Skip to main content

Onset Voltage of Corona in Electrostatic Filters as Influenced by Gas Flow

  • Conference paper

Abstract

The onset voltage of negative corona on the discharge wire in wire-duct filters is calculated based on the criterion for the recurrence of negative corona (Trichel) pulses. The negative corona pulse corresponds to one electron avalanche followed by its successors in the ionization-zone surrounding the wire. The growth of avalanches and their successors depends on the electric field and the pressure. With gas flow in the filter, the pressure is different from the atmospheric value with a subsequent change of the onset voltage. The onset voltage is determined at different value of gas flow velocity. The obtained results are discussed in the light of gas discharge physics.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   549.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD   699.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. J. Bohm. Electrostatic Precipitators. New York, Elsevier, 1982.

    Google Scholar 

  2. J. Mclean. Electrostatic Precipitators. IEE Proc., Vol. 135, pt. A, No. 6, 347–361, 1988.

    CAS  Google Scholar 

  3. J. R. Mcdonald, W. B. Smith, H. W. Spencer and L. E. Sparks. A mathematical model for calculating electrical conditions in wire-duct electrostatic precipitation devices. J. Appl. Phys. Vol. 48, 2231–2243, 1977.

    Article  Google Scholar 

  4. Singer, H. Steinbigler and P. weiss. A charge simulation method for the calculation of high voltage fields. IEEE Trans., Vol. PAS-93, 1660–1668, 1974.

    Google Scholar 

  5. M. Abdel-salam and D. Wiitanen. Calculation of corona onset voltage for duct-type precipitators. IEEE Trans. Industry Applications, Vol. 29, No. 2, 274–280, 1993.

    Article  Google Scholar 

  6. A.K. Jain. Fluid Mechanics. Khanna Publishers, Delhi, India, 1996.

    Google Scholar 

  7. M. Khalifa, M. Abdel-salam and M. Abou-Seada Calculation of negative corona onset voltages, IEEE Paper #C-73-160-9, 1973.

    Google Scholar 

  8. A. A. Elmoursi and G. S. P. Castle. Modeling of corona characteristics in wire-duct precipitator using the charge simulation technique. IEEE trans. Industry Applications, Vol. 23, 95–102, 1984.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Zhejiang University Press, Hangzhou and Springer-Verlag GmbH Berlin Heidelberg

About this paper

Cite this paper

Abdel-Salam, M., Hashem, A. (2009). Onset Voltage of Corona in Electrostatic Filters as Influenced by Gas Flow. In: Yan, K. (eds) Electrostatic Precipitation. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-89251-9_25

Download citation

Publish with us

Policies and ethics