Effect of Electrode Geometry on Deep Brain Stimulation: Monopolar Point Source vs. Medtronic 3389 Lead

  • Conference paper
25th Southern Biomedical Engineering Conference 2009, 15 – 17 May 2009, Miami, Florida, USA

Part of the book series: IFMBE Proceedings ((IFMBE,volume 24))

Abstract

Deep brain stimulation (DBS) has emerged as an effective treatment for a variety of neurological and movement disorders; however, the fundamental mechanisms by which DBS works are not well understood. Computational models of DBS can be used to gain insights into these fundamental mechanisms and typically require two steps: computation of the electrical potentials generated by DBS and, subsequently, determination of the effects of the extracellular potentials on neurons. The objective of this study was to assess the validity of utilizing the point source approximation versus realistic finite element models (FEMs) in calculating the potentials generated by monopolar DBS. The distributions of extracellular potentials generated in a homogenous isotropic volume conductor were calculated using either the point source approximation or a realistic finite element model of the DBS lead. These extracellular potentials were then coupled to populations of simulated axons, and input-output curves of the number of stimulated axons as a function of stimulation intensity were calculated for different stimulus polarities, pulse durations, and axon orientations (parallel or perpendicular to the electrode). The differences in input-output curves calculated with the point source and FEM were small; FEM-predicted thresholds were on average 4.83% lower than point source predicted thresholds across all the conditions tested. The distance from and location relative to the electrode was the primary factor determining the error between point source and FEM geometries, and larger differences in predicted thresholds were evident in axons located immediately adjacent to the realistic electrode. Thus, under the conditions tested, the point source was a valid approximation for predicting population excitation in response to monopolar DBS. The results of this study reveal new insights that may aid in future computational modeling studies of DBS.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Zhang, T., Grill, W.M. (2009). Effect of Electrode Geometry on Deep Brain Stimulation: Monopolar Point Source vs. Medtronic 3389 Lead. In: McGoron, A.J., Li, CZ., Lin, WC. (eds) 25th Southern Biomedical Engineering Conference 2009, 15 – 17 May 2009, Miami, Florida, USA. IFMBE Proceedings, vol 24. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-01697-4_61

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-01697-4_61

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-01696-7

  • Online ISBN: 978-3-642-01697-4

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics