Contrast Enhancement with Dual Energy CT for the Assessment of Atherosclerosis

  • Stefan C. Saur
  • Hatem Alkadhi
  • Luca Regazzoni
  • Simon Eugster
  • Gábor Székely
  • Philippe Cattin
Conference paper
Part of the Informatik aktuell book series (INFORMAT)

Abstract

A drawback of the commonly used single source computed tomography systems (CT) is that different materials might show very similar attenuation at any selected radiation energy. However, the assessment of atherosclerosis requires good differentiation between vessel lumen, calcium, adipose, and surrounding tissue. Dual energy CT (DECT) simultaneously measures attenuations at two energies and therefore can improve the differentiation to some extent. A tissue cancelation and enhancement algorithm for dual energy data was already proposed in 1981 and evaluated on experimental settings with a stationary X-ray source. For this study, we adapted this algorithm for DECT and propose its usage as a pre-processing step for the assessment of atherosclerosis. On clinical DECT patient data and with fixed parameters we could show a simultaneous contrast enhancement between 8% and 67% among all targeted tissues.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Lehmann LA, Alvarez RE, Macovski A, et al. Generalized image combinations in dual KVP digital radiography. Med Phys. 1981;8(5):659–667.CrossRefGoogle Scholar
  2. 2.
    Marziani M, Taibi A, Tuffanelli A, et al. Dual-energy tissue cancellation in mammography with quasi-monochromatic x-rays. Phys Med Biol. 2002;47(2):305.CrossRefGoogle Scholar
  3. 3.
    Taibi A, Fabbri S, Baldelli P, et al. Dual-energy imaging in full-field digital mammography: A phantom study. Phys Med Biol. 2003;48(13):1945–1956.CrossRefGoogle Scholar
  4. 4.
    Flohr T, McCollough C, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol. 2006;16(2):256–268.CrossRefGoogle Scholar
  5. 5.
    Eusemann C, Holmes III DR, Schmidt B, et al. Dual energy CT: How to best blend both energies in one fused image? Procs SPIE. 2008;6918(l):691803–8.CrossRefGoogle Scholar
  6. 6.
    Johnson T, Krauß B, Sedlmair M, et al. Material differentiation by dual energy CT: Initial experience. Eur Radiol. 2007;17(6):1510–1517.CrossRefGoogle Scholar
  7. 7.
    del Rio MS, Dejus RJ. XOP: Recent developments. Procs SPIE. 1998;3448(l):340–345.Google Scholar
  8. 8.
    Berger MJ, Hubbel JH. XCOM: Photon Cross Sections Database. National Institute of Standards and Technology; 1998.Google Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2009

Authors and Affiliations

  • Stefan C. Saur
    • 1
  • Hatem Alkadhi
    • 2
  • Luca Regazzoni
    • 1
  • Simon Eugster
    • 1
  • Gábor Székely
    • 1
  • Philippe Cattin
    • 1
    • 3
  1. 1.Computer Vision LaboratoryETH ZurichSwitzerland
  2. 2.Institute of Diagnostic RadiologyUniversity Hospital ZurichSwitzerland
  3. 3.Medical Image Analysis CenterUniversity of BaselSwitzerland

Personalised recommendations