Skip to main content

Part of the book series: IFMBE Proceedings ((IFMBE,volume 18))

  • 90 Accesses

Abstract

In this work we considered to take the obtained data from basic a cardiac monitor and by means of the use from digital signal processing (DSP) to come to improve the characteristics and benefits of the same one. This monitor was developed as didactic-experimental equipment in the Laboratory of Bioelectrónica of the Department of Electronic Engineering of the Technological University National Regional Faculty Cordoba is a device of under cost able to acquire the twelve derivations with three simultaneously. Its structure consists of a block analogical, that the function fulfills to acquire and to prepare the signal of the ECG, and a digital stage, that turns the analogical values to words digital which are processed with DSP techniques. In this work they evaluated the use of diverse digital filters, in aspects such as, run time, conditions for its implementation, amount and type of variables. On the other hand it was come to compare the result of the implementation of these techniques with the data obtained without her. The final equipment is a monitor, portable electrocardiograph and of low cost, able to be implemented with different configurations from digital filters or without them, all it with the purpose of allowing to its application in the degree education, postdegree and applied investigation.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Referencias

  1. Willis J Tompkins “Biomedical digital signal processing” 1997.Editorial Prentice Hall año1993 isbn 0-13-067216-5

    Google Scholar 

  2. Microchip, “PIC-Complete Mid-Range Reference”. Web Microchip

    Google Scholar 

  3. Shoichiro Nakamura, “Análisis numérico y visualización gráfica con Matlab”, Prentice Hall-1997-isbn 968-880-860-1

    Google Scholar 

  4. Delors, M.Etter “Solucion de Problemas de Ingeniería con Matlab” [1] Prentice Hall-1997 — isbn 970-17-0111-9

    Google Scholar 

  5. Deitel & Deitel, “Como programar con C/C++”. Prentice Hall-1995 isbn 968-880-471-1

    Google Scholar 

  6. Coughlin, Robert, “Amplificadores Operacionales y Circuitos” Prentice Hall — 1999 — isbn 970-17-0267-0

    Google Scholar 

  7. Del Aguila, “Electromedicina” Hasa — 1994-isbn 950-528-113-7

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2007 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Centeno, C.A., Gonzalez, E., Cagnolo, F., Olmos, C. (2007). Procesamiento Digital sobre Monitor Cardíaco. In: Müller-Karger, C., Wong, S., La Cruz, A. (eds) IV Latin American Congress on Biomedical Engineering 2007, Bioengineering Solutions for Latin America Health. IFMBE Proceedings, vol 18. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-74471-9_116

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-74471-9_116

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-74470-2

  • Online ISBN: 978-3-540-74471-9

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics