New Adaptive Servo-Ventilation Device for Cheyne–Stokes Respiration

  • Ken-ichi Maeno
  • Takatoshi KasaiEmail author
Chapter

Abstract

Several studies have shown that patients with congestive heart failure (CHF) often suffer from the complication of sleep-disordered breathing (SDB), including Cheyne–Stokes respiration with central sleep apnea (CSR-CSA) as well as obstructive sleep apnea (OSA). These two types of SDB often coexist in such cases. CSR-CSA is characterized by cyclical recurrence of central apneas and hyperpneas with waxing and waning of the flow amplitude, which results from instability of the respiratory control system characterized by a tendency to hyperventilate due to the heart failure condition. Central apnea occurs when the Paco2 falls below the apnea threshold during sleep due to ventilatory overshoot. CSR-CSA is modifiable by several types of positive airway pressure (PAP) therapy; however, in the clinical setting, CSR-CSA patients with CHF tend to have poor adherence to the conventional PAP therapies, especially continuous PAP (CPAP), which are well established as treatments for OSA. Furthermore, they are well known to be “nonresponders” to conventional PAP as a therapy for CSR-CSA. In the CANPAP (Canadian Continuous Positive Airway Pressure for Patients with Central Sleep Apnea and Heart Failure Trial) study [1], CPAP only decreased the average apnea–hypopnea index (AHI) by about 50% (from 40 to 19/h). The post hoc analysis of the CANPAP. study [2] showed subjects with a residual CSR-CSA of AHI ≥ 15 using CPAP remained with a poor prognosis. These data suggest that other treatment options that can suppress the CSR-CSA more effectively (i.e., AHI < 15) and can produce better compliance are needed.

Keywords

Obstructive Sleep Apnea Positive Airway Pressure Pressure Support Central Sleep Apnea Central Apnea 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. 1.
    Bradley TD, Logan AG, Kimoff RJ et al (2005) Continuous positive airway pressure for central sleep apnea and heart failure. N Engl J Med 353:2025–2033PubMedCrossRefGoogle Scholar
  2. 2.
    Arzt M, Floras JS, Logan AG et al (2007) Suppression of central sleep apnea by continuous positive airway pressure and transplant-free survival in heart failure: a post hoc analysis of the Canadian Continuous Positive Airway Pressure for Patients with Central Sleep Apnea and Heart Failure Trial (CANPAP). Circulation 115:3173–3180PubMedCrossRefGoogle Scholar
  3. 3.
    Teschler H, Döhring J, Wang YM et al (2001) Adaptive pressure support servo-ventilation: a novel treatment for Cheyne–Stokes respiration in heart failure. Am J Respir Crit Care Med 164:614–619PubMedGoogle Scholar
  4. 4.
    Kasai T, Narui K, Dohi T et al (2006) First experience of using new adaptive servo-ventilation device for Cheyne–Stokes respiration with central sleep apnea among Japanese patients with congestive heart failure: report of 4 clinical cases. Circ J 70:1148–1154PubMedCrossRefGoogle Scholar
  5. 5.
    Arzt M, Wensel R, Montalvan S et al (2008) Effects of dynamic bilevel positive airway pressure support on central sleep apnea in men with heart failure. Chest 134:61–66PubMedCrossRefGoogle Scholar
  6. 6.
    Oldenburg O, Schmidt A, Lamp B et al (2008) Adaptive servoventilation improves cardiac function in patients with chronic heart failure and Cheyne–Stokes respiration. Eur J Heart Fail 10:581–586PubMedCrossRefGoogle Scholar
  7. 7.
    Pepperell JC, Maskell NA, Jones DR et al (2003) A randomized controlled trial of adaptive ventilation for Cheyne–Stokes breathing in heart failure. Am J Respir Crit Care Med 168:1109–1114PubMedCrossRefGoogle Scholar
  8. 8.
    Philippe C, Stoïca-Herman M, Drouot X et al (2006) Compliance with and effectiveness of adaptive servoventilation versus continuous positive airway pressure in the treatment of Cheyne–Stokes respiration in heart failure over a six month period. Heart 92:337–342PubMedCrossRefGoogle Scholar
  9. 9.
    De Hoyos A, Liu PP, Benard DC et al (1995) Haemodynamic effects of continuous positive airway pressure in humans with normal and impaired left ventricular function. Clin Sci (Lond) 88:173–178Google Scholar
  10. 10.
    Kasai T, Dohi T, Maeno K et al (2009) Impact of adaptive servo ventilation in heart failure patients with central sleep apnea which is not sufficiently treated with continuous positive airway pressure [abstract]. Am J Respir Crit Care Med 179:A5336Google Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2010

Authors and Affiliations

  1. 1.Sleep CenterToranomon HospitalTokyoJapan
  2. 2.Department of CardiologyJuntendo University, School of MedicineTokyoJapan

Personalised recommendations