Communications in Medicine DICOM 134)
Heller K (2005) Indikationen bei modularen Implantaten. In: Thümler P FRZG (ed) Modulare Revisionsendoprothetik des Hüftgelenks. Springer Medizin Verlag Heidelberg, pp 124–132
Holzwarth U, Schuh A, Zeiler G (2005) Biomechanische Aspekte der Revisionsendoprothtik. In: Thümler P FRZG (ed) Modulare Revisionsendoprothetik des Hüftgelenks. Springer Medizin Verlag Heidelberg, pp 60–75
Bouguecha A (2007) Numerische und experimentelle Untersuchungen zum beanspruchungsadaptiven Knochenumbau im periprothetischen caninen Femur. Wissenschaftliche Schriftenreihe. PZH Produktionstechnisches Zentrum GmbH, Garbsen
Böhm A, Kunze H (2007) Aktive Werkstoffe mit Gedächtnis – Neue Aktorkonzepte basierend auf dem Formgedächtniseffekt. Beitrag zum Dresdner Transferbrief, Innovative Werkstoffe
Drossel W, Neugebauer R, Kranz B (2007.) Study about possibilities for direct integration of piezo-fibers in sheet metal. In: International Symposium on: Smart Structures and Materials and Nondestructive Evaluation and Health Monitoring, San Diego
Drossel W, Kranz B (2006) Rechnerische Beanspruchungsermittlung bei adaptiven Kompositen mit piezokeramischen Fasern. In: Tagung DVM-Arbeitskreis Zuverlässigkeit mechatronischer und adaptronischer Systeme 1, Darmstadt, pp S. 43–52
Kranz B, Drossel W (2007) Berechnungsmodell für das elektro-mechanische Verhalten flächigen Piezofaser-Metall-Modulen. In: Wissenschaftliches Symposium Transregio PT-PIESA, Chemnitz, pp S.7–11
Gümpel P, Gläser S, Norbert J, Mertmann M, Seitz N, Strittmatter J (2004) Formgedächtnislegierungen: Einsatzmöglichkeiten in Maschinenbau, Medizintechnik und Aktuatorik. Kontakt & Studium, vol 655, expert Verlag, Renningen
Mertmann M (1997) NiTi-Formgedächtnislegierungen für Aktoren der Greifertechnik: Funktionelle Eigenschaften und Optimierung. Grund- und Werkstoffe, vol 5. VDI Verlag GmbH, Düsseldorf
Müller LA, Nowak TE, Völk M (2006) Analyse der periprothetischen femoralen Knochenreaktion nach zementfreier Hüftendoprothetik mittels computertomographiegestützter Osteodensitometrie in vivo: 6-Jahres-Follow-up. Biomed Tech(51):S. 139–144
Couteau B, Hobatho MC, Darmana R, Brignola JC, Arlaud JY (1998) Finite element modelling of the vibrational behaviour of the human femur using CT-based individualized geometrical and material properties. Journal of Biomechanics(4):pp. 383–386
Rho JY, Hobatho MC, Ashman RB (1995) Relations of mechanical properties to density and CT numbers in human bone. Med Eng Phys 17(5):347–355
Acknowledgements
The works presented in Chaps. 3.2 and Chaps. 3.3 were funded by the European Regional Development Fund (ERDF) and the Saxon Ministry of Science and Fine Arts. The works presented in Chap. 3.3 were funded by the internal program MEF from the Fraunhofer-Gesellschaft.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Neugebauer, R. et al. (2013). Topology-Optimized Implants: Medical Requirements and Partial Aspects of a Design Engineering Process Chain. In: Schuh, G., Neugebauer, R., Uhlmann, E. (eds) Future Trends in Production Engineering. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-24491-9_4
Download citation
DOI: https://doi.org/10.1007/978-3-642-24491-9_4
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-24490-2
Online ISBN: 978-3-642-24491-9
eBook Packages: EngineeringEngineering (R0)