Skip to main content

Cardiac: Coronary Stents

  • Chapter
Book cover Dual Source CT Imaging

Abstract

Percutaneous coronary intervention (PCI) with stent placement is the leading technique for nonsurgical myocardial revascularization therapy. Despite a technical success rate of more than 95%, in-stent restenosis remains a major clinical problem. Restenosis rates of up to 46% have been described in patients receiving non-drug-eluting stents.1 Although the incidence of early in-stent restenosis may be significantly reduced when drug-eluting stents are employed, the early detection of restenosis is important to avoid recurrent myocardial ischemia and infarction and thus to improve the long-term prognosis after revascularization therapy. Furthermore, patients who previously underwent PCI often suffer from progression of atherosclerosis at other sites and may therefore require repeated imaging studies for the assessment of arterial patency. Currently conventional catheter coronary angiography remains the reference standard for the assessment of stent patency and overall for the evaluation of coronary artery stenosis. Due to its invasiveness, conventional coronary angiography is associated with rare but potentially serious side effects such as retroperitoneal bleeding, arterial rupture, myocardial infarction or stroke. Therefore, a non-invasive alternative for imaging of the coronary artery system would be highly desirable. Coronary magnetic resonance angiography is of limited value for the assessment of stent patency due to susceptibility artifacts generated by the metallic stent material, which usually obscures the stent lumen. Electron beam computed tomography (EBCT) has been employed for the display of coronary artery stents. However, EBCT does not allow the accurate visualization of the stent lumen and is therefore of limited value for the diagnosis of stent restenosis.2 Compared with EBCT, multi-detector computed tomography (MDCT) allows acquisition of image data with thinner slice thickness and less noise.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 14.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 19.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Kiemeneij F, Serruys PW, Macaya C, et al. Continued benefit of coronary stenting versus balloon angioplasty: five-year clinical follow-up of Benestent-I trial. J Am Coll Cardiol 2001; 37:1598–1603

    Article  PubMed  CAS  Google Scholar 

  2. Pump H, Mohlenkamp S, Sehnert CA, et al. Coronary arterial stent patency: assessment with electron-beam CT. Radiology 2000; 214:447–452

    PubMed  CAS  Google Scholar 

  3. Achenbach S, Giesler T, Ropers D, et al. Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography. Circulation 2001; 103:2535–2538

    PubMed  CAS  Google Scholar 

  4. Ligabue G, Rossi R, Ratti C, Favali M, Modena MG, Romagnoli R. Noninvasive evaluation of coronary artery stents patency after PTCA: role of Multislice Computed Tomography. Radiol Med (Torino) 2004; 108:128–137

    Google Scholar 

  5. Maintz D, Seifarth H, Flohr T, et al. Improved coronary artery stent visualization and in-stent stenosis detection using 16-slice computed-tomography and dedicated image reconstruction technique. Invest Radiol 2003; 38:790–795

    PubMed  Google Scholar 

  6. Lell M, Panknin C, Ruehm S, et al. Evaluation of coronary stents and stenoses at different heart rates with dual source spiral CT (DSCT). Invest Radiol. 2007 Jul;42(7):536–41

    Article  PubMed  Google Scholar 

  7. Maintz D, Seifarth H, Raupach R, et al. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents. Eur Radiol 2006; 16:818–826

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Peter R. Seidensticker MD Lars K. Hofmann MD

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer Medizin Verlag Heidelberg

About this chapter

Cite this chapter

Ruehm, S.G., Arellano, C., Panknin, C. (2008). Cardiac: Coronary Stents. In: Seidensticker, P.R., Hofmann, L.K. (eds) Dual Source CT Imaging. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-77602-4_4

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-77602-4_4

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-77601-7

  • Online ISBN: 978-3-540-77602-4

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics