Abstract

The strength of nuclear imaging is based on its ability to reveal quantitative information. Especially positron emission tomography (PET) offers, as long as all corrections, such as for photon attenuation, scatter and partial volume effect are applied, highly quantitative data. This chapter describes the different pitfalls in PET image analysis and necessary correction methods to yield quantitative images. Furthermore, it provides practical recipes for quantitative image analysis.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   179.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  • Ostertag H et al (1989) Measured attenuation correction methods. Eur J Nucl Med 15(11):722–726

    Article  PubMed  CAS  Google Scholar 

  • Srinivas SM et al (2009) A recovery coefficient method for partial volume correction of PET images. Ann Nucl Med 23(4):341–348

    Article  PubMed  Google Scholar 

  • Townsend DW (2001) A combined PET/CT scanner: the choices. J Nucl Med 42(3):533–534

    PubMed  CAS  Google Scholar 

  • Weber WA, Schwaiger M, Avril N (2000) Quantitative assessment of tumor metabolism using FDG-PET imaging. Nucl Med Biol 27(7):683–687

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Martin S. Judenhofer .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Judenhofer, M.S., Wiehr, S., Kukuk, D., Fischer, K., Pichler, B.J. (2011). Guidelines for Nuclear Image Analysis. In: Kiessling, F., Pichler, B. (eds) Small Animal Imaging. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-12945-2_26

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-12945-2_26

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-12944-5

  • Online ISBN: 978-3-642-12945-2

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics