Abstract
Attenuation (scattering and absorption) of gamma photons in the patient’s body is one of the major limitations among the others in single photon emission computed tomography (SPECT). It reduces quantitative accuracy of measured radioactivity concentration and causes hot rim artifacts in reconstructed images if not corrected for. A variety of approximate attenuation correction methods has been developed or proposed by various groups to date, but all methods have some limitations. In this paper two attenuation correction methods have been investigated and compared. Data are acquired with both the collimators either LEGP or LEHR by scanning R. A. Carlson cylindrical phantom over 360o with an acrylic block of holes simulating hot regions of various sizes at different locations with respect to the walls of the phantom, which was filled with water and Tc-99m solution was uniformly distributed. Results show that the Chang’s attenuation correction method works better as compared to the Sorenson’s method in terms of the linearity in measured counts in hot regions. However, Chang’s method is sensitive with linear attenuation coefficient values and also gives higher standard deviation values particularly in smaller hot regions count density - with LEHR collimator data - compared to the Sorenson’s method.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Hayashi, M., Deguchi, J., Utsunomiya, K., Yamada, M., Komori, T., Takuchi, M., Kana, K., Narabayashi, I.: Comparison of Methods of Attenuation and Scatter Correction in Brain Perfusion SPECT. Journal of Nuclear Medicine Technology 33, 224–229 (2005)
El Fakhri, G., Kijewski, M.F., Albert, M.S., Johnson, K.A., Moore, S.C.: Quantitative SPECT Leads to Improved Performance in Discrimination Tasks Related to Prodromal Alzheimer’s Disease. J. Nucl. Med. 45, 2026–2031 (2004)
Kim, K.M., Varrone, H., Watabe, H., Shidahara, M., Fujita, M., Innis, R.B., Iida, H.: Contribution of Scatter and Attenuation Compensation to SPECT Images of Nonuniformly Distributed Brain Activities. J. Nucl. Med. 44, 512–519 (2003)
Zaidi, H., Hasegawa, B.: Determination of the Attenuation Map in Emission Tomography. J. Nucl. Med. 44, 291–315 (2003)
Budinger, T.F., Gulberg, G.T., Huesman, R.H.: Emission Computed Tomography. In: Herman, G.T. (ed.) Image reconstruction from projections: implementation and applications, pp. 147–246. Springer, New York (1979)
Gullberg, G.T., Huesman, R.H., Malko, G.A., Plec, N.J., Budinger, T.F.: An attenuated projector-backprojector for iterative SPECT reconstruction. Phy. Med. Bio. 30, 799–816 (1985)
Rosenthal, M.S., Cullom, J., Hawkins, W., Moore, S.C., Tsui, B.M.W., Yester, M.: Quantitative SPECT imaging: A review and recommendations by the Focus Committee of the Society of Nuclear Medicine Computer and Instrumentation Council. J. Nucl. Med. 36, 1489–1513 (1995)
Tanaka, E., Toyama, H., Murayama, H.: Convolutional image reconstruction for quantitative single photon emission computed tomography. Phy. Med. Bio. 29, 1489–1500 (1984)
Glick, S.J., Penney, B.J., King, M.A.: Filtering of SPECT reconstruction made using Bellini’s attenuation correction method: a comparison of three pre-reconstruction and a post reconstruction Wiener filter. IEEE Trans. Nucl. Sci. NS-38, 663–669 (1991)
Liang, Z., Turkington, T.G., Gilland. Jaszczak, R.J., Coleman, R.E.: Simultaneous compensation for attenuation, scatter, and detector response for SPECT reconstruction in three dimensions. Phys. Med. Bio. 37, 587–603 (1992)
Galt, J.R., Cullom, S.J., Garcia, E.V.: SPECT quantification: a simplified method of attenuation correction method for cardiac imaging. J. Nucl. Med. 33, 2232–2237 (1992)
Tung, C.H., Gullberg, G.T., Zeng, G.L., Christian, P.E., Datz, F.L., Morgan, H.T.: Nonuniform attenuation correction using simultaneous transmission and emission converging tomography. IEEE Trans. Nucl. Sci. NS-39, 1134–1143 (1992)
Maze, A., Le Cloirec, J., Collorec, R., Bizais, Y., Braindet, P., Bourguet, P.: Iterative Reconstruction Methods for Nonuniform Attenuation Distribution in SPECT. J. Nucl. Med. 34, 1204–1209 (1993)
Chang, L.T.: A method for attenuation correction in radionuclide computed tomography. IEEE Trans. Nucl. Sci. NS-35, 638–643 (1978)
Walters, T.E., Simon, W., Chesler, D.A., Correia, J.A.: Attenuation correction in gamma emission computed tomography. J. Comp. Asst. Tomogr. 1, 89–94 (1981)
Moore, S.C., Brunelle, J.A., Kirsch, C.: An iterative attenuation correction for a single photon scanning multidetector tomography system. J. Nucl. Med. 22, 65 (1981)
Mas, J., Ben Younes, R., Bidet, R.: Improvement of quantification in SPECT studies by scatter and attenuation compensation. Eur. J. Nucl. Med. 15, 351–356 (1989)
Jaszczak, R.J., Coleman, R.E., Lim, C.B.: Single photon emission computed tomography. IEEE Trans. Nucl. Sci. NS- 27, 1137–1152 (1980)
Faber, T.L., Lewis, M.H., Corbett, J.R., Stokely, E.M.: Attenuation correction for SPECT: An evaluation of Hybrid approaches. IEEE Trans. Medical Imaging MI-3, 101–107 (1984)
Murase, K., Itoh, H., Mogami, H., Ishine, M., Kawamura, M., Iio, A., Hamamoto, K.: A comparative study of attenuation correction algorithms in single photon emission computed tomography (SPECT). Eur. J. Nucl. Med. 13, 55–62 (1987)
Sorenson, J.A.: Methods for quantitative measurement of radioactivity in vivo by whole-body counting. In: Hine, G.J., Sorenson, J.A. (eds.) Instrumentation in Nuclear Medicine, vol. 2, pp. 311–348. Academic Press, New York (1974)
Spinks, T.J., Sayed, I.S.: Effect of lead filters on the performance of a Neuro-PET tomography operated without septa. IEEE Trans. Nucl. Sci. NS-40, 1087–1091 (1993)
Sayed, I.S.: Reduction of Scattered gammas and Attenuation Correction in SPET. Ph D Thesis, King’s College London, University of London (1996)
Tsui, B.M.W., Zhao, X., Frey, E.C., McCartney, W.H.: Quantitative single photon emission computed tomography: basics and clinical considerations. Seminars in Nucl. Med. 24, 38–65 (1994)
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 2008 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Sayed, I.S., Zakaria, A., Nik, N. (2008). Comparison of Chang’s with Sorenson’s Attenuation Correction Method by Varying Linear Attenuation Coefficient Values in Tc-99m SPECT Imaging. In: Gao, X., Müller, H., Loomes, M.J., Comley, R., Luo, S. (eds) Medical Imaging and Informatics. MIMI 2007. Lecture Notes in Computer Science, vol 4987. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-79490-5_27
Download citation
DOI: https://doi.org/10.1007/978-3-540-79490-5_27
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-79489-9
Online ISBN: 978-3-540-79490-5
eBook Packages: Computer ScienceComputer Science (R0)