The automation and speedup of interventional therapy and diagnostic workflows is a crucial issue. One way to improve these workflows is to accelerate the image acquisition procedures by fully automating the patient setup. This paper describes a system that performs this task without the use of markers or other prior assumptions. It returns metric coordinates of the 3-D body shape in real-time for inverse positioning. This is achieved by the application of an emerging technology, called Time-of-Flight (ToF) sensor. A ToF sensor is a cost-efficient, off-the-shelf camera which provides more than 40,000 3-D points in real-time. The first contribution of this paper is the incorporation of this novel imaging technology (ToF) in interventional imaging. The second contribution is the ability of a C-arm system to position itself with respect to the patient prior to the acquisition. We are using the 3-D surface information of the patient to partition the body into anatomical sections. This is achieved by a fast two-stage classification process. The system computes the ISO-center for each detected region. To verify our system we performed several tests on the ISO-center of the head. Firstly, the reproducibility of the head ISO-center computation was evaluated. We achieved an accuracy of (x: 1.73±1.11 mm/y: 1.87±1.31 mm/z: 2.91±2.62 mm). Secondly, a C-arm head scan of a body phantom was setup. Our system automatically aligned the ISO-center of the head with the C-arm ISO-center. Here we achieved an accuracy of ± 1 cm, which is within the accuracy of the patient table control.
The authors gratefully acknowledge funding of the International Max-Planck-Research-School for Optics and Imaging (IMPRS-OI) and the Erlangen Graduate School in Advanced Optical Technologies (SAOT) by the German National Science Foundation (DFG) in the framework of the excellence initiative. We also thank the Siemens AG, Health Care Sector, Forchheim, Germany for supporting this work.
Chapter PDF
Similar content being viewed by others
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
Strobel, N., Meissner, O., Boese, J., Brunner, T., Heigl, B., Hoheisel, M., Lauritsch, G., Nagel, M., Pfister, M., Rúhrnschopf, E.-P., Scholz, B., Schreiber, B., Spahn, M., Zellerhoff, M., Klingenbeck-Regn, K.: 3D Imaging with Flat-Detector C-Arm Systems, 3rd edn., pp. 33–51. Springer, Heidelberg (2009)
Grimson, W.E.L., Leventon, M.E., Ettinger, G., Chabrerie, A., Ozlen, F., Nakajima, S., Atsumi, H., Kikinis, R., Black, P.: Clinical experience with a high precision image-guided neurosurgery system. In: Wells, W.M., Colchester, A.C.F., Delp, S.L. (eds.) MICCAI 1998. LNCS, vol. 1496, pp. 63–73. Springer, Heidelberg (1998)
Navab, N., Wiesner, S., Benhimane, S., Euler, E., Heining, S.M.: Visual servoing for intraoperative positioning and repositioning of mobile C-arms. In: Larsen, R., Nielsen, M., Sporring, J. (eds.) MICCAI 2006. LNCS, vol. 4190, pp. 551–560. Springer, Heidelberg (2006)
Wang, L., Traub, J., Heining, S.M., Benhimane, S., Euler, E., Graumann, R., Navab, N.: Long bone X-ray image stitching using camera augmented mobile C-arm. In: Metaxas, D., Axel, L., Fichtinger, G., Székely, G. (eds.) MICCAI 2008, Part II. LNCS, vol. 5242, pp. 578–586. Springer, Heidelberg (2008)
Ladikos, A., Benhimane, S., Navab, N.: Real-time 3D reconstruction for collision avoidance in interventional environments. In: Metaxas, D., Axel, L., Fichtinger, G., Székely, G. (eds.) MICCAI 2008, Part II. LNCS, vol. 5242, pp. 526–534. Springer, Heidelberg (2008)
Xu, Z., Schwarte, R., Heinol, H., Buxbaum, B., Ringbeck, T.: Smart Pixel - Photometric Mixer Device (PMD) / New System Concept of a 3D-Imaging-on-a-Chip. In: 5th International Conference on Mechatronics and Machine Vision in Practice, pp. 259–264 (1998)
Schaller, C., Penne, J., Hornegger, J.: Time-of-Flight Sensor for Respiratory Motion Gating. Medical Physics 35(7), 3090–3093 (2008)
Schaller, C., Adelt, A., Penne, J., Hornegger, J.: Time-of-flight sensor for patient positioning. In: Proceedings of SPIE Medical Imaging 2009: Visualization, Image-guided Procedures and Modeling (2009)
Paris, S., Durand, F.: A fast approximation of the bilateral filter using a signal processing approach. Int. J. Comput. Vision 81(1), 24–52 (2009)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2009 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Schaller, C., Rohkohl, C., Penne, J., Stürmer, M., Hornegger, J. (2009). Inverse C-arm Positioning for Interventional Procedures Using Real-Time Body Part Detection. In: Yang, GZ., Hawkes, D., Rueckert, D., Noble, A., Taylor, C. (eds) Medical Image Computing and Computer-Assisted Intervention – MICCAI 2009. MICCAI 2009. Lecture Notes in Computer Science, vol 5761. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-04268-3_68
Download citation
DOI: https://doi.org/10.1007/978-3-642-04268-3_68
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-04267-6
Online ISBN: 978-3-642-04268-3
eBook Packages: Computer ScienceComputer Science (R0)