Abstract

A control scheme based on physiological parameters for the inflation of an intra-aortic clamping balloon is presented. Automatic volumetric pumps for the inflation of balloon catheter have been largely developed, although the process modelling for catheter mounted balloon’s inflation has never been discussed. Automatic inflation is a key issue for autonomous positioning and navigation of an intra-aortic catheter. This work explores the possibility of modelling the inflation process for a catheter mounted balloon, proposing a first order model. The pole’s position depends by the catheter’s hydraulic resistance and by the sum of the aorta’s and balloon’s compliance. Main advance of this control scheme is the fact of taking into account a physiological parameter, integrating it in the control algorithm. The estimation of the aorta’s compliance can be done either with in-vitro experiments or at the same time while controlling the pump by means of an adaptive control scheme. The scheme was applied to control a volumetric pump and tested in vitro and in vivo, showing a reasonable settling time, rise time and overshoot.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Sette, M.M. et al. (2009). Physiological Parameters Based Control Scheme for Automatic Intravascular Balloon Inflation. In: Dössel, O., Schlegel, W.C. (eds) World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany. IFMBE Proceedings, vol 25/6. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-03906-5_92

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-03906-5_92

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-03905-8

  • Online ISBN: 978-3-642-03906-5

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics