Abstract
The analysis of large-scale simulation data from virtual populations can be effective to gain computational insight into disease mechanisms and treatment strategies, which can serve for generating hypotheses for and focusing subsequent clinical trials. This can be instrumental in shortening the critical path in medical product development and more cost-effective clinical trials. A previously published pipeline established point correspondence among volumetric meshes to enable meaningful statistics on cardiac electrophysiological simulations on the anatomical distribution of a large-scale virtual population. Thin Plate Splines (TPS), derived from surface deformations, were used to warp a template volumetric mesh, removing the costly operation of repeated volumetric meshing from the pipeline, but potentially at the cost of the volumetric mesh quality. In this work we compare (1) the influence of using TPS versus volumetric meshing of deformed surface meshes, and (2) the influence of surface mesh subsampling prior to the TPS computation. Our results suggest that warping of a template volumetric mesh introduces errors in electrophysiological simulation results of around 4 ms, while having computational times per mesh on the order of seconds, at surface subsampling rates of up to 80%.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Yu, C.-M., Fung, J.W.-H., Zhang, Q., Sanderson, J.E.: Understanding nonresponders of cardiac resynchronization therapy – current and future perspectives. J. Cardiovasc. Electrophysiol. 16(10), 1117–1124 (2005)
Hoogendoorn, C., Pashaei, A., Sebastián, R., Sukno, F.M., Cámara, O., Frangi, A.F.: Influence of geometric variations on LV activation times: A study on an atlas-based virtual population. In: Camara, O., Pop, M., Rhode, K., Sermesant, M., Smith, N., Young, A. (eds.) STACOM 2010. LNCS, vol. 6364, pp. 242–251. Springer, Heidelberg (2010)
Bookstein, F.L.: Principal warps: Thin-plate splines and the decomposition of deformations. IEEE Trans. Pattern Anal. Mach. Intell. 11(6), 567–585 (1989)
Lamata, P., Niederer, S., Barber, D., Norsletten, D., Lee, J., Hose, R., Smith, N.: Personalization of cubic hermite meshes for efficient biomechanical simulations. In: Jiang, T., Navab, N., Pluim, J.P.W., Viergever, M.A. (eds.) MICCAI 2010. LNCS, vol. 6362, pp. 380–387. Springer, Heidelberg (2010)
Camara, O., Schweiger, M., Scahill, R.I., Crum, W.R., Sneller, B.I., Schnabel, J.A., Ridgway, G.R., Cash, D.M., Hill, D.L.G., Fox, N.C.: Phenomenological model of diffuse global and regional atrophy using finite-element methods. IEEE Trans. Med. Imaging 25(11), 1417–1430 (2006)
Barber, D.C., Oubel, E., Frangi, A.F., Hose, D.R.: Efficient computational fluid dynamics mesh generation by image registration. Med. Image Anal. 11(6), 648–662 (2007)
Streeter, D.D.: Gross morphology and fiber geometry of the heart. In: Berne, R.M., Sperelakis, N., Geigert, S.R. (eds.) Handbook of Physiology: The Cardiovascular System. The Heart, vol. I, pp. 61–112. American Physiology Society (1979)
Caldwell, B.J., Trew, M.L., Sands, G.B., Hooks, D.A., LeGrice, I.J., Smaill, B.H.: Three distinct directions of intramural activation reveal nonuniform side-to-side electrical coupling of ventricular myocytes. Circ. Arrhythm. Electrophysiol. 2(4), 433–440 (2009)
Schroeder, W.J., Zarge, J.A., Lorensen, W.E.: Decimation of triangle meshes. In: Proc. ACM SIGGRAPH, pp. 65–70 (1992)
Lindstrom, P.: Out-of-core simplification of large polygonal models. In: Proc. ACM SIGGRAPH, pp. 259–262 (2000)
Eldar, Y., Lindenbaum, M., Porat, M., Zeevi, Y.Y.: The farthest point strategy for progressive image sampling. IEEE Trans. Image Process. 6(9), 1305–1315 (1997)
Durrer, D., van Dam, R.T., Freud, G.E., Janse, M.J., Meijler, F.L., Arzbaecher, R.C.: Total excitation of the isolated human heart. Circulation 41(6), 899–912 (1970)
Sethian, J.A.: A fast marching level set method for monotonically advancing fronts. Proc. Natl. Acad. Sci. USA 93(4), 1591–1595 (1996)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2011 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Hoogendoorn, C., Pashaei, A., Sebastian, R., Sukno, F.M., Cámara, O., Frangi, A.F. (2011). Sensitivity Analysis of Mesh Warping and Subsampling Strategies for Generating Large Scale Electrophysiological Simulation Data. In: Metaxas, D.N., Axel, L. (eds) Functional Imaging and Modeling of the Heart. FIMH 2011. Lecture Notes in Computer Science, vol 6666. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-21028-0_53
Download citation
DOI: https://doi.org/10.1007/978-3-642-21028-0_53
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-21027-3
Online ISBN: 978-3-642-21028-0
eBook Packages: Computer ScienceComputer Science (R0)