Skip to main content

Part of the book series: IFMBE Proceedings ((IFMBE,volume 18))

  • 53 Accesses

Abstract

A new hearing screening semi-automatic system based on Multiple Auditory Steady-State Responses (MSSR) technique is presented here. It was implemented using the integrated development environment Delphi 7, and the specialized hardware AUDIX V (Neuronic S.A., Havana). For the MSSR testing we use a pre-set screening protocol and a semiautomatic algorithm. It was designed to be user-friendly and easy to operate for non-professionals, providing objective PASS/FAIL results that require no interpretation. This system can be a valid alternative for early detection of hearing impairments, and propose a methodology for a further development of fully automated screening equipment.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Referencias

  1. De Villiers, P.A. (1992). Educational implications of deafness: Language and literacy. In Eavey, R.D. Klein, J.O. (Eds.), Hearing Loss in Childhood: A Primer. Report of the 102nd Ross Conference on Pediatric Research (pp. 127–135). Columbus, OH: Ross Laboratories.

    Google Scholar 

  2. Pérez-Abalo, M.C. Gaya, J.A. Savio, G. Ponce de Leon, M. Perera, M, Reigosa, V. (2005). Early detection and intervention of hearing impairment in Cuba: Outcome after 20 years, Rev Neurol, 41, 556–563.Peters, J.G. (1986). An automated infant screener using advanced evoked response technology. Hear J, 39, 25–30.

    Google Scholar 

  3. Hall, J.W. Kileny, P.R. Ruth, R.A. Peters, K.J. (1987). Newborn auditory screening with Algo-I vs. conventional auditory brainstem response. Presented at the American Speech-Language-Hearing Association Meeting, New Orlans LA, 15–11.

    Google Scholar 

  4. Jacobson, J.T. Jacobson, C.A. Spahr, R.C. (1990). Automated and conventional ABR screening techniques in high-risk infants. J Am Acad Audiol, 1, 187–195.

    Google Scholar 

  5. Gravel J, Berg A, Bradley M, Cacace A, Campbell D, Dalzell L, DeCristofaro J, Greenberg E, Gross S, Orlando M, Pinheiro J, Regan J, Spivak L, Stevens F, Prieve B. (2000). New York State universal newborn hearing screening demonstration project: effects of screening protocol on inpatient outcome measures. Ear Hear, 21, 131–140.

    Article  Google Scholar 

  6. Sohmer, H. Feinmesser, M. (1967). Cochlear action potentials recorded from the external ear in man. Ann Otol Rhinol Laryngol, 76, 427–436.

    Google Scholar 

  7. Jewett, D.l. Willinston, J.S. (1971). Auditory-evoked far fields averaged from the scalp of humans. Brain, 94, 681–96.

    Article  Google Scholar 

  8. Kemp, D.T. (1978). Stimulated acoustic emissions from within the human auditory system. J Acoust Soc Am, 64, 1386–91.

    Article  Google Scholar 

  9. Norton, S.J. Gorga, M.P. Widen, J.E. Folsom, R.C. Sininger, Y. Cone-Wesson, B. Vohr, B.R. Mascher, K. Fletcher, K. (2000). Identification of neonatal hearing impairment: Evaluation of transient evoked otoacustic emission, distortion product otoacustic emission, and auditory brain stem response test performance. Ear Hear, 21, 508–528.

    Article  Google Scholar 

  10. Pérez-Abalo, M.C. Savio, G. Torres, A. Martin, V. Rodríguez, E. Galán, L. (2001). Steady state responses to multiple amplitude modulated tones: An optimized method to test frequency specific thresholds in hearing impaired children and normal subjects. Ear Hear, 22, 200–211.

    Article  Google Scholar 

  11. Herdman, A.T., Stapells, D.R. (2003). Auditory steady-state response thresholds of adults with sensorineural hearing impairments. International Journal of Audiology, 42, 237–248.

    Article  Google Scholar 

  12. Savío, G. Cardenas, J. Pérez-Abalo, M.C. Gonzáles, A. Valdes, M.C. (2001). The low and high frequency auditory steady state responses mature at different rates. Audiology and Neurootology, 6, 279–287.

    Article  Google Scholar 

  13. Luts, H. Desloovere, C. Wouters, J. (2006). Clinical application of dichotic multiple stimulus auditory steady state responses in high risk newborns and young children. Audiology and Neurotology, 11, 24–37.

    Article  Google Scholar 

  14. Torres, A. Pérez-Abalo, M.C. Rioja, L. Rodríguez, E. De Armas, J.L. Eimil, E. Savio, G. Muxo, V. Martín, V. (2003). Nueva versión en Windows del sistema AUDIX para la evaluación objetiva de la audición. [enlinea]. Auditio: Revista electrónica de audiología. 1 Febrero 2003, vol. 2(1), pp. 3–9. (http://www.auditio.com/revista/pdf/vol2/1/020102.pdf)

    Google Scholar 

  15. Valdés, J.L. Pérez-Abalo, M.C. Martín, V. Savio, G. Sierra, C. Rodríguez, E. (1997). Comparison of statistical indicators for the automatic detection of 80 Hz auditory steady state response. Ear Hear, 18, 420–429.

    Article  Google Scholar 

  16. John, M.S., Dimitrijevic, A., Picton, T.W. (2002). Auditory steady-state responses to exponential modulation envelopes. Ear Hear, 23, 106–117.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2007 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Santos Febles, E., Pérez-Abalo, M.C. (2007). Sistema semi-automático para el pesquisaje auditivo en recién nacidos sobre el electroaudiometro Audix V. In: Müller-Karger, C., Wong, S., La Cruz, A. (eds) IV Latin American Congress on Biomedical Engineering 2007, Bioengineering Solutions for Latin America Health. IFMBE Proceedings, vol 18. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-74471-9_29

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-74471-9_29

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-74470-2

  • Online ISBN: 978-3-540-74471-9

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics