Abstract
Validation of non-rigid registration methods is still a challenging task. Different evaluation criteria were published, yet no widely accepted gold standard exists. The aim of this paper is to provide quantitative evaluation metrics suited for clinical 3D images containing vessel trees, such as liver or brain data. We present a method to identify corresponding points on different vessel trees by extracting consistent graph minors interactively. Four different metrics based on these correspondencies are proposed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
West J, Fitzpatrick JM, Wang MY, et al. Comparison and evaluation of retrospective intermodality brain image registration techniques. J Comput Assist Tomogr. 1997;21(4):554–66.
Hellier P, Barillot C, Corouge I, et al. Retrospective evaluation of inter-subject brain registration. Proc MICCAI. 2001; p. 258–65.
Christensen G, Geng X, Kuhl J, et al. Introduction to the non-rigid image registration evaluation project (NIREP). Proc WBIR. 2006; p. 128–35.
Reinertsen I, Descoteaux M, Siddiqi K, et al. Validation of vessel-based registration for correction of brain shift. Med Image Anal. 2007;11(4):374–88.
Reinertsen I, Lindseth F, Unsgaard G, et al. Clinical validation of vessel-based registration for correction of brain-shift. Med Image Anal. 2007;11(6):673–84.
Charnoz A, Agnus V, Malandain G, et al. Design of robust vascular tree matching: Validation on liver. Proc IPMI. 2005; p. 443–55.
Rohr K, Stiehl H, Sprengel R, et al. Landmark-Based Elastic Registration Using Approximating Thin-Plate Splines. IEEE Trans Med Imaging. 2001;20(6):526–34.
Lange T, Eulenstein S, Hünerbein M, et al. Augmenting intraoperative 3D ultrasound with preoperative models for navigation in liver surgery. Lect Notes Comp Sci. 2004;3217:534–41.
Lange T, Lamecker H, Hünerbein M, et al. A new class of distance measures for registration of tubular models to image data. Proc BVM. 2007; p. 101–5.
Beller S, Hünerbein M, Eulenstein S, et al. Feasibility of navigated resection of liver tumors using multiplanar visualization of intraoperative 3D ultrasound data. Annal Surg. 2007;246(2):288–94.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2008 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Lange, T., Lamecker, H., Hünerbein, M., Eulenstein, S., Beller, S., Schlag, P.M. (2008). Validation Metrics for Non-rigid Registration of Medical Images Containing Vessel Trees. In: Tolxdorff, T., Braun, J., Deserno, T.M., Horsch, A., Handels, H., Meinzer, HP. (eds) Bildverarbeitung für die Medizin 2008. Informatik aktuell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-78640-5_17
Download citation
DOI: https://doi.org/10.1007/978-3-540-78640-5_17
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-78639-9
Online ISBN: 978-3-540-78640-5
eBook Packages: Computer Science and Engineering (German Language)