Skip to main content

A Novel Phantom for Accurate Performance Assessment of Bone Mineral Measurement Techniques: DEXA and QCT

  • Conference paper
  • 159 Accesses

Part of the book series: IFMBE Proceedings ((IFMBE,volume 35))

Abstract

accurate performance assessment of bone mineral densitometry is crucial due to the fact a high level of exact estimation of bone situation is needed for correct diagnosis of patient with bone disease. Variation of parameters like sensitivity and percentage error which highly affect the densitometry results may induce some level of uncertainty in diagnosis procedure. So, determination of this variation and designing an algorithm for correction is necessary to assure examiners about measurement results. In this study some phantoms consisting of soft tissue- and bone-equivalent material was devised to accurately test bone densitometry systems. It should be noted that there is no unique phantom to be able to use for simulations evaluation of both DEXA and QCT, this is the main background of this study which aim to design a completed phantom. Four inserts in spine phantom with precisely wide range of K2HPO4 simulate trabecular bone, and provide the basis for the accurately check of bone densitometry systems. It has shown, although a linear correlation between measured and true density can be observed but, there is a variation in sensitivity and percentage error when density of spine changes. To correct and stabilize the sensitivity variation, an analytical algorithm is proposed.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Emami, A. et al. (2011). A Novel Phantom for Accurate Performance Assessment of Bone Mineral Measurement Techniques: DEXA and QCT. In: Osman, N.A.A., Abas, W.A.B.W., Wahab, A.K.A., Ting, HN. (eds) 5th Kuala Lumpur International Conference on Biomedical Engineering 2011. IFMBE Proceedings, vol 35. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-21729-6_17

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-21729-6_17

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-21728-9

  • Online ISBN: 978-3-642-21729-6

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics