Abstract
An integration of low power operated Surface Acoustic Wave (SAW) devices with the electrostatic microactuators for microfluidic and similar applications is presented in this chapter. Passive, low power, and small area devices can be interrogated wirelessly using SAW devices, which can respond to a uniquely coded signal for a secure and reliable operation. The novel approach relies on converting the interrogating coded signal to surface acoustic wave that is then correlated with an embedded code. A theoretical analysis of how the actuation mechanism operates is carried out and simulation results of the new microactuator are discussed. At the initial analytical stage, for simplicity, a basic SAW delay line structure is used to generate an electrostatic field between output interdigital transducer (IDT) of the SAW device and a thin conductive plate (actuator), which is placed on top of the output IDT. The static and transient displacement analysis of the actuator is carried out using ANSYS simulation tools. A comparison between the static displacements obtained from ANSYS based simulations and Rayleigh-Ritz based analysis is also presented and discussed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Dissanayake D, Tikka A, Al-Sarawi S, Abbott D (2006) Radio frequency controlled microvalve for biomedical applications. In: Proc. SPIE–Smart Materials IV, 6413, Australia, 64130, pp 1–13
Varadan V K, Varadan V V (2000) Microsensors, micromechanical systems (MEMS), and electronics for smart structures and systems. Smart Materials and Structures, 9:953–972
Wixforth A (2003) Acoustically driven planar microfluidics. Superlattices and Microstructures, 6:389–396
Strobl C J, Guttenberg Z V, Wixforth A (2004) A Nano–and pico-dispensing of fluids on planar substrates using SAW. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 51(11):1432–1436
Jones I, Ricciardi L, Hall L, Hansen H, Varadan V, Bertram C, Maddocks S, Enderling S, Saint D, Al-Sarawi S, Abbott D (2007) Wireless RF communication in biomedical applications. Smart Materials and Structures, 17 015050 (10pp)
Subramanian H, Varadan V K, Varadan V V, Vellekoopz M J (1997) Design and fabrication of wireless remotely readable MEMS based microaccelerometers. Smart Materials and Structures, 6(6):730–738
Milstein L B, Das P (1979) Surface acoustic wave devices. IEEE Communications Magazine, 17:25–33
Gardner J W, Varadan V K, Awadelkarim O O (2001) Microsensors, MEMS, and Smart Devices. Tsinghua University Press, Beijing
Gantner A, Hoppe R H W, Köster D, Siebert K G, Wixforth A (2005) Numerical simulation of piezoelectrically agitated surface acoustic waves on microfluidic biochips. http://www.opus-bayern.de/uni-augsburg/volltexte/2005/142/, visited on 14/02/2008
Kannan T (2006) Finite element analysis of surface acoustic wave resonators. MA thesis, University of Saskatchewan
Maugin G A (1985) Nonlinear electromechanical effects and applications. World Scientific Publishing Co Pty Ltd, Singapore
Adler E L (2000) Bulk and surface acoustic waves in anisotropic solids. International Journal of High Speed Electronics and Systems, 10(3):653–684
Ippolito S J, Kalantar-zadeh K, Wlodarski W, Powell D A (2002) Finite-element analysis for simulation of layered SAW devices with XY LiNbO3 substrate Proc. In: SPIE–Smart Structures, Devices, and Systems, 4935, Australia, pp 120–131
Skinner J L, Cardinale G F, Talin A A, Brocato R W (2006) Effect of critical dimension variation on SAW correlator energy. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 53(2):497–501
ANSYS Incorporation. Home page, http://www.ansys.com/, visited on 14/02/2008
Dissanayake D, Al-Sarawi S, Abbott D (2007) Surface Acoustic Wave Device Based Electrostatic Actuator for Microfluidic Applications. In: Proc. 2nd International Conference on Sensing Technology, Palmerston North, New Zealand, pp 381–386
Dissanayake D W, Al-Sarawi S, Abbott D (2007) Surface Acoustic Wave Device based wireless passive microvalve for microfluidic applications. In: Proc. SPIE–BioMEMS and Nanotechnology III, 6799, 67990H pp 1–10
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2008 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Dissanayake, D.W., Al-Sarawi, S.F., Abbott, D. (2008). Electrostatic Microactuator Design Using Surface Acoustic Wave Devices. In: Mukhopadhyay, S.C., Gupta, G.S. (eds) Smart Sensors and Sensing Technology. Lecture Notes Electrical Engineering, vol 20. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-79590-2_10
Download citation
DOI: https://doi.org/10.1007/978-3-540-79590-2_10
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-79589-6
Online ISBN: 978-3-540-79590-2
eBook Packages: EngineeringEngineering (R0)