Ideal Observer Comparison between Tomographic and Projection x-Ray Images of the Breast

  • John M. Boone
  • Nathan J. Packard
  • Craig K. Abbey
Part of the Lecture Notes in Computer Science book series (LNCS, volume 6136)

Abstract

The image data from 348 breast CT studies performed on patient volunteers in a Phase II clinical trial were used in a pre-whitened matched filter (PWMF) model observer study. This computer-based investigation simulated the addition of spherical lesions of various diameters to the breast data sets, and a series of images with different slice thicknesses ranging from 0.3 mm to 44 mm were created by voxel averaging. The PWMF was tailored to each slice thickness, and signal known exactly receiver operating characteristic analysis was performed. A total of 1000 lesions and “non-lesions” were simulated for each diameter on each breast data set. Receiver operating characteristic (ROC) curve analysis was performed, and sensitivity at 95% specificity was computed. Thin slice imaging as with breast CT demonstrated significantly better sensitivity than thick slice images as with mammography, with improvements in sensitivity ranging from 5% to 50%.

Keywords

Breast CT Ideal Observers Receiver Operating Characteristic Curves 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Boone, J.M., Nelson, T.R., Lindfors, K.K., Seibert, J.A.: Dedicated breast CT: Radiation dose and image quality evaluation. Radiology 221, 657–667 (2001)CrossRefGoogle Scholar
  2. Boone, J.M., Shah, N., Nelson, T.R.: A comprehensive analysis of DgNCT coefficients for pendant-geometry cone-beam breast computed tomography. Medical Physics 31, 226–235 (2004)CrossRefGoogle Scholar
  3. Kwan, A.L.C., Boone, J.M., Shah, N.: Evaluation of x-ray scatter properties in a dedicated cone-beam breast CT scanner. Med. Phys. 32, 2967–2975 (2005)CrossRefGoogle Scholar
  4. Boone, J.M., Kwan, A.L.C., Seibert, J.A., Shah, N., Lindfors, K.K.: Technique factors and their relationship to radiation dose in pendant geometry breast CT. Med. Phys. 32, 3767–3776 (2005)CrossRefGoogle Scholar
  5. Yang, K., Kwan, A.L.C., Miller, D.F., Boone, J.M.: A general geometric calibration method for cone beam CT systems. Med. Phys. 33, 1695–1706 (2006)CrossRefGoogle Scholar
  6. Boone, J.M., Lindfors, K.K.: Breast CT: potential for breast cancer screening and diagnosis. Future Oncol. 2, 351–356 (2006)CrossRefGoogle Scholar
  7. Boone, J.M., Kwan, A.L., Yang, K., Burkett, G.W., Lindfors, K.K., Nelson, T.R.: Computed tomography for imaging the breast. J. Mamary Gland Biol. Neoplasia 11, 103–111 (2006)CrossRefGoogle Scholar
  8. Yang, K., Kwan, A.L.C., Boone, J.M.: Computer modeling of the spatial resolution properties of a dedicated breast CT scanner. Med. Phys. 34(6), 2059–2069 (2006)CrossRefGoogle Scholar
  9. Kwan, A.L.C., Boone, J.M., Yang, K., Huang, S.Y.: Evaluation of the spatial resolution characteristics of a cone-beam breast CT scanner. Med. Phys. 34(1), 275–281 (2007)CrossRefGoogle Scholar
  10. Lindfors, K.K., Boone, J.M., Nelson, T.R., Yang, K., Kwan, A.L.C., Miller, D.W.: Dedication breast CT: Initial clinical experience. Radiology 246, 725–733 (2008)CrossRefGoogle Scholar
  11. Nelson, T.R., Cervino, L.I., Boone, J.M., Lindfors, K.K.: Classification of breast computed tomography data. Med. Phys. 35, 1078–1086 (2008)CrossRefGoogle Scholar
  12. Huang, S.-Y., Boone, J.M., Yang, K., Kwan, A.L.C., Packard, N.: Evaluation of breast skin thickness from 46 dedicated breast CT examinations. Med. Phys. 35, 1199–1206 (2008)CrossRefGoogle Scholar
  13. Xia, J.Q., Lo, J.Y., Yang, K., Floyd Jr., C.E., Boone, J.M.: Dedicated breast computed tomography: volume image denoising via a partial-diffusion equation based technique. Med. Phys. 35, 1950–1958 (2008)CrossRefGoogle Scholar
  14. Metheany, K.G., Abbey, C.K., Packard, N., Boone, J.M.: Characterizing anatomical variability in breast CT images. Med. Phys. 35, 4685–4694 (2008)CrossRefGoogle Scholar
  15. Yang, K., Kwan, A.L.C., Huang, S.-Y., Packard, N.J., Boone, J.M.: Noise power properties of a cone-beam CT system for breast cancer detection. Med. Phys. 35, 5317–5327 (2008)CrossRefGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2010

Authors and Affiliations

  • John M. Boone
    • 1
  • Nathan J. Packard
    • 1
  • Craig K. Abbey
    • 2
  1. 1.Department of RadiologyUniversity of California DavisSacramentoUSA
  2. 2.Department of PsychologyUniversity of California Santa BarbaraSanta BarbaraUSA

Personalised recommendations