Abstract
Magnetic Particle Imaging in general applies two different types of magnetic field geometries in order to obtain information about the spatial distribution of magnetic nanoparticles. First, a static gradient field called selection field is used for spatial encoding. It either provides a field free point or a field free line. Second, additional uniform drive fields are superimposed to steer the field free region through the field of view. Most efficiently, the latter fields are orientated perpendicularly to each other. For field generation, current carrying coils are used, while the static field generation may be supported by strong permanent magnets. In this contribution, discs carrying circular current distributions are investigated for generating both types of field geometries. These distributions are optimized with respect to the achieved field quality as well as to the total power loss.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Gleich, B., Weizenecker, J.: Tomographic imaging using the nonlinear response of magnetic particles. Nature 435, 1214–1217 (2005)
Knopp, T., Erbe, M., Biederer, S., Sattel, T.F., Buzug, T.M.: Efficient generation of a magnetic field-free line. Medical Physics 37(7), 3538–3540 (2010)
Goodwill, P.W., Scott, G.C., Stang, P.P., Conolly, S.M.: Narrowband Magnetic Particle Imaging. IEEE Trans. Med. Imag. 28(8), 1231–1237 (2009)
Rahmer, J., Weizenecker, J., Gleich, B., Borgert, J.: Signal encoding in magnetic particle imaging: properties of the system function. BMC Medical Imaging 9(4) (2009)
Schomberg, H.: Magnetic Particle Imaging: Model and Reconstruction. In: IEEE International Symposium on Biomedical Imaging From Nano to Macro, pp. 992–995 (2010)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag GmbH Berlin Heidelberg
About this paper
Cite this paper
Sattel, T.F., Erbe, M., Buzug, T.M. (2012). Optimization of Circular Current Distributions for Magnetic Field Generation in MPI: A Comparison of the Selection Field Coil and the Drive Field Coil Geometry. In: Buzug, T., Borgert, J. (eds) Magnetic Particle Imaging. Springer Proceedings in Physics, vol 140. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-24133-8_50
Download citation
DOI: https://doi.org/10.1007/978-3-642-24133-8_50
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-24132-1
Online ISBN: 978-3-642-24133-8
eBook Packages: Physics and AstronomyPhysics and Astronomy (R0)