Skip to main content

Biomechanical Differences of Coflex-F and Pedicle Screw Fixation in Stabilization of TLIF or ALIF Condition - A Finite Element Study

  • Conference paper
6th World Congress of Biomechanics (WCB 2010). August 1-6, 2010 Singapore

Part of the book series: IFMBE Proceedings ((IFMBE,volume 31))

  • 220 Accesses

Abstract

Lumbar interbody fusion is a common procedure for treating lower back pain related to degenerative disc diseases. The Coflex-F is a recently developed interspinous spacer, the makers of which claim that it can provide stabilization similar to pedicle screw fixation. Therefore, this study compares the biomechanical behavior of the Coflex-F device and pedicle screw fixation with transforaminal lumbar interbody fusion (TLIF) or anterior lumbar interbody fusion (ALIF) surgeries. This study used a validated three-dimensional finite element model of the L1-L5 lumbar intact spine. To simulate TLIF surgery, left lateral total facetectomy and partial discectomy were performed at the L3/L4 segment of this intact model. An AVS-TL moon cage (Stryker Orthopaedics) was implanted in the L3/L4 segment and using a Coflex-F device or pedicle screw fixation. To simulate ALIF surgery, partial discectomy and total nuclectomy were performed at the L3/L4 segment of this intact model. A SynCage-Open cage (Synthes Spine, Inc.) was implanted into the L3/L4 segment and combined with a Coflex-F device or pedicle screw fixation. A 400 N follower load and a 10 Nm moment were applied to the intact model to mimic four physiological motions. All four implanted models were subjected to 400 N follower load and specific moments in accordance with the hybrid test method. The results show that the Coflex-F device combined with ALIF surgery can provide stability similar to that of pedicle screw fixation combined with TLIF or ALIF surgery. Also, both the posterior instrumentations (Coflex-F and pedicle screw fixation) combined with TLIF surgery had lower stability than combined with ALIF surgery.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 International Federation for Medical and Biological Engineering

About this paper

Cite this paper

Lo, C.C., Tsai, K.J., Zhong, Z.C., Hung, C. (2010). Biomechanical Differences of Coflex-F and Pedicle Screw Fixation in Stabilization of TLIF or ALIF Condition - A Finite Element Study. In: Lim, C.T., Goh, J.C.H. (eds) 6th World Congress of Biomechanics (WCB 2010). August 1-6, 2010 Singapore. IFMBE Proceedings, vol 31. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-14515-5_144

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-14515-5_144

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-14514-8

  • Online ISBN: 978-3-642-14515-5

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics