Abstract

In conventional radiation therapy, regarding normal tissue tolerance, the treatment of bulk tumors is one of the remaining challenges. In order to cope with, Grid Radiation Therapy (GRT) is a technique to deliver high doses, approximately 15 - 20 Gy per fraction, to several small volumes located in a large radiation field. This can be performed using a grid block. The current work concentrates on the dosimetric characteristics of a designed mega-voltage grid, used for a unique treatment modality. A square 16 × 16 array grid block was designed and fabricated. Several dosimetric characteristics including: depth dose, Valley To Peak (VTP) ratio, and grid out-put factor were evaluated using a calibrated diode dosimeter for a range of radiation fields. The percent depth dose curves, measured in the presence of grid block, lie within those measured for the corresponding open field and a narrow beam. At the Dmax, the VTP ratio was fond to be within 17% -28%, while these ranges between 23% - 35% at a depth of 10 cm. The grid out-put factor found to be 0.78 and it slightly decreases with increasing of radiation field size. The measured dosimetric characteristics of grid block indicate that the mega-voltage grid therapy can be applied as a possible clinical modality for palliative cases.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Sani, K.Gk. (2009). Evaluation of dosimetric characteristics of a grid block fabricated for Mega-voltage grid therapy purposes. In: Dössel, O., Schlegel, W.C. (eds) World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany. IFMBE Proceedings, vol 25/1. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-03474-9_3

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-03474-9_3

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-03472-5

  • Online ISBN: 978-3-642-03474-9

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics