High energy photon therapy beam from the 50 MV racetrack microtron has been evaluated using the Monte Carlo code MCNP4B. The spatial and energy distribution of photons, radial and depth dose distributions in the phantom are calculated for the stationary and scanned photon beams from different targets. The calculated dose distributions are compared to the experimental data using a silicon diode detector. Measured and calculated depth-dose distributions are in fairly good agreement, within 2-3% for the positions in the range 2-30 cm in the phantom, whereas the larger discrepancies up to 10% are observed in the dose build-up region. For the stationary beams the differences in the calculated and measured radial dose distributions axe about 2-10%.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
J. Briesmeister: MCNP™-A general Monte Carlo N-Particle Transport Code Version 4B, LA-12625-M, Los Alamos National Laboratory (1997)
J.J. DeMarco, T.D. Solberg, J.B. Smathers: Med. Phys. 25, 1 (1998)
T.D. Solberg, J.J. DeMarco et al.: Radioth. Oncol. 49, 73 (1998)
A.E. Schach von Wittenau, L.J. Cox et al.: Med. Phys. 26, 1196 (1999)
R.D. Lewis, S.J.S. Ryde et al.: Phys. Med. Biol. 44, 1219 (1999)
J.V. Siebers, P.J. Keall et al.: Phys. Med. Biol. 44, 3009 (1999)
I. Chetty, J.J. DeMarco, T.D. Solberg: Med. Phys. 27, 166 (2000)
J.V. Siebers, P.J. Keall et al.: Phys. Med. Biol. 45, 983 (2000)
P.A. Love, D.G. Lewis et al.: Phys. Med. Biol. 43, 1351 (1998)
J.J. DeMarco, T.D. Solberg et al.: Med. Phys. 22, 11 (1995)
D.P. Gierga, K.J. Adams: Electron/Photon verification calculations using MCNP4B, LA-13440, Los Alamos National Laboratory (1999)
W.R. Nelson, H. Hirayama, D.W.O. Rogers: The EGS4 Code System, Report SLAC-265, Stanford, CA: Stanford Linear Accelerator Center (1985)
A. Brahme, T. Kraepelien, H. Svensson: Acta Radiol. Oncol. 19, 305 (1980)
H. G. Hughes: Treating electron transport in MCNP™, http://www-xdiv.lanl.gov/XCI/PROJECTS/MCNP
R. Svensson, A. Brahme: Phys. Med. Biol., 41, 1353 (1996)
G. Rikner: Acta Radiol. Oncol. 24, 65 (1985)
A. Sät herberg, P. Andreo, M. Karlsson: Med. Phys. 23, 495 (1996)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2001 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Gudowska, I., Sorcini, B., Svensson, R. (2001). Evaluation of a 50-MV Photon Therapy Beam from a Racetrack Microtron Using MCNP4B Monte Carlo Code. In: Kling, A., Baräo, F.J.C., Nakagawa, M., Távora, L., Vaz, P. (eds) Advanced Monte Carlo for Radiation Physics, Particle Transport Simulation and Applications. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-18211-2_50
Download citation
DOI: https://doi.org/10.1007/978-3-642-18211-2_50
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-62113-0
Online ISBN: 978-3-642-18211-2
eBook Packages: Springer Book Archive